Accuracy and usefulness of fusion imaging between three-dimensional coronary sinus and coronary veins computed tomographic images with projection images obtained using fluoroscopy

被引:20
|
作者
Auricchio, Angelo [1 ]
Sorgente, Antonio [1 ]
Soubelet, Elisabeth [2 ]
Regoli, Francois [1 ]
Spinucci, Giulio [1 ,3 ]
Vaillant, Regis [2 ]
Faletra, Francesco F. [1 ]
Klersy, Catherine [4 ]
Moccetti, Tiziano [1 ]
机构
[1] Fdn Cardioctr Ticino, Div Cardiol, Lugano, Switzerland
[2] GE Healthcare, Buc, France
[3] Univ Perugia, Sch Med, Div Cardiol, I-06100 Perugia, Italy
[4] Policlin San Matteo, Fdn IRCCS, Biometry & Clin Epidemiol Serv, Res Dept, I-27100 Pavia, Italy
来源
EUROPACE | 2009年 / 11卷 / 11期
关键词
Coronary sinus anatomy; Computed tomography imaging; Cardiac resynchronization therapy; Heart failure; Device therapy; CARDIAC RESYNCHRONIZATION THERAPY; LEFT-VENTRICULAR LEAD; ATRIAL-FIBRILLATION; VENOUS SYSTEM; CATHETER ABLATION; RADIOFREQUENCY ABLATION; HEART-FAILURE; VISUALIZATION; REGISTRATION; ANGIOGRAPHY;
D O I
10.1093/europace/eup237
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Coronary sinus (CS) and coronary veins are not delineated by fluoroscopy. The study evaluates the feasibility and accuracy of cardiac tomography (CT) image registration of CS anatomy on fluoroscopic image. Eighteen consecutive patients underwent contrast-enhanced, ECG-gated CT scanning. Coronary sinus, coronary veins, superior vena cava, the distal portion of the trachea, and of the two main bronchi were reconstructed. These images were then fused over the CS fluoroscopic angiogram. Registration accuracy was verified by assessing the overlap of CS borders both in the CT- and in the fluoroscopy-derived images. The mean distance between the centrelines of the CS was 0.73 mm, with a maximum distance of 2.22 mm. For the first-order branches, mean distance was 0.80 mm with a maximum distance of 2.64 mm. High Lin concordance correlation coefficients were computed (> 0.95) for the CS and first-order branch diameters, although the Bland and Altman limits were large. The agreement between the number of vessels identified was moderate with kappa = 0.43. Fusion imaging processing of two different imaging modalities (CT and fluoroscopy) may be feasible and accurate for guiding CRT implantation as it allows constant comprehensive display of CS body and branches. Prospective studies are needed for assessing clinical implications.
引用
收藏
页码:1483 / 1490
页数:8
相关论文
共 50 条
  • [21] A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images
    Oh, Suseok
    Kim, Ci-Young
    Hong, Jongrak
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2014, 40 (03) : 123 - 129
  • [22] Three-dimensional fusion of morphological data obtained by coronary computed tomography angiography with quantitative echocardiographic data on regional myocardial function
    Lipiec, P.
    Wejner-Mik, P.
    Wdowiak-Okrojek, K.
    Szymczyk, E.
    Skurski, A.
    Napieralski, A.
    Kaminski, M.
    Szymczyk, K.
    Kasprzak, J. D.
    EUROPEAN HEART JOURNAL, 2014, 35 : 520 - 520
  • [23] Usefulness of three-dimensional visualization of coronary arteries using electron-beam computed tomography data with volume rendering
    Funabashi, N
    Matsumoto, A
    Yoshida, T
    Watanabe, S
    Misumi, K
    Masuda, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2000, 64 (08): : 644 - 646
  • [24] A detailed comparison between the endoscopic images using blue laser imaging and three-dimensional reconstructed pathological images of colonic lesions
    Ueda, Takeshi
    Morita, Kohei
    Koyama, Fumikazu
    Teramura, Yuichi
    Nakagawa, Tadashi
    Nakamura, Shinji
    Matsumoto, Yayoi
    Inoue, Takashi
    Nakamoto, Takayuki
    Sasaki, Yoshiyuki
    Kuge, Hiroyuki
    Takeda, Maiko
    Ohbayashi, Chiho
    Fujii, Hisao
    Sho, Masayuki
    PLOS ONE, 2020, 15 (06):
  • [25] Time-resolved three-dimensional imaging of the left atrium and pulmonary veins in the interventional suite -: A comparison between muttisweep gated rotational three-dimensional reconstructed fluoroscopy and multislice computed tomography
    Al-Ahmad, Amin
    Wigstroem, Lars
    Sandner-Porkristl, Dominique
    Wang, Paul J.
    Zei, Paul C.
    Boese, Jan
    Lauritsch, Guenter
    Moore, Teri
    Chan, Frandics
    Fahrig, Rebecca
    HEART RHYTHM, 2008, 5 (04) : 513 - 519
  • [26] Quantitative assessment of diffuse coronary artery disease using a three-dimensional reconstruction method compared with intravascular ultrasound images
    Tsuchiya, T
    Shimizu, M
    Yoshio, H
    Ino, H
    Okeie, K
    Yasuda, T
    Mabuchi, H
    CORONARY ARTERY DISEASE, 2001, 12 (02) : 127 - 133
  • [27] Quantitative assessment of diffuse coronary artery disease using a three-dimensional reconstruction method compared with intravascular ultrasound images
    Gould, KL
    CORONARY ARTERY DISEASE, 2002, 13 (03) : 199 - 199
  • [28] Three-dimensional reconstruction and NURBS-based structured meshing of coronary arteries from the conventional X-ray angiography projection images
    Arso M. Vukicevic
    Serkan Çimen
    Nikola Jagic
    Gordana Jovicic
    Alejandro F. Frangi
    Nenad Filipovic
    Scientific Reports, 8
  • [29] Three-dimensional reconstruction and NURBS-based structured meshing of coronary arteries from the conventional X-ray angiography projection images
    Vukicevic, Arso M.
    Cimen, Serkan
    Jagic, Nikola
    Jovicic, Gordana
    Frangi, Alejandro F.
    Filipovic, Nenad
    SCIENTIFIC REPORTS, 2018, 8
  • [30] Rapid Three-Dimensional Reconstruction of Underwater Defective Pile Based on Two-Dimensional Images Obtained Using Mechanically Scanned Imaging Sonar
    Shen, Sheng
    Zeng, Yamian
    Lai, Changqin
    Jiang, Shaofei
    Wu, Shaofen
    Ma, Shenglan
    STRUCTURAL CONTROL & HEALTH MONITORING, 2023, 2023