摘要
Background: 99mTc-sestamibi (MIBI) parathyroid SPECT is generally regarded as the best preoperative localizing method in patients with hyperparathyroidism (HPT). However, 99mTc-MIBI SPECT is false negative in approximately 25% of adenomas. 11C-methionine positron emission tomography (PET) has been used in HPT with negative 99mTc-MIBI SPECT scan results. Purpose: To systematically review and conduct a meta-analysis of published data on the performance of 11C-methionine PET in patients with HPT with negative 99mTc-MIBI SPECT. Material and Methods: A comprehensive review of the literature was performed. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT and a negative 99mTc-MIBI SPECT was calculated on a per-patient basis using receiver-operating characteristic (ROC) methodology. Results: Nine studies that met all inclusion and exclusion criteria were included into our meta-analysis, comprising a total sample size of 137 patients. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT with negative or inconclusive 99mTc-MIBI SPECT scans was 86% and 86%, respectively. The area under the ROC curve was 0.87. Conclusion: By merit of the high overall sensitivity, specificity, and accuracy, 11C-methionine PET can potentially complement the diagnostic workup of patients with HPT and negative or inconclusive 99mTc-MIBI SPECT. 11C-methionine PET appears to be a promising diagnostic modality in complicated cases with HPT.
引用
收藏
页码:558 / 564
页数:7
相关论文
共 50 条
  • [1] 11C-Methionine PET/CT Imaging of 99mTc-MIBI-SPECT/CT-Negative Patients With Primary Hyperparathyroidism and Previous Neck Surgery
    Traub-Weidinger, Tatjana
    Mayerhoefer, Marius E.
    Koperek, Oskar
    Mitterhauser, Markus
    Duan, Heying
    Karanikas, Georgios
    Niederle, Bruno
    Hoffmann, Martha
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2014, 99 (11) : 4199 - 4205
  • [2] Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging
    Zhang, Zhining
    Zhao, Min
    Chen, Bin
    Cao, Yiming
    Gao, Shi
    JOURNAL OF CANCER, 2024, 15 (07): : 1863 - 1869
  • [3] Detection rate of 99mTc-MIBI single photon emission computed tomography (SPECT)/CT in preoperative planning for patients with primary hyperparathyroidism: A meta-analysis
    Treglia, Giorgio
    Sadeghi, Ramin
    Schalin-Jantti, Camilla
    Caldarella, Carmelo
    Ceriani, Luca
    Giovanella, Luca
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2016, 38 : E2159 - E2172
  • [4] 99mTc-MIBI SPECT/CT imaging contribution in the diagnosis of patients with hyperparathyroidism
    Nevena, Manevska
    Sinisa, Stojanoski
    Bojana, Stoilovska
    Irena, Sazdova
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 27 (01): : 1 - 7
  • [5] Comparison of pinhole and SPECT 99mTc-MIBI imaging in primary hyperparathyroidism
    Shon, Ivan A. Ho
    Yan, Warren
    Roach, Paul J.
    Bernard, Elizabeth J.
    Shields, Melissa
    Sywak, Mark
    Sidhu, Stanley
    Delbridge, Leigh W.
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (11) : 949 - 955
  • [6] 11C-methionine PET/CT in 99mTc-sestamibi-negative hyperparathyroidism in patients with renal failure on chronic haemodialysis
    Domenico Rubello
    Stefano Fanti
    Cristina Nanni
    Mohsen Farsad
    Paolo Castellucci
    Stefano Boschi
    Roberto Franchi
    Giuliano Mariani
    Lorraine M. Fig
    Milton D. Gross
    European Journal of Nuclear Medicine and Molecular Imaging, 2006, 33 : 453 - 459
  • [7] The Value of 99mTc-MIBI SPECT/CT in the Postoperative Assessment of Patients with Differentiated Thyroid Carcinoma
    Okudan, Berna
    Seven, Bedri
    Gulaldi, Nedim C. M.
    Capraz, Mustafa
    Acikgoz, Yusuf
    CURRENT MEDICAL IMAGING, 2022, 18 (04) : 404 - 408
  • [8] 11C-methionine PET/CT in 99mTc-sestamibi-negative hyperparathyroidism in patients with renal failure on chronic haemodialysis
    Rubello, D
    Fanti, S
    Nanni, C
    Farsad, M
    Castellucci, P
    Boschi, S
    Franchi, R
    Mariani, G
    Fig, LM
    Gross, MD
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (04) : 453 - 459
  • [9] Comparison of 99mTc-sestamibi and 11C-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism
    Martinez-Rodriguez, I.
    Martinez-Amador, N.
    de Arcocha-Torres, M.
    Quirce, R.
    Ortega-Nava, F.
    Ibanez-Bravo, S.
    Lavado-Perez, C.
    Bravo-Ferrer, Z.
    Carril, J. M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2014, 33 (02): : 93 - 98
  • [10] Factors associated with negative 99mTc-MIBI scanning in patients with primary hyperparathyroidism
    Carral, F.
    Jimenez, A., I
    Tome, M.
    Alvarez, J.
    Diez, A.
    Partida, F.
    Ayala, C.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2021, 40 (04): : 222 - 228