Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping

被引:382
作者
Bao, Chenlei [1 ]
Ruan, Xinbo [1 ,2 ]
Wang, Xuehua [1 ]
Li, Weiwei [1 ]
Pan, Donghua [1 ]
Weng, Kailei [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Aeropower Sci Tech Ctr, Nanjing 210016, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; controller design; grid-connected inverter; LCL filter; single-phase; VOLTAGE-SOURCE CONVERTER; H-INFINITY CONTROL; PWM CONVERTERS; FILTER; SUPPRESSION; DISTORTION; STABILITY;
D O I
10.1109/TPEL.2013.2262378
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The injected grid current regulator and active damping of the LCL filter are essential to the control of LCL-type grid-connected inverters. Generally speaking, the current regulator guarantees the quality of the injected grid current, and the active damping suppresses the resonance peak caused by the LCL filter and makes it easier to stabilize the whole system. Based on the proportional-integral (PI) and proportional-resonant (PR) compensator together with capacitor-current-feedback active-damping which are widely used for their effectiveness and simple implementations, this paper proposes a simple step-by-step controller design method for the LCL-type grid-connected inverter. By carefully dealing with the interaction between the current regulator and active damping, the complete satisfactory regions of the controller parameters for meeting the system specifications are obtained, and from which the controller parameters can be easily picked out. Based on these satisfactory regions, it is more convenient and explicit to optimize the system performance. Besides, the insight of tuning the controller parameters from these satisfactory regions is also discussed. Simulation and experimental results verify the proposed step-by-step design method.
引用
收藏
页码:1239 / 1253
页数:15
相关论文
共 44 条
  • [1] Suppression of line voltage related distortion in current controlled grid connected inverters
    Abeyasekera, T
    Johnson, CM
    Atkinson, DJ
    Armstrong, M
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2005, 20 (06) : 1393 - 1401
  • [2] A Modified Stationary Reference Frame-Based Predictive Current Control With Zero Steady-State Error for LCL Coupled Inverter-Based Distributed Generation Systems
    Ahmed, Khaled H.
    Massoud, Ahmed M.
    Finney, Stephen J.
    Williams, Barry W.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (04) : 1359 - 1370
  • [3] [Anonymous], 6172011 QGDW
  • [4] [Anonymous], 2000, 9292000 IEEE
  • [5] [Anonymous], THESIS MONASH U VICT
  • [6] [Anonymous], IEEE T IND ELECT
  • [7] Overview of control and grid synchronization for distributed power generation systems
    Blaabjerg, Frede
    Teodorescu, Remus
    Liserre, Marco
    Timbus, Adrian V.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1398 - 1409
  • [8] A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter
    Blasko, V
    Kaura, V
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1997, 33 (02) : 542 - 550
  • [9] Buso S., 2006, DIGITALCONTROL POWER
  • [10] Dahono P. A., 2001, 4th IEEE International Conference on Power Electronics and Drive Systems. IEEE PEDS 2001 - Indonesia. Proceedings (Cat. No.01TH8594), P403, DOI 10.1109/PEDS.2001.975347