A Tale of Two Compartments: Interstitial Versus Blood Glucose Monitoring

被引:251
作者
Cengiz, Eda [1 ]
Tamborlane, William V.
机构
[1] Yale Univ, Sch Med, Sect Pediat Endocrinol, New Haven, CT 06520 USA
关键词
STRATUM-CORNEUM; INSULIN; SYSTEM; TISSUE; SENSOR; ULTRASTRUCTURE; MICRODIALYSIS; HYPOGLYCEMIA; EXCURSIONS; ACCURACY;
D O I
10.1089/dia.2009.0002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Self-monitoring of blood glucose was described as one of the most important advancements in diabetes management since the invention of insulin in 1920. Recent advances in glucose sensor technology for measuring interstitial glucose concentrations have challenged the dominance of glucose meters in diabetes management, while raising questions about the relationships between interstitial and blood glucose levels. This article will review the differences between interstitial and blood glucose and some of the challenges in measuring interstitial glucose levels accurately.
引用
收藏
页码:S11 / S16
页数:6
相关论文
共 61 条
  • [1] A user-friendly method for calibrating a subcutaneous glucose sensor-based hypoglycaemic alarm
    Aussedat, B
    Thome-Duret, V
    Reach, G
    Lemmonier, F
    Klein, JC
    Hu, Y
    Wilson, GS
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (11) : 1061 - 1071
  • [2] Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
    Bantle, JP
    Thomas, W
    [J]. JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1997, 130 (04): : 436 - 441
  • [3] Bode Bruce, 2004, Diabetes Technol Ther, V6, P105, DOI 10.1089/152091504773731285
  • [4] Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor
    Boyne, MS
    Silver, DM
    Kaplan, J
    Saudek, CD
    [J]. DIABETES, 2003, 52 (11) : 2790 - 2794
  • [5] ULTRASTRUCTURE OF THE HUMAN DERMAL MICRO-CIRCULATION .3. THE VESSELS IN THE MID DERMIS AND LOWER DERMIS AND SUBCUTANEOUS FAT
    BRAVERMAN, IM
    KEHYEN, A
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1981, 77 (03) : 297 - 304
  • [6] ULTRASTRUCTURE OF HUMAN DERMAL MICROCIRCULATION .2. CAPILLARY LOOPS OF DERMAL PAPILLAE
    BRAVERMAN, IM
    YEN, A
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1977, 68 (01) : 44 - 52
  • [7] Optimal timing for postprandial glucose measurement in pregnant women with diabetes and a non-diabetic pregnant population evaluated by the Continuous Glucose Monitoring System (CGMS®)
    Bühling, KJ
    Winkel, T
    Wolf, C
    Kurzidim, B
    Mahmoudi, M
    Wohlfarth, K
    Wäscher, C
    Schink, T
    Dudenhausen, JW
    [J]. JOURNAL OF PERINATAL MEDICINE, 2005, 33 (02) : 125 - 131
  • [8] WHAT IS BLOOD-GLUCOSE - CAN IT BE MEASURED
    BURRIN, JM
    ALBERTI, KGMM
    [J]. DIABETIC MEDICINE, 1990, 7 (03) : 199 - 206
  • [9] Subcutaneous glucose sensor values closely parallel blood glucose during insulin-induced hypoglycaemia
    Caplin, NJ
    O'Leary, P
    Bulsara, M
    Davis, EA
    Jones, TW
    [J]. DIABETIC MEDICINE, 2003, 20 (03) : 238 - 241
  • [10] CHAN AYW, 1989, CLIN CHEM, V35, P315