Percutaneous pulmonary valve implantation with the Venus P-valve: clinical experience and early results

被引:66
作者
Promphan, Worakan [1 ]
Prachasilchai, Pimpak [1 ]
Siripornpitak, Suvipaporn [3 ]
Qureshi, Shakeel A. [2 ]
Layangool, Thanarat [1 ]
机构
[1] Rangsit Univ, Coll Med, Queen Sirikit Natl Inst Child Hlth, Pediat Heart Ctr, Bangkok, Thailand
[2] Mahidol Univ, Ramathibodi Hosp, Fac Med, Dept Radiol, Bangkok 10400, Thailand
[3] Guys & St Thomas NHS Fdn Trust, Evelina London Childrens Hosp, Dept Paediat Cardiol, London, England
关键词
Pulmonary regurgitation; percutaneous pulmonary valve implantation; Venus P-valve (TM); REPLACEMENT; TETRALOGY; DYSFUNCTION; PRESSURE; DEVICE;
D O I
10.1017/S1047951115001067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background At present, the exclusion for percutaneous pulmonary valve implantation for free pulmonary regurgitation after tetralogy of Fallot repair includes an unfavourably large right ventricular outflow tract. Objective To report feasibility and early experience with a recently developed transcatheter heart valve, Venus P-valve(TM), implanted in six patients with severe pulmonary regurgitation with large right ventricular outflow tracts. Patients There were two female patients and four male patients. The median age of the patients was 18.5 years, and the mean body weight was 53.8 kg. All the patients were in NYHA class II and had severe pulmonary regurgitation after previous transannular patch repair of tetralogy of Fallot. The median time after the last surgical operation was 13.5 years. Results The Venus P-valve(TM) was successfully implanted in all the patients with implanted valve diameters ranging from 24 to 32 mm. The mean fluoroscopy time was 29.8 minutes. None of the patients had significant outflow tract gradient or pulmonary regurgitation immediately after valve implantation. Only one patient had unexpected mild proximal valve migration to the right ventricular body during withdrawal of the delivery system. It caused mild paravalvar leak and significant tricuspid regurgitation. At 6 months follow-up, the median of right ventricular end-diastolic volume indices decreased from 146 to 108 ml/m(2) (p-value=0.046). The Doppler systolic peak gradient across the valve ranged from 4 to 40 mmHg, and there was no evidence of stent fracture on fluoroscopy or structural valve failure. Conclusion The Venus P-valve(TM) can be implanted successfully and effectively in patients with severe pulmonary regurgitation and a large right ventricular outflow tract. The early results with this valve are encouraging.
引用
收藏
页码:698 / 710
页数:13
相关论文
共 20 条
[1]   ESC Guidelines for the management of grown-up congenital heart disease (new version 2010) [J].
Baumgartner, Helmut ;
Bonhoeffer, Philipp ;
De Groot, Natasja M. S. ;
de Haan, Fokko ;
Deanfield, John Erik ;
Galie, Nazzareno ;
Gatzoulis, Michael A. ;
Gohlke-Baerwolf, Christa ;
Kaemmerer, Harald ;
Kilner, Philip ;
Meijboom, Folkert ;
Mulder, Barbara J. M. ;
Oechslin, Erwin ;
Oliver, Jose M. ;
Serraf, Alain ;
Szatmari, Andras ;
Thaulow, Erik ;
Vouhe, Pascal R. ;
Walma, Edmond .
EUROPEAN HEART JOURNAL, 2010, 31 (23) :2915-2957
[2]   Virtual and real bench testing of a new percutaneous valve device: a case study [J].
Biglino, Giovanni ;
Capelli, Claudio ;
Binazzi, Alia ;
Reggiani, Rita ;
Cosentino, Daria ;
Migliavacca, Francesco ;
Bonhoeffer, Philipp ;
Taylor, Andrew M. ;
Schievano, Silvia .
EUROINTERVENTION, 2012, 8 (01) :120-128
[3]   Percutaneous replacement of pulmonary valve in a right-ventricle to pulmonary-artery prosthetic conduit with valve dysfunction [J].
Bonhoeffer, P ;
Boudjemline, Y ;
Saliba, Z ;
Merckx, J ;
Aggoun, Y ;
Bonnet, D ;
Acar, P ;
Le Bidois, J ;
Sidi, D ;
Kachaner, J .
LANCET, 2000, 356 (9239) :1403-1405
[4]   Early Clinical Experience With a Novel Self-Expanding Percutaneous Stent-Valve in the Native Right Ventricular Outflow Tract [J].
Cao, Qi-Ling ;
Kenny, Damien ;
Zhou, Daxin ;
Pan, Wenzhi ;
Guan, Lihua ;
Ge, Junbo ;
Hijazi, Ziyad M. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (07) :1131-1137
[5]  
Cao QL, 2013, PCR1128J GAT MED INN
[6]   Right ventricular dysfunction and pulmonary valve replacement after correction of tetralogy of Fallot - Discussion [J].
Weiman, DS ;
Bennink, GBWE ;
Mavroudis, C .
ANNALS OF THORACIC SURGERY, 2002, 73 (06) :1800-1800
[7]   Percutaneous Pulmonary Valve Implantation Preceded by Routine Prestenting With a Bare Metal Stent [J].
Demkow, Marcin ;
Biernacka, Elzbieta Katarzyna ;
Spiewak, Mateusz ;
Kowalski, Miroslaw ;
Siudalska, Hanna ;
Wolski, Piotr ;
Sondergaard, Lars ;
Misko, Jolanta ;
Hoffman, Piotr ;
Ruzyllo, Witold .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2011, 77 (03) :381-389
[8]   Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients [J].
Eicken, Andreas ;
Ewert, Peter ;
Hager, Alfred ;
Peters, Bjoern ;
Fratz, Sohrab ;
Kuehne, Titus ;
Busch, Raymonde ;
Hess, John ;
Berger, Felix .
EUROPEAN HEART JOURNAL, 2011, 32 (10) :1260-1265
[9]   Indications for Cardiac Catheterization and Intervention in Pediatric Cardiac Disease A Scientific Statement From the American Heart Association [J].
Feltes, Timothy F. ;
Bacha, Emile ;
Beekman, Robert H., III ;
Cheatham, John P. ;
Feinstein, Jeffrey A. ;
Gomes, Antoinette S. ;
Hijazi, Ziyad M. ;
Ing, Frank F. ;
de Moor, Michael ;
Morrow, W. Robert ;
Mullins, Charles E. ;
Taubert, Kathryn A. ;
Zahn, Evan M. .
CIRCULATION, 2011, 123 (22) :2607-2652
[10]   Biventricular response after pulmonary valve replacement for right ventricular outflow tract dysfunction - Is age a predictor of outcome? [J].
Frigiola, Alessandra ;
Tsang, Victor ;
Bull, Catherine ;
Coats, Louise ;
Khambadkone, Sachin ;
Derrick, Graham ;
Mist, Bryan ;
Walker, Fiona ;
van Doorn, Carin ;
Bonhoeffer, Philipp ;
Taylor, Andrew M. .
CIRCULATION, 2008, 118 (14) :S182-S190