Measuring Diffusion of Lipid-like Probes in Artificial and Natural Membranes by Raster Image Correlation Spectroscopy (RICS): Use of a Commercial Laser-Scanning Microscope with Analog Detection

被引:51
作者
Gielen, Ellen [1 ,2 ,3 ]
Smisdom, Nick [1 ,2 ]
vandeVen, Martin [1 ,2 ]
De Clercq, Ben [1 ,2 ]
Gratton, Enrico [4 ]
Digman, Michelle [4 ]
Rigo, Jean-Michel [1 ,2 ]
Hofkens, Johan [5 ]
Engelborghs, Yves [3 ]
Ameloot, Marcel [1 ,2 ]
机构
[1] Hasselt Univ, Biomed Res Inst, Lab Cell Physiol, B-3590 Diepenbeek, Belgium
[2] Transnatl Univ Limburg, B-3590 Diepenbeek, Belgium
[3] Katholieke Univ Leuven, Lab Biomol Dynam, B-3001 Heverlee, Belgium
[4] Univ Calif Irvine, Dept Biomed Engn, Fluorescence Dynam Lab, Irvine, CA 92697 USA
[5] Katholieke Univ Leuven, Lab Photochem & Spect, B-3001 Heverlee, Belgium
关键词
FLUORESCENCE CORRELATION SPECTROSCOPY; CROSS-CORRELATION SPECTROSCOPY; PLASMA-MEMBRANE; CELL; DYNAMICS; LAWS; OLIGODENDROCYTE; CONFINEMENT; MYELIN; RAFTS;
D O I
10.1021/la8040538
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The heterogeneity in composition and interaction within the cellular membrane translates into a wide range of diffusion coefficients of its constituents. Therefore, several complementary microfluorimetric techniques such as fluorescence correlation spectroscopy (FCS), fluorescence recovery after photobleaching (FRAP) and single-particle tracking (SPT) have to be applied to explore the dynamics of membrane components. The recently introduced raster image correlation spectroscopy (RICS) offers a much wider dynamic range than each of these methods separately and allows for spatial mapping of the dynamic properties. RICS is implemented on a confocal laser-scanning microscope (CLSM), and the wide dynamic range is achieved by exploiting the inherent time information carried by the scanning laser beam in the generation of the confocal images. The original introduction of RICS used two-photon excitation and photon counting detection. However, most CLSM systems are based on one-photon excitation with analog detection. Here we report on the performance of such a commercial CLSM (Zeiss LSM 510 META) in the study of the diffusion of the fluorescent lipid analog 1,1'-dioctadecyl-3,3,3',3'-tetramethyl-indodicarbocyanine perchlorate (Dil-C-18(5)) both in giant unilamellar vesicles and in the plasma membrane of living oligodendrocytes, i.e., the myelin-producing cells of the central nervous system. It is shown that RICS on a commercial CLSM with analog detection allows for reliable results in the study of membrane diffusion by removal of unwanted correlations introduced by the analog detection system. The results obtained compare well with those collected by FRAP and FCS.
引用
收藏
页码:5209 / 5218
页数:10
相关论文
共 37 条
[1]  
ANGELOVA MI, 1992, PROG COLL POL SCI S, V89, P127
[2]   LIPOSOME ELECTROFORMATION [J].
ANGELOVA, MI ;
DIMITROV, DS .
FARADAY DISCUSSIONS, 1986, 81 :303-+
[3]   A dynamic view of cellular processes by in vivo fluorescence auto- and cross-correlation spectroscopy [J].
Bacia, K ;
Schwille, P .
METHODS, 2003, 29 (01) :74-85
[4]   Fluorescence correlation spectroscopy relates rafts in model and native membranes [J].
Bacia, K ;
Scherfeld, D ;
Kahya, N ;
Schwille, P .
BIOPHYSICAL JOURNAL, 2004, 87 (02) :1034-1043
[5]   Biology of oligodendrocyte and myelin in the mammalian central nervous system [J].
Baumann, N ;
Pham-Dinh, D .
PHYSIOLOGICAL REVIEWS, 2001, 81 (02) :871-927
[6]   Line FRAP with the confocal laser scanning microscope for diffusion measurements in small regions of 3-D samples [J].
Braeckmans, Kevin ;
Remaut, Katrien ;
Vandenbroucke, Roosmarijn E. ;
Lucas, Bart ;
De Smedt, Stefaan C. ;
Demeester, Joseph .
BIOPHYSICAL JOURNAL, 2007, 92 (06) :2172-2183
[7]   Raster image correlation spectroscopy (RICS) for measuring fast protein dynamics and concentrations with a commercial laser scanning confocal microscope [J].
Brown, C. M. ;
Dalal, R. B. ;
Hebert, B. ;
Digman, M. A. ;
Horwitz, A. R. ;
Gratton, E. .
JOURNAL OF MICROSCOPY-OXFORD, 2008, 229 (01) :78-91
[8]   Accuracy and dynamic range of spatial image correlation and cross-correlation spectroscopy [J].
Costantino, S ;
Comeau, JWD ;
Kolin, DL ;
Wiseman, PW .
BIOPHYSICAL JOURNAL, 2005, 89 (02) :1251-1260
[9]   Relationship of lipid rafts to transient confinement zones detected by single particle tracking [J].
Dietrich, C ;
Yang, B ;
Fujiwara, T ;
Kusumi, A ;
Jacobson, K .
BIOPHYSICAL JOURNAL, 2002, 82 (01) :274-284
[10]   Fluctuation correlation spectroscopy with a laser-scanning microscope: Exploiting the hidden time structure [J].
Digman, MA ;
Sengupta, P ;
Wiseman, PW ;
Brown, CM ;
Horwitz, AR ;
Gratton, E .
BIOPHYSICAL JOURNAL, 2005, 88 (05) :L33-L36