Quantitative determination of fenthion in pesticide formulations by FT-Raman spectroscopy

被引:29
作者
Skoulika, SG [1 ]
Georgiou, CA [1 ]
Polissiou, MG [1 ]
机构
[1] Univ Athens, Chem Lab, Athens 11855, Greece
基金
中国国家自然科学基金;
关键词
fenthion; FT-Raman; determination; pesticide formulations;
D O I
10.1366/0003702991945858
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Raman spectrum of the organophosphorus pesticide fenthion is presented, and a novel Fourier transform (FT)-Raman method for the quantitative determination of fenthion in pesticide formulations is proposed. Calibration curves based on Raman intensity and band area at 2951, 1065, 661, and 601 cm(-1) were linear (correlation coefficients: 0.991-0.998) in the concentration range of 0.4-4.36 M. Detection limits ranged between 0.14 to 0.36 M and precision from 0.4 to 6.8% relative standard deviation (RSD) (n = 4), Spectra normalization against the 802 cm(-1) cyclohexane band proved to be effective in minimizing the effect of excitation intensity fluctuations and sample positioning changes in calibration data, resulting in improved long-term stability of the calibration curves. Results obtained during the analysis of the Lebaycid formulation compare well with those obtained by the gas chromatography (GC) reference method. The proposed FT-Raman method Is fast, simple, and safe, avoids sample pretreatment, and minimizes handling of toxic samples.
引用
收藏
页码:1470 / 1474
页数:5
相关论文
共 25 条
[1]   SURFACE-ENHANCED RAMAN-SPECTROMETRY OF ORGANOPHOSPHORUS CHEMICAL-AGENTS [J].
ALAK, AM ;
VO-DINH, T .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :2149-2153
[2]   UV-vis, FT-Raman, and 1H NMR spectroscopies of cis-trans carotenoids from saffron (Crocus sativus L.) [J].
Assimiadis, MK ;
Tarantilis, PA ;
Polissiou, MG .
APPLIED SPECTROSCOPY, 1998, 52 (04) :519-522
[3]  
BARANSKA H, 1987, LASER RAMAN SPECTROM, pCH4
[4]  
BOWMAN JC, 1992, 9250 NIC
[5]   APPLICATION OF FOURIER-TRANSFORM RAMAN-SPECTROSCOPY TO A RANGE OF COMPOUNDS OF PHARMACEUTICAL INTEREST [J].
CUTMORE, EA ;
SKETT, PW .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 1993, 49 (5-6) :809-818
[6]   A highly sensitive, compact Raman system without a spectrometer for quantitative analysis of biological samples [J].
Dou, X ;
Yamaguchi, Y ;
Yamamoto, H ;
Doi, S ;
Ozaki, Y .
VIBRATIONAL SPECTROSCOPY, 1997, 14 (02) :199-205
[7]   Biological applications of anti-Stokes Raman spectroscopy: Quantitative analysis of glucose in plasma and serum by a highly sensitive multichannel Raman spectrometer [J].
Dou, XM ;
Yamaguchi, Y ;
Yamamoto, H ;
Uenoyama, H ;
Ozaki, Y .
APPLIED SPECTROSCOPY, 1996, 50 (10) :1301-1306
[8]  
Grasselli J.G., 1991, ANAL RAMAN SPECTROSC
[9]   RAPID GAS CHROMATOGRAPHIC ANALYSIS OF FRACTIONAL MICROGRAM CONCENTRATIONS OF LEBAYCID [J].
GUDZINOWICZ, BJ .
ANALYTICAL CHEMISTRY, 1965, 37 (03) :439-+
[10]   SPECTROPHOTOMETRIC MICRODETERMINATION OF LEBAYCID O,O-DIMETHYL-O-(4-)METHYLTHIO)-M-TOLYL)-PHOSPHOROTHIOATE [J].
HIRANO, Y ;
TAMURA, T .
ANALYTICAL CHEMISTRY, 1964, 36 (04) :800-&