Surgically Relevant Localization of the Central Sulcus With High-Density Somatosensory-Evoked Potentials Compared With Functional Magnetic Resonance Imaging

被引:23
作者
Lascano, Agustina M. [1 ]
Grouiller, Frederic [2 ,3 ,4 ]
Genetti, Melanie [1 ,2 ,3 ]
Spinelli, Laurent [1 ]
Seeck, Margitta [1 ]
Schaller, Karl [5 ]
Michel, Christoph M. [1 ,2 ,3 ]
机构
[1] Univ Hosp Geneva, Dept Neurol, Geneva, Switzerland
[2] Univ Hosp Geneva, Dept Neurol, Funct Brain Mapping Lab, Geneva, Switzerland
[3] Ctr Med Univ Geneva, Geneva, Switzerland
[4] Univ Hosp Geneva, Dept Radiol & Med Informat, Geneva, Switzerland
[5] Univ Hosp Geneva, Dept Neurosurg, Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
Electrical source imaging; Electroencephalography; Eloquent cortex; Functional imaging; Presurgical evaluation; Primary somatosensory cortex; ELECTRIC SOURCE LOCALIZATION; MONTE-CARLO-SIMULATION; DIPOLE LOCALIZATION; TACTILE STIMULATION; PRECENTRAL GYRUS; CORTEX; EEG; ACTIVATION; FMRI; ELECTROENCEPHALOGRAPHY;
D O I
10.1227/NEU.0000000000000298
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Resection of abnormal brain tissue lying near the sensorimotor cortex entails precise localization of the central sulcus. Mapping of this area is achieved by applying invasive direct cortical electrical stimulation. However, noninvasive methods, particularly functional magnetic resonance imaging (fMRI), are also used. As a supplement to fMRI, localization of somatosensory-evoked potentials (SEPs) recorded with an electroencephalogram (EEG) has been proposed, but has not found its place in clinical practice. OBJECTIVE: To assess localization accuracy of the hand somatosensory cortex with SEP source imaging. METHODS: We applied electrical source imaging in 49 subjects, recorded with high-density EEG (256 channels). We compared it with fMRI in 18 participants and with direct cortical electrical stimulation in 6 epileptic patients. RESULTS: Comparison of SEP source imaging with fMRI indicated differences of 3 to 8 mm, with the exception of the mesial-distal orientation, where variances of up to 20 mm were found. This discrepancy is explained by the fact that the source maximum of the first SEP peak is localized deep in the central sulcus (area 3b), where information initially arrives. Conversely, fMRI showed maximal signal change on the lateral surface of the postcentral gyrus (area 1), where sensory information is integrated later in time. Electrical source imaging and fMRI showed mean Euclidean distances of 13 and 14 mm, respectively, from the contacts where electrocorticography elicited sensory phenomena of the contralateral upper limb. CONCLUSION: SEP source imaging, based on high-density EEG, reliably identifies the depth of the central sulcus. Moreover, it is a simple, flexible, and relatively inexpensive alternative to fMRI.
引用
收藏
页码:517 / 526
页数:10
相关论文
共 59 条
[1]   HUMAN CORTICAL POTENTIALS-EVOKED BY STIMULATION OF THE MEDIAN NERVE .1. CYTOARCHITECTONIC AREAS GENERATING SHORT-LATENCY ACTIVITY [J].
ALLISON, T ;
MCCARTHY, G ;
WOOD, CC ;
DARCEY, TM ;
SPENCER, DD ;
WILLIAMSON, PD .
JOURNAL OF NEUROPHYSIOLOGY, 1989, 62 (03) :694-710
[2]   Multimodal image coregistration and partitioning - A unified framework [J].
Ashburner, J ;
Friston, K .
NEUROIMAGE, 1997, 6 (03) :209-217
[3]   Academic Software Applications for Electromagnetic Brain Mapping Using MEG and EEG [J].
Baillet, Sylvain ;
Friston, Karl ;
Oostenveld, Robert .
COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2011, 2011
[4]   Combined EEG and MEG analysis of early somatosensory evoked activity in children and adolescents with focal epilepsies [J].
Bast, T. ;
Wright, T. ;
Boor, R. ;
Harting, I. ;
Feneberg, R. ;
Rupp, A. ;
Hoechstetter, K. ;
Rating, D. ;
Baumgaertner, U. .
CLINICAL NEUROPHYSIOLOGY, 2007, 118 (08) :1721-1735
[5]   SOMATOTOPY OF HUMAN HAND SOMATOSENSORY CORTEX AS STUDIED IN SCALP EEG [J].
BAUMGARTNER, C ;
DOPPELBAUER, A ;
SUTHERLING, WW ;
LINDINGER, G ;
LEVESQUE, MF ;
AULL, S ;
ZEITLHOFER, J ;
DEECKE, L .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 88 (04) :271-279
[6]   Electroencephalographic source imaging: a prospective study of 152 operated epileptic patients [J].
Brodbeck, Verena ;
Spinelli, Laurent ;
Lascano, Agustina M. ;
Wissmeier, Michael ;
Vargas, Maria-Isabel ;
Vulliemoz, Serge ;
Pollo, Claudio ;
Schaller, Karl ;
Michel, Christoph M. ;
Seeck, Margitta .
BRAIN, 2011, 134 :2887-2897
[7]   Accuracy of EEG source imaging of epileptic spikes in patients with large brain lesions [J].
Brodbeck, Verena ;
Lascano, Agustina M. ;
Spinelli, Laurent ;
Seeck, Margitta ;
Michel, Christoph M. .
CLINICAL NEUROPHYSIOLOGY, 2009, 120 (04) :679-685
[8]   Spatiotemporal Analysis of Multichannel EEG: CARTOOL [J].
Brunet, Denis ;
Murray, Micah M. ;
Michel, Christoph M. .
COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2011, 2011
[9]   SOMATOTOPY OF HUMAN HAND SOMATOSENSORY CORTEX REVEALED BY DIPOLE SOURCE ANALYSIS OF EARLY SOMATOSENSORY-EVOKED POTENTIALS AND 3D-NMR TOMOGRAPHY [J].
BUCHNER, H ;
ADAMS, L ;
MULLER, A ;
LUDWIG, I ;
KNEPPER, A ;
THRON, A ;
NIEMANN, K ;
SCHERG, M .
EVOKED POTENTIALS-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1995, 96 (02) :121-134
[10]   Simultaneous electroencephalography and functional magnetic resonance imaging of primary and secondary somatosensory cortex in humans after electrical stimulation [J].
Christmann, C ;
Ruf, M ;
Braus, DF ;
Flor, H .
NEUROSCIENCE LETTERS, 2002, 333 (01) :69-73