A chemometric study of active parameters and their interaction effects in a nebulized sheath-liquid electrospray interface for capillary electrophoresis-mass spectrometry

被引:27
作者
Nilsson, SL
Bylund, D
Jörntén-Karlsson, M
Petersson, P
Markides, KE
机构
[1] Uppsala Univ, Dept Analyt Chem, SE-75124 Uppsala, Sweden
[2] Mid Sweden Univ, Dept Nat & Environm Sci, Sundsvall, Sweden
[3] AstraZeneca R&D, Lund, Sweden
关键词
capillary electrophoresis; chemometrics; electrospray; interaction effects; mass spectrometry;
D O I
10.1002/elps.200305937
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A chemometrics approach has been used for evaluating the effect of four experimental parameters when coupling capillary electrophoresis (CE) to electrospray ionization-mass spectrometry (ESI-MS). Electrospray voltage, sheath-liquid flow rate, nebulizing gas flow rate, and spray needle position in respect to the MS orifice were varied according to a full factorial design. In addition to main effects, two interaction effects could be identified as significant when measuring the peak intensity of the analytes, from a sample mixture containing peptides and pharmaceuticals. The first interaction effects, between the nebulizing gas flow rate and the sheath-liquid flow rate, and the second interaction effect, between the nebulizing gas flow rate and the spray position, could further explain the impact that these variables have on the spray performance. The number of theoretical plates and the baseline noise were also measured. The sheath-liquid flow was found to significantly affect the separation efficiency, while the noise level mainly was controlled by the nebulizing gas flow. The same factorial design was also used for a CE capillary with lower internal diameter (ID) and the effects of the same variables were compared on those capillaries using equal injection volume for both capillaries. Similar trends were obtained in both capillaries but capillary ID was shown to be a significant variable when evaluating both capillaries in a single model. It was found that a capillary with 25 mum ID provided improved CE-MS performance over than corresponding 50 mum ID capillary. Enhanced sensitivity was obtained using the narrow-bore capillary, and at lower sheath-liquid flow rate the 25 mum ID capillary also gave rise to more efficient peaks.
引用
收藏
页码:2100 / 2107
页数:8
相关论文
共 22 条
[1]   Detection of fast capillary electrophoresis peptide and protein separations using electrospray ionization with a time-of-flight mass spectrometer [J].
Banks, JF ;
Dresch, T .
ANALYTICAL CHEMISTRY, 1996, 68 (09) :1480-1485
[2]  
BANKS JF, 1995, J CHROMATOGR A, V712, P245
[3]  
de la Mora JF, 2000, J MASS SPECTROM, V35, P939
[4]   Advances in CE MS [J].
Ding, JM ;
Vouros, P .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :378A-385A
[5]  
ERKISSON L, 2000, DESIGN EXPT PRINCIPL
[6]   EFFECT OF TEMPERATURE-GRADIENTS ON THE EFFICIENCY OF CAPILLARY ZONE ELECTROPHORESIS SEPARATIONS [J].
GRUSHKA, E ;
MCCORMICK, RM ;
KIRKLAND, JJ .
ANALYTICAL CHEMISTRY, 1989, 61 (03) :241-246
[7]   QUANTITATIVE CAPILLARY ELECTROPHORESIS ION SPRAY MASS-SPECTROMETRY ON A BENCHTOP ION-TRAP FOR THE DETERMINATION OF ISOQUINOLINE ALKALOIDS [J].
HENION, JD ;
NLORDEHAI, AV ;
CAI, JY .
ANALYTICAL CHEMISTRY, 1994, 66 (13) :2103-2109
[8]   Effects of nebulizing and drying gas flow on capillary electrophoresis/mass spectrometry [J].
Huikko, K ;
Kotiaho, T ;
Kostiainen, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (16) :1562-1568
[9]   Capillary electrophoresis-electrospray ion-trap mass spectrometry for the separation of chlorophenols [J].
Jáuregui, O ;
Moyano, E ;
Galceran, MT .
JOURNAL OF CHROMATOGRAPHY A, 2000, 896 (1-2) :125-133
[10]  
KEBARLE P, 1997, ELECTROSPRAY IONIZAT, pCH1