Design of photoionization detector based on the miniature gas chromatography

被引:1
|
作者
Chai Shou-chen [1 ]
Yang Peng [1 ]
Yang Cheng-jia
Cai Chun-li [1 ]
Yu Na [1 ]
机构
[1] China Elect Technol Grp Corp 49th Res Inst, Harbin 150001, Heilongjiang, Peoples R China
来源
COMPUTING, CONTROL AND INDUSTRIAL ENGINEERING IV | 2013年 / 823卷
关键词
photoionization detector; ionization chamber; sensitivity; detection limit;
D O I
10.4028/www.scientific.net/AMR.823.291
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
In the space restricted airtight environment that people lives in, detecting harmful gas by miniature gas chromatography is the practical requirement at present, however, PID's performance is key factor that restrict the application of miniature gas chromatography, the redesign of the detector's gas route in this paper aiming at improve detector's stability observably, and schemed out miniature PID with high sensitivity, low detection limit and fast response. The result of the experiment shows that the detection limit is 0.04ppm, the sensitivity is 101mv/ppm,the stability is 0.04x10-6/24h,meeting the project requirement.
引用
收藏
页码:291 / +
页数:2
相关论文
共 50 条
  • [1] An improved photoionization detector with a micro gas chromatography column for portable rapid gas chromatography system
    Sun, Jianhai
    Guan, Fengying
    Cui, Dafu
    Chen, Xing
    Zhang, Lulu
    Chen, Jian
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 513 - 518
  • [2] Colorimetric Readout Based Photoionization Detector for Gas Chromatographs
    Mao, Jingqin
    Liu, Longze
    Atwa, Yahya
    Hou, Junming
    Shakeel, Hamza
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2024, 19 (05) : 845 - 851
  • [3] Design of the Photoionization Detector for the Detection of Volatile Organic Compounds
    Sun Ruixia
    Liang Ting
    Fan Qiusheng
    Tan Qiulin
    Liu Jun
    ISTM/2009: 8TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, 2009, : 2317 - 2320
  • [4] SELECTIVE DETERMINATION OF TRACE ARSENIC AND ANTIMONY SPECIES IN NATURAL-WATERS BY GAS-CHROMATOGRAPHY WITH A PHOTOIONIZATION DETECTOR
    YAMAMOTO, M
    TANAKA, S
    HASHIMOTO, Y
    APPLIED ORGANOMETALLIC CHEMISTRY, 1992, 6 (04) : 351 - 356
  • [5] A rapid photoionization detector-based gas chromatography electronic nose enhanced by DOE and SVM for accurate classification of baijiu jiuqu quality grades
    Mao, Yuezhong
    Fang, Lining
    Ye, Xiao
    Shi, Shuangni
    Qin, Yumei
    Qin, Zihan
    Cao, Yanyun
    Jiang, Guoxin
    Tian, Shiyi
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2025, 140
  • [6] Subsurface detection of fossil fuel pollutants by photoionization and gas chromatography/mass spectrometry
    Robbat, Albert, Jr.
    Considine, Thomas
    Antle, Patrick M.
    CHEMOSPHERE, 2010, 80 (11) : 1370 - 1376
  • [7] A helium ionization detector with a thermionic electron emitter for gas chromatography
    Yu. A. Saprykin
    V. M. Tsmots’
    M. V. Tsyuper
    Yu. A. Pazderskii
    Journal of Analytical Chemistry, 2009, 64 : 277 - 281
  • [8] Characterization of a modular microfluidic photoionization detector
    Rezende, Gustavo Coelho
    Le Calve, Stephane
    Brandner, Jurgen J.
    Newport, David
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 324
  • [9] Principle of Comprehensive Calibration of a Portable Gas Chromatograph with a Photoionization Detector for Geochemical Prospecting of Hydrocarbon Deposits
    M. N. Baldin
    V. M. Gruznov
    Journal of Analytical Chemistry, 2025, 80 (1) : 154 - 160
  • [10] High-Sensitivity Micro-Gas Chromatograph-Photoionization Detector for Trace Vapor Detection
    Li, Maxwell Wei-Hao
    Ghosh, Abhishek
    Venkatasubramanian, Anandram
    Sharma, Ruchi
    Huang, Xiaolu
    Fan, Xudong
    ACS SENSORS, 2021, 6 (06) : 2348 - 2355