Effects of exercise and respiration on hemodynamic efficiency in CFD simulations of the total cavopulmonary connection

被引:144
作者
Marsden, Alison L. [1 ]
Vignon-Clementel, Irene E.
Chan, Frandics P.
Feinstein, Jeffrey A.
Taylor, Charles A.
机构
[1] Stanford Univ, Clark Ctr E350, Dept Pediat, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Mech Engn, Stanford, CA 94305 USA
[3] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
Fontan; TCPC; single ventricle; respiration; exercise; hypoplastic left heart; computational fluid dynamics;
D O I
10.1007/s10439-006-9224-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Congenital heart defects with a single functional ventricle, such as hypoplastic left heart syndrome and tricuspid atresia, require a staged surgical approach to separate the systemic and pulmonary circulations. Ultimately, the venous or pulmonary side of the heart is bypassed by directly connecting the vena cava to the pulmonary arteries with a modified t-shaped junction. The Fontan procedure (total cavopulmonary connection, TCPC) completes this process of separation. To date, computational fluid dynamics (CFD) simulations in this low pressure, passive flow, intrathoracic system have neglected the presumed important effects of respiration on physiology and higher "stress" states such as with exercise have never been considered. We hypothesize that incorporating effects of respiration and exercise would provide more realistic estimates of TCPC performance. Time-dependent, 3D blood flow simulations are performed by a custom finite element solver for two patient-specific Fontan models with a novel respiration model, developed to generate physiologic time-varying flow conditions. Blood flow features, pressure, and energy efficiency are analyzed at rest and with increasing flow rates to simulate exercise conditions. The simulations produce realistic pressure and flow data, comparable to that measured by catheterization and echocardiography, and demonstrate substantial increases in energy dissipation (i.e. decreased performance) with exercise and respiration due to increasing intensity of small scale vortices in the flow. As would be expected, these changes are highly dependent on patient-specific anatomy and Fontan geometry. We propose that respiration and exercise should be incorporated into TCPC CFD simulations to provide increasingly realistic evaluations of TCPC performance.
引用
收藏
页码:250 / 263
页数:14
相关论文
共 33 条
[1]  
Chen YF, 2003, NANO LETT, V3, P581, DOI [10.1021/nl034086g, 10.1021/n1034086g]
[2]   Blood flow conditions in the proximal pulmonary arteries and vena cavae: healthy children during upright cycling exercise [J].
Cheng, CP ;
Herfkens, RJ ;
Lightner, AL ;
Taylor, CA ;
Feinstein, JA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 287 (02) :H921-H926
[3]   Inferior vena caval hemodynamics quantified in vivo at rest and during cycling exercise using magnetic resonance imaging [J].
Cheng, CP ;
Herfkens, RJ ;
Taylor, CA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2003, 284 (04) :H1161-H1167
[4]  
CHENG CP, 2005, J MAGN RESON IMAGING, V33, P257
[5]  
DELEVAL MR, 1988, J THORAC CARDIOV SUR, V96, P682
[6]   A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection [J].
Dubini, G ;
deLeval, MR ;
Pietrabissa, R ;
Montevecchi, FM ;
Fumero, R .
JOURNAL OF BIOMECHANICS, 1996, 29 (01) :111-121
[7]   Cardiorespiratory response to exercise after modified fontan operation: Determinants of performance [J].
Durongpisitkul, K ;
Driscoll, DJ ;
Mahoney, DW ;
Wollan, PC ;
Mottram, CD ;
Puga, FJ ;
Danielson, GK .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 29 (04) :785-790
[8]   Fluid mechanic assessment of the total cavopulmonary connection using magnetic resonance phase velocity mapping and digital particle image velocimetry [J].
Ensley, AE ;
Ramuzat, A ;
Healy, TM ;
Chatzimavroudis, GP ;
Lucas, C ;
Sharma, S ;
Pettigrew, R ;
Yoganathan, AP .
ANNALS OF BIOMEDICAL ENGINEERING, 2000, 28 (10) :1172-1183
[9]   Lung function and aerobic capacity in adult patients following modified Fontan procedure [J].
Fredriksen, PM ;
Therrien, J ;
Veldtman, G ;
Warsi, MA ;
Liu, P ;
Siu, S ;
Williams, W ;
Granton, J ;
Webb, G .
HEART, 2001, 85 (03) :295-299
[10]   Noninvasive fluid dynamic power loss assessments for total cavopulmonary connections using the viscous dissipation function: A feasibility study [J].
Healy, TM ;
Lucas, C ;
Yoganathan, AP .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (04) :317-324