Breast Reconstruction with Deep Inferior Epigastric Artery Perforator Flap: 3.0-T Gadolinium-enhanced MR Imaging for Preoperative Localization of Abdominal Wall Perforators

被引:43
作者
Chernyak, Victoria [1 ]
Rozenblit, Alla M. [1 ]
Greenspun, David T. [1 ]
Levine, Joshua L. [3 ]
Milikow, David L.
Chia, Frank A.
Erhard, Heather A. [2 ]
机构
[1] Montefiore Med Ctr, Dept Radiol, Bronx, NY 10467 USA
[2] Montefiore Med Ctr, Dept Plast Surg, Bronx, NY 10467 USA
[3] Ctr Microsurg Breast Reconstruct Manhattan Charle, New York, NY USA
关键词
ANGIOGRAPHY; EXPERIENCE;
D O I
10.1148/radiol.2501080307
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To prospectively evaluate 3.0-T gadolinium-enhanced magnetic resonance (MR) imaging for localization of inferior epigastric artery (IEA) perforators before reconstructive breast surgery involving a deep inferior epigastric perforator (DIEP) flap. Materials and Methods: This study was exempt from institutional review board approval, and the requirement for informed patient consent was waived. Data were collected and stored in compliance with HIPAA regulations. Nineteen patients (mean age, 46.3 years) underwent three-dimensional gadolinium-enhanced 3.0-T MR imaging of the abdomen before undergoing DIEP flap breast reconstruction. Up to four of the largest perforators arising from the IEA on each side of the umbilicus were identified. The diameter, intramuscular course, and distance from the umbilicus of each perforator were recorded. One of the marked perforators on each side was labeled "the best" on the basis of an optimal combination of perforator features: diameter, intramuscular course, and location with respect to the flap edges. MR findings were compared with intraoperative findings. The two-tailed Student t test was used to compare the mean diameters of all perforators with the mean diameters of the perforators labeled as the best. Results: There were 30 surgical flaps, and 11 (58%) of the 19 patients underwent bilateral flap dissection. At surgery, 122 perforators were localized, and 118 (97%) of these perforators-with a mean diameter of 1.1 mm (range, 0.8-1.6 mm)-had been identified at preoperative MR imaging. Thirty perforators with a mean diameter of 1.4 mm (range, 1.0-1.6 mm) were labeled as the best at MR imaging. Thirty-three perforators were harvested intraoperatively, and all of these had been localized preoperatively. Twenty-eight (85%) of these 33 perforators were labeled as the best at MR imaging. Conclusion: Gadolinium-enhanced 3.0-T MR imaging can be used to accurately localize IEA perforators and to select the optimal perforator to be harvested for DIEP flap reconstructive breast surgery. (C) RSNA, 2008
引用
收藏
页码:417 / 424
页数:8
相关论文
共 10 条
[1]   Preoperative planning of deep inferior epigastric artery perforator flap reconstruction with multislice-CT angiography:: imaging findings and initial experience [J].
Alonso-Burgos, A. ;
Garcia-Tutor, E. ;
Bastarrika, G. ;
Cano, D. ;
Martinez-Cuesta, A. ;
Pina, L. J. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2006, 59 (06) :585-593
[2]   The value of preoperative Doppler sonography for planning free perforator flaps [J].
Giunta, RE ;
Geisweid, A ;
Feller, AM .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 105 (07) :2381-2386
[3]   Bilateral breast reconstruction with the deep inferior epigastric perforator (DIEP) flap - An experience with 280 flaps [J].
Guerra, AB ;
Metzinger, SE ;
Bidros, RS ;
Rizzuto, RP ;
Gill, PS ;
Nguyen, AH ;
Dupin, CL ;
Allen, RJ .
ANNALS OF PLASTIC SURGERY, 2004, 52 (03) :246-252
[4]  
Howard Michael A, 2005, Int J Surg, V3, P53, DOI 10.1016/j.ijsu.2005.03.001
[5]   Differentiation of spinal cord arteries and veins by time-resolved MR angiography [J].
Jaspers, Karolien ;
Nijenhuis, Robbert J. ;
Backes, Walter H. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (01) :31-40
[6]   Multidetector-row computed tomography in the planning of abdominal perforator flaps [J].
Masia, J. ;
Clavero, J. A. ;
Larranaga, J. R. ;
Alomar, X. ;
Pons, G. ;
Serret, P. .
JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2006, 59 (06) :594-599
[7]  
Nijenhuis RJ, 2006, AM J NEURORADIOL, V27, P1565
[8]   Preoperative imaging for DIEA perforator flaps: A comparative study of computed tomographic angiography and Doppler ultrasound [J].
Rozen, Warren M. ;
Phillips, Timothy J. ;
Ashton, Mark W. ;
Stella, Damien L. ;
Gibson, Robert N. ;
Taylor, G. Ian .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 121 (01) :9-16
[9]  
Stewart S. L., 2007, Morbidity and Mortality Weekly Report, V56, P549
[10]   Risk factors for abdominal donor-site morbidity in free flap breast reconstruction [J].
Vyas, Raj M. ;
Dickinson, Brian P. ;
Fastekjian, Jaco H. ;
Watson, James P. ;
Dalio, Andrew L. ;
Crisera, Christopher A. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 121 (05) :1519-1526