Coordinated Direct Power Control of DFIG System Without Phase-Locked Loop Under Unbalanced Grid Voltage Conditions

被引:106
作者
Nian, Heng [1 ]
Cheng, Peng [1 ]
Zhu, Z. Q. [2 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Zhejiang, Peoples R China
[2] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
关键词
Coordinated direct power control; doubly fed induction generator (DFIG); phase-locked loop (PLL); single-side resonant controller; unbalanced grid voltage; FED INDUCTION GENERATOR; WIND TURBINE; CONVERTERS; OPERATION;
D O I
10.1109/TPEL.2015.2453127
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a coordinated direct power control (DPC) scheme for the rotor-side converter (RSC) and the grid-side converter (GSC) of the doubly fed induction generator (DFIG) under unbalanced grid voltage conditions. In order to eliminate the coupling interactions between the phase-locked loop (PLL) and the local unbalanced network, a virtual phase angle is used to replace the actual one acquired by the PLL. Thus, the PLL is removed out of RSC and GSC in the proposed DPC scheme. During network unbalance, the RSC is controlled to reduce torque ripples, while three selectable control targets are identified for the GSC, i.e., constant total active power, constant total reactive power, and balanced currents. A single-side resonant controller with the frequency discrimination between the positive- and negative-sequence signals of the same frequency is employed in the coordinated DPC scheme to avoid the complex calculations of the power compensating components. Meanwhile, the sequential separations of the voltages and currents are also eliminated. Then, the control performance, including the limits of the dc-link voltage, the dc-capacitor power oscillations, the impacts of the frequency deviations, and the grid synchronization of the proposed DPC strategy, is discussed. Finally, the experimental results of DFIG system verify the effectiveness of the proposed DPC strategy under unbalanced grid voltage conditions.
引用
收藏
页码:2905 / 2918
页数:14
相关论文
共 32 条
[1]   Current Controller Based on Reduced Order Generalized Integrators for Distributed Generation Systems [J].
Alberto Busada, Claudio ;
Gomez Jorge, Sebastian ;
Leon, Andres E. ;
Solsona, Jorge A. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (07) :2898-2909
[2]  
[Anonymous], 2002, 61000222002 IEC
[3]  
[Anonymous], 2008, 159452008 GBT
[4]  
[Anonymous], 2012, 199632011 GBT
[5]   Future on Power Electronics for Wind Turbine Systems [J].
Blaabjerg, Frede ;
Ma, Ke .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2013, 1 (03) :139-152
[6]   Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters [J].
Cespedes, Mauricio ;
Sun, Jian .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1254-1261
[7]   Collaborative Control of DFIG System During Network Unbalance Using Reduced-Order Generalized Integrators [J].
Cheng, Peng ;
Nian, Heng .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2015, 30 (02) :453-464
[8]   Modeling and Design of Islanding Detection Using Phase-Locked Loops in Three-Phase Grid-Interface Power Converters [J].
Dong, Dong ;
Wen, Bo ;
Mattavelli, Paolo ;
Boroyevich, Dushan ;
Xue, Yaosuo .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2014, 2 (04) :1032-1040
[9]  
Energinet, 2004, GRID CONN WIND TURB
[10]   Instability of Wind Turbine Converters During Current Injection to Low Voltage Grid Faults and PLL Frequency Based Stability Solution [J].
Goksu, Omer ;
Teodorescu, Remus ;
Bak, Claus Leth ;
Iov, Florin ;
Kjaer, Philip Carne .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2014, 29 (04) :1683-1691