Non-invasive glucose measuring apparatus based on conservation of energy method

被引:6
作者
Chen Zhen-cheng [1 ]
Jin Xing-liang [1 ]
Zhu Jian-ming [1 ]
Wang Di-ya [1 ]
Zhang Ting-ting [1 ]
机构
[1] Cent S Univ, Sch Infophys & Geomat Engn, Changsha 410083, Peoples R China
来源
JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY | 2009年 / 16卷 / 06期
关键词
single chip; non-invasive measurement; blood glucose; conservation of energy method; GINGIVAL CREVICULAR FLUID; BLOOD;
D O I
10.1007/s11771-009-0163-7
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
A new non-invasive blood glucose measuring apparatus (NBGMA) made up of MSP430F149 SCM (single chip micyoco) was developed, which can measure blood glucose level (BGL) frequently, conveniently and painlessly. The hardware and software of this apparatus were designed, and detecting algorithms based on conservation of energy method (COEM) were presented. According to the law of conservation of energy that the energy derived by human body equals energy consumed by metabolism, and the relationship between convection, evaporation, radiation and the BGL was established. The sensor module was designed. 20 healthy volunteers were involved in the clinical experiment. The BGL measured by an automatic biochemical analyzer (ABA) was set as the reference. Regression analysis was performed to compare the conservation of energy method with the biochemical method, using the 20 data points with blood glucose concentrations ranging from 680 to 1 100 mg/L. Reproducibility was measured for healthy fasting volunteers. The results show that the means of BGL detected by NBGMA and ANA are very close to each other, and the difference of standard deviation (SD) is 24.7 mg/L. The correlative coefficient is 0.807. The coefficient of variation (CV) is 4% at 921.6 mg/L. The resultant regression is evaluated by the Clarke error grid analysis (EGA) and all data points are included in the clinically acceptable regions (region A: 100%, region B: 0%). Accordingly, it is feasible to measure BGL with COEM.
引用
收藏
页码:982 / 986
页数:5
相关论文
共 16 条
  • [1] First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system
    Caduff, A
    Hirt, E
    Feldman, Y
    Ali, Z
    Heinemann, L
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 19 (03) : 209 - 217
  • [2] Chen Wenliang, 2004, Sheng Wu Yi Xue Gong Cheng Xue Za Zhi, V21, P824
  • [3] Chen ZC, 2007, CHINESE J ANAL CHEM, V35, P615
  • [4] Chen Zhen-cheng, 2008, Chinese Journal of Sensors and Actuators, V21, P1119
  • [5] Chen Zhen-cheng, 2008, Chinese Journal of Sensors and Actuators, V21, P724
  • [6] A novel disposable amperometric UA strip
    Chen, Zhencheng
    Fang, Cheng
    Wang, Hongyan
    He, Jishan
    Deng, Zhencheng
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2008, 129 (02) : 710 - 715
  • [7] CHO OK, 2004, Patent No. 20040225209
  • [8] Kuwa Katsuhiko, 2006, Rinsho Byori, V54, P519
  • [9] Sieg Anke, 2005, Diabetes Technol Ther, V7, P174, DOI 10.1089/dia.2005.7.174
  • [10] Sun Fei, 2005, Sheng Wu Yi Xue Gong Cheng Xue Za Zhi, V22, P171