Semiautomated digital analysis of knee joint space width using MR images

被引:3
作者
Agnesi, Filippo
Amrami, Kimberly K.
Frigo, Carlo A.
Kaufman, Kenton R.
机构
[1] Mayo Clin & Mayo Fdn, Dept Orthoped Surg, Mot Anal Lab, Div Orthoped Res, Rochester, MN 55905 USA
[2] Politecn Milan, Dept Bioengn, I-20133 Milan, Italy
[3] Mayo Clin, Dept Radiol, Rochester, MN USA
关键词
joint space width; digital analysis; osteoarthritis; MRI;
D O I
10.1007/s00256-006-0245-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective The goal of this study was to ( a) develop a semiautomated computer algorithm to measure knee joint space width ( JSW) from magnetic resonance (MR) images using standard imaging techniques and (b) evaluate the reproducibility of the algorithm. Design Using a standard clinical imaging protocol, bilateral knee MR images were obtained twice within a 2-week period from 17 asymptomatic research participants. Images were analyzed to determine the variability of the measurements performed by the program compared with the variability of manual measurements. Results Measurement variability of the computer algorithm was considerably smaller than the variability of manual measurements. The average difference between two measurements of the same slice performed with the computer algorithm by the same user was 0.004 +/- 0.07 mm for the tibiofemoral joint (TF) and 0.009 +/- 0.11 mm for the patellofemoral joint (PF) compared with an average of 0.12 +/- 0.22 mm TF and 0.13 +/- 0.29 mm PF, respectively, for the manual method. Interuser variability of the computer algorithm was also considerably smaller, with an average difference of 0.004 +/- 0.1 mm TF and 0.0006 +/- 0.1 mm PF compared with 0.38 +/- 0.59 mm TF and 0.31 +/- 0.66 mm PF obtained using a manual method. The between-day reproducibility was larger but still within acceptable limits at 0.09 +/- 0.39 mm TF and 0.09 +/- 0.51 mm PF. This technique has proven consistently reproducible on a same slice base, while the reproducibility comparing different acquisitions of the same subject was larger. Longitudinal reproducibility improvement needs to be addressed through acquisition protocol improvements. Conclusion A semiautomated method for measuring knee JSW from MR images has been successfully developed.
引用
收藏
页码:437 / 444
页数:8
相关论文
共 24 条
  • [1] Increased knee joint loads during walking are present in subjects with knee osteoarthritis
    Baliunas, AJ
    Hurwitz, DE
    Ryals, AB
    Karrar, A
    Case, JP
    Block, JA
    Andriacchi, TP
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2002, 10 (07) : 573 - 579
  • [2] BENNET GA, 1942, CHANGES JOINT VARIOU
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Boegård T, 1998, ACTA RADIOL, V39, P24
  • [5] BRUYERE O, 2006, OSTEOARTHR CARTIL
  • [6] Thrust during ambulation and the progression of knee osteoarthritis
    Chang, A
    Hayes, K
    Dunlop, D
    Hurwitz, D
    Song, J
    Cahue, S
    Genge, R
    Sharma, L
    [J]. ARTHRITIS AND RHEUMATISM, 2004, 50 (12): : 3897 - 3903
  • [7] DACRE JE, 1989, BRIT J RHEUMATOL, V28, P506
  • [8] In vivo reproducibility of three-dimensional cartilage volume and thickness measurements with MR imaging
    Eckstein, F
    Westhoff, J
    Sittek, H
    Maag, KP
    Haubner, M
    Faber, S
    Englmeier, KH
    Reiser, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (03) : 593 - 597
  • [9] No loss of cartilage volume over three years in patients with knee osteoarthritis as assessed by magnetic resonance imaging
    Gandy, SJ
    Dieppe, PA
    Keen, MC
    Maciewicz, RA
    Watt, I
    Waterton, JC
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2002, 10 (12) : 929 - 937
  • [10] Semi-automated digital image analysis of patellofemoral joint space width from lateral knee radiographs
    Grochowski, SK
    Amrami, KK
    Kaufman, K
    [J]. SKELETAL RADIOLOGY, 2005, 34 (10) : 644 - 648