Percutaneous pulmonary valve implantation with the Venus P-valve: clinical experience and early results

被引:66
作者
Promphan, Worakan [1 ]
Prachasilchai, Pimpak [1 ]
Siripornpitak, Suvipaporn [3 ]
Qureshi, Shakeel A. [2 ]
Layangool, Thanarat [1 ]
机构
[1] Rangsit Univ, Coll Med, Queen Sirikit Natl Inst Child Hlth, Pediat Heart Ctr, Bangkok, Thailand
[2] Mahidol Univ, Ramathibodi Hosp, Fac Med, Dept Radiol, Bangkok 10400, Thailand
[3] Guys & St Thomas NHS Fdn Trust, Evelina London Childrens Hosp, Dept Paediat Cardiol, London, England
关键词
Pulmonary regurgitation; percutaneous pulmonary valve implantation; Venus P-valve (TM); REPLACEMENT; TETRALOGY; DYSFUNCTION; PRESSURE; DEVICE;
D O I
10.1017/S1047951115001067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background At present, the exclusion for percutaneous pulmonary valve implantation for free pulmonary regurgitation after tetralogy of Fallot repair includes an unfavourably large right ventricular outflow tract. Objective To report feasibility and early experience with a recently developed transcatheter heart valve, Venus P-valve(TM), implanted in six patients with severe pulmonary regurgitation with large right ventricular outflow tracts. Patients There were two female patients and four male patients. The median age of the patients was 18.5 years, and the mean body weight was 53.8 kg. All the patients were in NYHA class II and had severe pulmonary regurgitation after previous transannular patch repair of tetralogy of Fallot. The median time after the last surgical operation was 13.5 years. Results The Venus P-valve(TM) was successfully implanted in all the patients with implanted valve diameters ranging from 24 to 32 mm. The mean fluoroscopy time was 29.8 minutes. None of the patients had significant outflow tract gradient or pulmonary regurgitation immediately after valve implantation. Only one patient had unexpected mild proximal valve migration to the right ventricular body during withdrawal of the delivery system. It caused mild paravalvar leak and significant tricuspid regurgitation. At 6 months follow-up, the median of right ventricular end-diastolic volume indices decreased from 146 to 108 ml/m(2) (p-value=0.046). The Doppler systolic peak gradient across the valve ranged from 4 to 40 mmHg, and there was no evidence of stent fracture on fluoroscopy or structural valve failure. Conclusion The Venus P-valve(TM) can be implanted successfully and effectively in patients with severe pulmonary regurgitation and a large right ventricular outflow tract. The early results with this valve are encouraging.
引用
收藏
页码:698 / 710
页数:13
相关论文
共 20 条
[11]   Physiological and Phenotypic Characteristics of Late Survivors of Tetralogy of Fallot Repair Who Are Free From Pulmonary Valve Replacement [J].
Frigiola, Alessandra ;
Hughes, Marina ;
Turner, Mark ;
Taylor, Andrew ;
Marek, Jan ;
Giardini, Alessandro ;
Hsia, Tain-Yen ;
Bull, Kate .
CIRCULATION, 2013, 128 (17) :1861-1868
[12]   Percutaneous implantation of the Edwards SAPIEN™ pulmonic valve: initial results in the first 22 patients [J].
Haas, Nikolaus A. ;
Moysich, Axel ;
Neudorf, Ulrich ;
Mortezaeian, Hojjat ;
Abdel-Wahab, Mohamed ;
Schneider, Heike ;
De Wolf, Daniel ;
Petit, Jerome ;
Narayanswami, Sreeram ;
Laser, Kai Thorsten ;
Sandica, Eugen .
CLINICAL RESEARCH IN CARDIOLOGY, 2013, 102 (02) :119-128
[13]   Pulmonary Valve Replacement in Tetralogy of Fallot Impact on Survival and Ventricular Tachycardia [J].
Harrild, David M. ;
Berul, Charles I. ;
Cecchin, Frank ;
Geva, Tal ;
Gauvreau, Kimberlee ;
Pigula, Frank ;
Walsh, Edward P. .
CIRCULATION, 2009, 119 (03) :445-451
[14]   Short-Term Performance of the Transcatheter Melody Valve in High-Pressure Hemodynamic Environments in the Pulmonary and Systemic Circulations [J].
Hasan, Babar S. ;
McElhinney, Doff B. ;
Brown, David W. ;
Cheatham, John P. ;
Vincent, Julie A. ;
Hellenbrand, William E. ;
Jones, Thomas K. ;
Zahn, Evan M. ;
Lock, James E. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (06) :615-620
[15]   Reliability of intraoperative transesophageal echocardiography during tetralogy of fallot repair [J].
Joyce, JJ ;
Hwang, EY ;
Wiles, HB ;
Kline, CH ;
Bradley, SM ;
Crawford, FA .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2000, 17 (04) :319-327
[16]   Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve for Conduit Failure in the Pulmonary Position Early Phase 1 Results From an International Multicenter Clinical Trial [J].
Kenny, Damien ;
Hijazi, Ziyad M. ;
Kar, Saibal ;
Rhodes, John ;
Mullen, Michael ;
Makkar, Raj ;
Shirali, Girish ;
Fogel, Mark ;
Fahey, John ;
Heitschmidt, Mary G. ;
Cain, Christopher .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (21) :2248-2256
[17]   Stent Fracture, Valve Dysfunction, and Right Ventricular Outflow Tract Reintervention After Transcatheter Pulmonary Valve Implantation Patient-Related and Procedural Risk Factors in the US Melody Valve Trial [J].
McElhinney, Doff B. ;
Cheatham, John P. ;
Jones, Thomas K. ;
Lock, James E. ;
Vincent, Julie A. ;
Zahn, Evan M. ;
Hellenbrand, William E. .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (06) :602-U130
[18]   Risk stratification, systematic classification, and anticipatory management strategies for stent fracture after percutaneous pulmonary valve implantation [J].
Nordmeyer, Johannes ;
Khambadkone, Sachin ;
Coats, Louise ;
Schievano, Silvia ;
Lurz, Philipp ;
Parenzan, Giovanni ;
Taylor, Andrew M. ;
Lock, James E. ;
Bonhoeffer, Philipp .
CIRCULATION, 2007, 115 (11) :1392-1397
[19]   First-in-man implantation of a novel percutaneous valve: a new approach to medical device development [J].
Schievano, Silvia ;
Taylor, Andrew M. ;
Capelli, Claudio ;
Coats, Louise ;
Walker, Fiona ;
Lurz, Philipp ;
Nordmeyer, Johannes ;
Wright, Sue ;
Khambadkone, Sachin ;
Tsang, Victor ;
Carminati, Mario ;
Bonhoeffer, Philipp .
EUROINTERVENTION, 2010, 5 (06) :745-750
[20]   NONINVASIVE ESTIMATION OF RIGHT VENTRICULAR SYSTOLIC PRESSURE BY DOPPLER ULTRASOUND IN PATIENTS WITH TRICUSPID REGURGITATION [J].
YOCK, PG ;
POPP, RL .
CIRCULATION, 1984, 70 (04) :657-662