An Enhanced Strategy to Inhibit Commutation Failure in Line-Commutated Converters

被引:62
|
作者
Mirsaeidi, Sohrab [1 ]
Dong, Xinzhou [1 ]
机构
[1] Tsinghua Univ, Dept Elect Engn, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
AC faults; commutation failure; high-voltage direct current (HVdc) transmission; line-commutated converters (LCCs); LCC HVDC SYSTEM;
D O I
10.1109/TIE.2019.2896328
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Failure of the commutation process is a serious malfunction in line-commutated high-voltage direct current (HVdc) converters, which mainly occurs due to inverter ac faults and may lead to outage of the HVdc system. In this paper, an improved strategy is developed that functions based on the SIEMENS HVdc control system under normal conditions and switches to a designed commutation failure inhibition module (CFIM) during an inverter ac fault. From the response speed point of view, since the designed CFIM does not require any proportional-integral controller, the inverter control system has a quick performance in prevention of the commutation failure. This is achieved by direct measurement of the overlap area using the waveforms of the valves anode-cathode and commuting voltages. In addition, from the accuracy aspect, the proposed method has a superior performance in comparison with the existing strategies. It is because of the fact that by direct measurement of the overlap area, variations of both direct current and the commutation inductance are considered, and hence, the unnecessary increase of the inverter reactive power consumption during the fault and the repetitive commutation failures are prevented. The practical performance and feasibility of the proposed strategy is validated through the laboratory testing, using the real-time Opal-RT hardware prototyping platform. The experimental results demonstrate that the proposed strategy can effectively inhibit the commutation failure or repetitive commutation failures under different fault types by considering the lowest possible reactive power consumption.
引用
收藏
页码:340 / 349
页数:10
相关论文
共 50 条
  • [21] Extension of the Operational Range of High Performance Line-Commutated Converters into Discontinuous Current Mode
    Maestri, Sebastian
    Petrocelli, Roberto
    Uicich, Gustavo
    Benedetti, Mario
    Garcia Retegui, Rogelio
    EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9, 2009, : 2462 - +
  • [22] TRANSFER-FUNCTION MODEL OF FEEDBACK-CONTROL SYSTEM WITH LINE-COMMUTATED CONVERTERS
    KOSEKI, S
    MASADA, E
    ELECTRICAL ENGINEERING IN JAPAN, 1975, 95 (03) : 99 - 106
  • [23] An Improved Prevention Strategy Based on Fault Probability Detection for Commutation Failure in Line-Commutated Converter-Based High-Voltage Direct Current Transmission Systems
    Xu, Ying
    Zou, Yi
    Liu, Lei
    Li, Xiaopeng
    Teng, Yufei
    Gao, Zijian
    ELECTRONICS, 2024, 13 (19)
  • [24] A Review of Hybrid Topologies Combining Line-Commutated and Cascaded Full-Bridge Converters
    Bakas, Panagiotis
    Harnefors, Lennart
    Norrga, Staffan
    Nami, Alireza
    Ilves, Kalle
    Dijkhuizen, Frans
    Nee, Hans-Peter
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (10) : 7435 - 7448
  • [25] Convexification of Hybrid AC-DC Optimal Power Flow with Line-Commutated Converters
    Liang, Hongyuan
    Li, Zhigang
    Zheng, J. H.
    Wu, Q. H.
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2024, 10 (02): : 617 - 628
  • [26] Control and protection of series hybrid DC converters with a line-commutated converter and a voltage source converter
    Lu D.
    Tian J.
    Li H.
    Chen S.
    Cao D.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (15): : 92 - 101
  • [27] SITOR TRIGGER SETS FOR LINE-COMMUTATED RECTIFIERS
    LINDEN, W
    SCHAFER, HD
    THUMM, H
    SIEMENS ZEITSCHRIFT, 1977, 51 (04): : 315 - 318
  • [28] A new approach for the computation of harmonics and interharmonics produced by line-commutated AC/DC/AC converters
    Carbone, R
    De Rosa, F
    Langella, R
    Testa, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) : 2227 - 2234
  • [29] STEADY-STATE MATHEMATICAL-MODELS OF BATTERY STORAGE PLANTS WITH LINE-COMMUTATED CONVERTERS
    CARPINELLI, G
    GAGLIARDI, F
    RUSSO, M
    STURCHIO, A
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (02) : 494 - 503
  • [30] Commutation failure of capacitor commutated inverter
    Electric Power Department, Southeast University, Nanjing 210096, China
    Dianli Zidonghua Shebei Electr. Power Autom. Equip., 2007, 10 (56-58+63):