Macrophage responses to a Zr-based bulk metallic glass

被引:12
作者
Huang, Lu [1 ]
Zhang, Tao [2 ]
Liaw, Peter K. [1 ]
He, Wei [1 ,3 ]
机构
[1] Univ Tennessee, Dept Mat Sci & Engn, Knoxville, TN 37996 USA
[2] Beihang Univ, Dept Mat Sci & Engn, Sch Mat Sci & Engn, Key Lab Aerosp Mat & Performance,Minist Educ, Beijing 100191, Peoples R China
[3] Univ Tennessee, Dept Mech Aerosp & Biomed Engn, Knoxville, TN 37996 USA
基金
美国国家科学基金会; 中国国家自然科学基金;
关键词
metallic glass; inflammation; macrophage; protein adsorption; cytokine; TITANIUM SURFACE-TOPOGRAPHY; NECROSIS-FACTOR-ALPHA; PROINFLAMMATORY CYTOKINES; TNF-ALPHA; CORROSION-FATIGUE; NITRIC-OXIDE; ACTIVATION; SECRETION; ADHESION; GROWTH;
D O I
10.1002/jbm.a.35009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bulk metallic glasses (BMGs) are considered to be a competitive candidate of biomedical materials, owing to their appealing mechanical properties and high thermal processability. Based on the established biosafety of the Zr-based BMGs, macrophage responses to (Zr55Al10Ni5Cu30)(99)Y-1 (atomic percent) BMG were investigated in the present study, in comparison with Ti-6Al-4V alloy. The adhesion of RAW 264.7 macrophages to both alloys was found to be mediated by protein adsorption. The Zr-based BMG is capable of supporting regular adhesion and proliferation of macrophages, indicating its good biocompatibility, which agrees with previous findings using other mammalian cells. A lower degree of morphological activation was revealed on Zr-based BMG substrates than on Ti-6Al-4V substrates, which is evidenced by smaller spreading areas and less ruffling on cell surfaces. Smaller amount of proinflammatory cytokine, tumor necrosis factor-alpha, was secreted by macrophages cultured on Zr-based BMGs, which further confirms the lower level of inflammation induced by BMG than by Ti alloys. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:3369 / 3378
页数:10
相关论文
共 62 条
[1]   Foreign body reaction to biomaterials [J].
Anderson, James M. ;
Rodriguez, Analiz ;
Chang, David T. .
SEMINARS IN IMMUNOLOGY, 2008, 20 (02) :86-100
[2]  
ANDERSON JM, 1984, BIOMATERIALS, V5, P5, DOI 10.1016/0142-9612(84)90060-7
[3]   Cytotoxicity of Zr-based bulk metallic glasses [J].
Buzzi, S ;
Jin, KF ;
Uggowitzer, PJ ;
Tosatti, S ;
Gerber, T ;
Löffler, JF .
INTERMETALLICS, 2006, 14 (07) :729-734
[4]   Phenotypic non-equivalence of murine (monocyte-) macrophage cells in biomaterial and inflammatory models [J].
Chamberlain, Lisa M. ;
Godek, Marisha L. ;
Gonzalez-Juarrero, Mercedes ;
Grainger, David W. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 88A (04) :858-871
[5]   Characterization of topographical effects on macrophage behavior in a foreign body response model [J].
Chen, Sulin ;
Jones, Jacqueline A. ;
Xu, Yongan ;
Low, Hong-Yee ;
Anderson, James M. ;
Leong, Kam W. .
BIOMATERIALS, 2010, 31 (13) :3479-3491
[6]   Effect of surface roughness of the titanium alloy Ti-6Al-4V on human bone marrow cell response and on protein adsorption [J].
Deligianni, DD ;
Katsala, N ;
Ladas, S ;
Sotiropoulou, D ;
Amedee, J ;
Missirlis, YF .
BIOMATERIALS, 2001, 22 (11) :1241-1251
[7]   Amorphous Metals for Hard-tissue Prosthesis [J].
Demetriou, Marios D. ;
Wiest, Aaron ;
Hofmann, Douglas C. ;
Johnson, William L. ;
Han, Bo ;
Wolfson, Nikolaj ;
Wang, Gongyao ;
Liaw, Peter K. .
JOM, 2010, 62 (02) :83-91
[8]   Immune responses to implants - A review of the implications for the design of immunomodulatory biomaterials [J].
Franz, Sandra ;
Rammelt, Stefan ;
Scharnweber, Dieter ;
Simon, Jan C. .
BIOMATERIALS, 2011, 32 (28) :6692-6709
[9]   Ti based biomaterials, the ultimate choice for orthopaedic implants - A review [J].
Geetha, M. ;
Singh, A. K. ;
Asokamani, R. ;
Gogia, A. K. .
PROGRESS IN MATERIALS SCIENCE, 2009, 54 (03) :397-425
[10]   Biocompatibility Study of Zirconium-Based Bulk Metallic Glasses for Orthopedic Applications [J].
He, Wei ;
Chuang, Andrew ;
Cao, Zheng ;
Liaw, Peter K. .
METALLURGICAL AND MATERIALS TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 2010, 41A (07) :1726-1734