A Modified Implant Surgical Guide for the Administration of Maxillary Nerve Block Anesthesia Intraorally via the Greater Palatine Foramen: Case Report

被引:4
作者
Jamjoom, Faris Z. [1 ]
Doliveux, Simon [1 ]
Rousson, Dominique D. [1 ]
Friedland, Bernard [2 ]
Hamilton, Adam [3 ]
机构
[1] Harvard Sch Dent Med, Dept Restorat Dent & Biomat Sci, Boston, MA 02115 USA
[2] Harvard Sch Dent Med, Dept Oral Med Infect & Immun, Boston, MA 02115 USA
[3] Harvard Sch Dent Med, Dept Restorat Dent & Biomat Sci, Div Regenerat & Implant Sci, Boston, MA 02115 USA
关键词
3D; CAD/CAM; local anesthesia; sinus elevation; surgery; surgical guide; COMPUTED-TOMOGRAPHY; ACCURACY;
D O I
10.11607/jomi.7734
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Block anesthesia for the maxillary division (V2) of the trigeminal nerve is a suitable approach when an entire quadrant of teeth and/or associated structures are involved. The most effective approach to anesthetize the maxillary branch is intraorally via the greater palatine canal. This case report describes the use of a computer-aided design/computer-assisted manufacturing (CAD/CAM) implant surgical template designed with a guide channel to allow for the administration of maxillary nerve block through the greater palatine canal.
引用
收藏
页码:1249 / 1254
页数:6
相关论文
共 25 条
[1]   Maxillary nerve block via the greater palatine canal: An old technique revisited [J].
Aoun, Georges ;
Zaarour, Ibrahim ;
Sokhn, Sayde ;
Nasseh, Ibrahim .
JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2015, 5 (05) :359-364
[2]  
ARAVENA TP, 2011, INT J MORPHOL, V29, P857
[3]  
Boyce Ricardo A, 2016, Dent Clin North Am, V60, P445, DOI 10.1016/j.cden.2015.12.001
[4]   Digital technology for performing a nasopalatine and greater palatine nerve block with a modified implant surgical guide: A technique article [J].
Dahiya, Ankur ;
Garbacea, Antoanela ;
Kattadiyil, Mathew T. ;
AlHelal, Abdulaziz .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03) :338-342
[5]   The influence of guided sleeve height, drilling distance, and drilling key length on the accuracy of static Computer-Assisted Implant Surgery [J].
El Kholy, Karim ;
Janner, Simone F. M. ;
Schimmel, Martin ;
Buser, Daniel .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (01) :101-107
[6]   A 3D-printed guide for lateral approach sinus grafting: A dental technique [J].
Goodacre, Brian J. ;
Swamidass, Rajesh S. ;
Lozada, Jaime ;
Al-Ardah, Aladdin ;
Sahl, Erik .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (06) :897-901
[7]  
Hawkins J M, 1998, J Calif Dent Assoc, V26, P658
[8]  
Hawkins J Mel, 2002, Dent Clin North Am, V46, P719, DOI 10.1016/S0011-8532(02)00020-4
[9]   New supplemental landmark for the greater palatine foramen as found deep to soft tissue: application for the greater palatine nerve block [J].
Iwanaga, Joe ;
Voin, Vlad ;
Nasseh, Allen Ali ;
Kido, Junta ;
Tsukiyama, Teppei ;
Kamura, Yasuhiko ;
Tanaka, Tsuyoshi ;
Fisahn, Christian ;
Alonso, Fernando ;
Oskouian, Rod J. ;
Tubbs, R. Shane .
SURGICAL AND RADIOLOGIC ANATOMY, 2017, 39 (09) :981-984
[10]   Positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan using surface scan registration [J].
Jamjoom, Faris Z. ;
Kim, Do-Gyoon ;
McGlumphy, Edwin A. ;
Lee, Damian J. ;
Yilmaz, Burak .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (03) :367-374