Design of photoionization detector based on the miniature gas chromatography

被引:1
作者
Chai Shou-chen [1 ]
Yang Peng [1 ]
Yang Cheng-jia
Cai Chun-li [1 ]
Yu Na [1 ]
机构
[1] China Elect Technol Grp Corp 49th Res Inst, Harbin 150001, Heilongjiang, Peoples R China
来源
COMPUTING, CONTROL AND INDUSTRIAL ENGINEERING IV | 2013年 / 823卷
关键词
photoionization detector; ionization chamber; sensitivity; detection limit;
D O I
10.4028/www.scientific.net/AMR.823.291
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the space restricted airtight environment that people lives in, detecting harmful gas by miniature gas chromatography is the practical requirement at present, however, PID's performance is key factor that restrict the application of miniature gas chromatography, the redesign of the detector's gas route in this paper aiming at improve detector's stability observably, and schemed out miniature PID with high sensitivity, low detection limit and fast response. The result of the experiment shows that the detection limit is 0.04ppm, the sensitivity is 101mv/ppm,the stability is 0.04x10-6/24h,meeting the project requirement.
引用
收藏
页码:291 / +
页数:2
相关论文
共 50 条
[21]   Determination of short-term exposure with a direct reading photoionization detector [J].
Poirot, P ;
Subra, I ;
Gérardin, F ;
Baudin, V ;
Grossmann, S ;
Héry, M .
ANNALS OF OCCUPATIONAL HYGIENE, 2004, 48 (01) :75-84
[22]   Design of a Gas Sensor for Hydrazines Based on Photo-ionization Principle [J].
Liu, Jun ;
Tan, Qiulin ;
Xue, Chenyan ;
Xiong, Jijun .
FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE, PTS 1-4, 2011, 44-47 :2050-+
[23]   Design and Application of A Novel Photo Ionization Detector [J].
Wang Hai-Long ;
Cao Xiu-Jun ;
Bao Chun ;
Meng Zong-Bao ;
Zhao Guo-Xing ;
Sun Sheng-Kun .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (10) :1513-1516
[24]   Study of electrode pattern design for a CZT-based PET detector [J].
Gu, Y. ;
Levin, C. S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11) :2599-2621
[25]   Positive Effect of Acetylation on Proteomic Analysis Based on Liquid Chromatography with Atmospheric Pressure Chemical Ionization and Photoionization Mass Spectrometry [J].
Sedlackova, Simona ;
Hubalek, Martin ;
Vrkoslav, Vladimir ;
Blechova, Miroslava ;
Kozlik, Petr ;
Cvacka, Josef .
MOLECULES, 2023, 28 (09)
[26]   Multiple-detector responses or multiple-retention times: what is more informative for gas chromatography peak identification? [J].
Stoev, G ;
Mihailova, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1047 (02) :263-269
[27]   A Gas Chromatography Flame Ionization Detector Method for Rapid Simultaneous Separation and Determination of Six Active Ingredients of Anticold Drug [J].
Yang, Fatang ;
Du, Xiaoyun ;
Wang, Zhen ;
Dong, Yuming .
CURRENT PHARMACEUTICAL ANALYSIS, 2022, 18 (01) :71-81
[28]   Chemicapacitors as a versatile platform for miniature gas and vapor sensors [J].
Blue, Robert ;
Uttamchandani, Deepak .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (02)
[29]   Optimization design of Compton detector [J].
Li Q. ;
Liu J. .
Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2010, 22 (03) :635-638
[30]   Windowless pulsed-discharge photoionization detector - Application to qualitative analysis of volatile organic compounds [J].
Gremaud, G ;
Wentworth, WE ;
Zlatkis, A ;
Swatloski, R ;
Chen, ECM ;
Stearns, SD .
JOURNAL OF CHROMATOGRAPHY A, 1996, 724 (1-2) :235-250