Whole-Heart Imaging Using Undersampled Radial Phase Encoding (RPE) and Iterative Sensitivity Encoding (SENSE) Reconstruction

被引:23
作者
Boubertakh, R. [1 ]
Prieto, C. [1 ]
Batchelor, P. G. [1 ]
Uribe, S. [1 ]
Atkinson, D. [2 ]
Eggers, H. [3 ]
Sorensen, T. S. [4 ,5 ]
Hansen, M. S. [6 ]
Razavi, R. S. [1 ]
Schaeffter, T. [1 ]
机构
[1] Kings Coll London, British Heart Fdn BHF Ctr, Guys & St Thomas Natl Hlth Serv NHS Fdn Trust, Natl Inst Hlth Res,Biomed Res Ctr,Div Imaging Sci, London WC2R 2LS, England
[2] UCL, Ctr Med Image Comp, London, England
[3] Philips Res Europe, Hamburg, Germany
[4] Univ Aarhus, Dept Comp Sci, Aarhus, Denmark
[5] Univ Aarhus, Inst Clin Med, Aarhus, Denmark
[6] UCL, Inst Child Hlth, London, England
基金
英国工程与自然科学研究理事会;
关键词
whole-heart MRI; radial-Cartesian sampling; iterative SENSE reconstruction; parallel imaging; 32 channel coil; radical phase encoding; CORONARY MR-ANGIOGRAPHY; MAGNETIC-RESONANCE ANGIOGRAPHY; COMMODITY GRAPHICS HARDWARE; K-SPACE; SPATIAL-RESOLUTION;
D O I
10.1002/mrm.22102
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Whole-heart isotropic nonangulated cardiac magnetic resonance (CMR) is becoming an important protocol in simplifying MRI, since it reduces the need of cumbersome planning of angulations. However the acquisition times of whole-heart MRI are prohibitive due to the large fields of view (FOVs) and the high spatial resolution required for depicting small structures and vessels. To address this problem, we propose a three-dimensional (3D) acquisition scheme that combines Cartesian sampling in the readout direction with an undersampled radial scheme in the phase-encoding plane. Different undersampling patterns were investigated in combination with an iterative sensitivity encoding (SENSE) reconstruction and a 32-channel cardiac coil. Noise amplification maps were calculated to compare the performance of the different patterns using iterative SENSE reconstruction. The radial phase-encoding (RPE) scheme was implemented on a clinical MR scanner and tested on phantoms and healthy volunteers. The proposed method exhibits better image quality even for high acceleration factors (up to 12) in comparison to Cartesian acquisitions. Magn Reson Med 62: 1331-1337, 2009. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:1331 / 1337
页数:7
相关论文
共 24 条
[1]  
EGGERS H, 2005, P 13 ANN M ISMRM MIA
[2]  
EGGERS H, 2008, P 16 ANN M ISMRM TOR
[3]   Soap-bubble visualization and quantitative analysis of 3D coronary magnetic resonance angiograms [J].
Etienne, A ;
Botnar, RM ;
van Muiswinkel, AMC ;
Boesiger, P ;
Manning, WJ ;
Stuber, M .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :658-666
[4]   PROJECTION RECONSTRUCTION TECHNIQUES FOR REDUCTION OF MOTION EFFECTS IN MRI [J].
GLOVER, GH ;
PAULY, JM .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :275-289
[5]   Cartesian SENSE and k-t SENSE reconstruction using commodity graphics hardware [J].
Hansen, Michael S. ;
Atkinson, David ;
Sorensen, Thomas S. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (03) :463-468
[6]   Three-dimensional reconstruction of limited-view projections for contrast-enhanced magnetic resonance angiography at high temporal and spatial resolution [J].
Huang, YX ;
Gurr, D ;
Wright, GA .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) :68-74
[7]  
KING K, 2005, MAGN RESON MED, V39, P448
[8]   Coronary MRA with 3D undersampled projection reconstruction TrueFISP [J].
Larson, AC ;
Simonetti, OP ;
Li, DB .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (04) :594-601
[9]   Effects of polar sampling in k-space [J].
Lauzon, ML ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :940-949
[10]   Undersampled elliptical centric view-order for improved spatial resolution in contrast-enhanced MR angiography [J].
Madhuranthakam, AJ ;
Hu, HCH ;
Barger, AV ;
Haider, CR ;
Kruger, DG ;
Glockner, JF ;
Huston, J ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) :50-58