An assessment of intraocular pressure during fractionated peribulbar anaesthesia

被引:12
作者
Joshi, N [1 ]
Reynolds, A [1 ]
Porter, EJB [1 ]
Rubin, AP [1 ]
Kinnear, PE [1 ]
机构
[1] CHARING CROSS HOSP,DEPT ANAESTHET,LONDON W6 8RF,ENGLAND
关键词
D O I
10.1038/eye.1996.131
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This study of 20 patients undergoing elective cataract surgery was performed to investigate the change in intraocular pressure that accompanies extraconal peribulbar anaesthesia. We have demonstrated that each injection during peribulbar anaesthesia causes a small rise in intraocular pressure. The routine use of conventional external ocular compression overcomes this pressure rise and safely provides a satisfactory and progressive reduction in intraocular pressure prior to surgery. Our findings suggest that the volumes of anaesthetic solutions used in fractional peribulbar anaesthesia, if used in conjunction with external compression devices, result in intraocular pressures acceptable for intraocular surgery.
引用
收藏
页码:565 / 568
页数:4
相关论文
共 9 条
[1]   THE KEELER PULSAIR AIR IMPULSE TONOMETER - COMPARISON WITH THE PERKINS HAND-HELD APPLANATION TONOMETER FOR PERI-OPERATIVE MEASUREMENT OF INTRAOCULAR-PRESSURE [J].
BRICKER, SRW ;
MCGALLIARD, JN ;
MOSTAFA, SM .
ANAESTHESIA, 1990, 45 (01) :36-39
[2]   EXTRAOCULAR COMPRESSION PRIOR TO CATARACT-SURGERY - TIME-COURSE OF REDUCTION AND SUBSEQUENT RECOVERY OF INTRAOCULAR-PRESSURE [J].
CONSTABLE, PH ;
PORTER, EJB .
EYE, 1993, 7 :731-734
[3]   REGIONAL ANESTHESIA FOR 12,000 CATARACT-EXTRACTION AND INTRAOCULAR-LENS IMPLANTATION PROCEDURES [J].
HAMILTON, RC ;
GIMBEL, HV ;
STRUNIN, L .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1988, 35 (06) :615-623
[4]   INTRAOCULAR-PRESSURE AFTER PERIBULBAR ANESTHESIA - IS THE HONAN BALLOON NECESSARY [J].
MORGAN, JE ;
CHANDNA, A .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1995, 79 (01) :46-49
[5]   PERIBULBAR VERSUS RETROBULBAR ANESTHESIA [J].
MURDOCH, IE .
EYE, 1990, 4 :445-449
[6]  
NIELSEN L, 1990, Ugeskrift for Laeger, V152, P329
[7]   EFFECT ON INTRAOCULAR-PRESSURE OF LOCAL-ANESTHESIA IN EYES UNDERGOING INTRAOCULAR SURGERY [J].
ODONOGHUE, E ;
BATTERBURY, M ;
LAVY, T .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1994, 78 (08) :605-607
[8]  
PALAY DA, 1990, OPHTHALMIC SURG LAS, V21, P503
[9]   REPRODUCIBILITY WITH THE KEELER PULSAIR-2000 NONCONTACT TONOMETER [J].
VERNON, SA .