MRI exploration for the evaluation of orbital implant biocolonization in children enucleated for retinoblastoma

被引:3
作者
Douira-Khomsi, W. [1 ]
Korchane, N. [2 ]
Louati, H. [1 ]
Bhouri, L. [2 ]
Kchaou, I. [1 ]
Ben Hassine, L. [1 ]
Bouguila, H. [2 ]
Ayed, S. [2 ]
Bellagha, I. [1 ]
机构
[1] Hop Enfants Tunis, Serv Radiol Pediat, Tunis 1007, Tunisia
[2] Inst Hedi Rais, Serv Ophtalmol A, Tunis, Tunisia
来源
JOURNAL FRANCAIS D OPHTALMOLOGIE | 2009年 / 32卷 / 08期
关键词
Orbital implant; Magnetic resonance imaging; Fibrovascular colonization; RESONANCE-IMAGING ASSESSMENT; FIBROVASCULAR INGROWTH;
D O I
10.1016/j.jfo.2009.06.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. - To evaluate the contribution of MRI exploration for the evaluation of orbital prothesis biocolonization. Patients and methods. - We studied ten eyes of ten children who underwent enucleation for retinoblastoma and synthetic hydroxyapatite orbital implantation. Each patient was examined by MRI imaging with gadolinium within 2 months to 1 year. Results. - After gadolinium administration, five implants showed an enhancement. Nodular enhancement around the implant was noted in one patient with a recurrence of retinoblastoma, and brain metastases were shown in two cases. None of the orbital implants was rejected. Conclusion. - Fibrovascular colonization reduces the risk of orbital implant migration. Magnetic resonance imaging is safe and effective in detecting extrusion or tolerance of the orbital implant. (C) 2009 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:540 / 543
页数:4
相关论文
共 9 条
[1]  
ATLAS SW, 1988, AM J NEURORADIOL, V9, P969
[2]   Magnetic resonance imaging assessment of fibrovascular ingrowth into porous polyethylene orbital implants [J].
Choi, Hee Young ;
Lee, Jong Soo ;
Park, Hyun Jun ;
Oum, Boo Sup ;
Kim, Hak Jin ;
Park, Do Youn .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (04) :354-359
[3]   Postcontrast magnetic resonance imaging assessment of porous polyethylene orbital implant (Medpor) [J].
De Potter, P ;
Duprez, T ;
Cosnard, G .
OPHTHALMOLOGY, 2000, 107 (09) :1656-1660
[4]  
DEPOTTER P, 1992, OPHTHALMOLOGY, V99, P824
[5]  
Flanders AE, 1996, NEURORADIOLOGY, V38, P273
[6]   EVALUATION OF VASCULARIZATION OF CORALLINE HYDROXYAPATITE OCULAR IMPLANTS BY MAGNETIC-RESONANCE-IMAGING [J].
HAMILTON, HE ;
CHRISTIANSON, MD ;
WILLIAMS, JP ;
THOMAS, RA .
CLINICAL IMAGING, 1992, 16 (04) :243-246
[7]   Magnetic resonance evaluation of fibrovascular ingrowth into porous polyethylene orbital implant [J].
Park, SW ;
Seol, HY ;
Hong, SJ ;
Kim, KA ;
Choi, JC ;
Cha, IH .
CLINICAL IMAGING, 2003, 27 (06) :377-381
[8]   GADOLINIUM-ENHANCED MAGNETIC-RESONANCE-IMAGING ASSESSMENT OF HYDROXYAPATITE ORBITAL IMPLANTS [J].
SPIRNAK, JP ;
NIEVES, N ;
HOLLSTEN, DA ;
WHITE, WC ;
BETZ, TA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1995, 119 (04) :431-440
[9]  
Van Acker E, 2001, J FR OPHTALMOL, V24, P1067