Flow-injection determination of chromium(III) by its catalysis on the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone with N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methoxyaniline

被引:28
作者
Kaneko, M
Kurihara, M
Nakano, S
Kawashima, T
机构
[1] Tottori Univ, Fac Educ & Reg Sci, Dept Environm Sci, Tottori 6808551, Japan
[2] Univ Tsukuba, Dept Chem, Analyt Chem Lab, Tsukuba, Ibaraki 3058571, Japan
关键词
chromium(III) and total chromium determination; catalysis; spectrophotometry; flow injection analysis; speciation;
D O I
10.1016/S0003-2670(02)01005-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection photometric method was developed for the determination of trace amounts of chromium(III). It is based on its catalytic action on the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone with N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3-methoxyaniline as a modified Trinder's reagent to produce an intensely colored dye (lambda(max) = 568 nm) in the presence of hydrogen peroxide at pH 7.0-7.3. In this reaction, ethylenediamine-N,N,N',N'-tetraacetic acid (EDTA), diethylenetriamine-N,N,N',N",N"-pentaacetic acid (DTPA) and 1,2-dihydroxy-3,5-benzenedisulfonic acid (Tiron) acted as activators for the catalysis of chromium(III); among them EDTA showed the most effective action for the catalysis of chromium(HI). Dynamic range was 5-400 ng ml(-1) of chromium(III) at a sampling rate of 25 h(-1) in the presence of EDTA. The relative standard deviations (R.S.D.) for 40 and 100 ng ml(-1) chromium(M) (n = 10) were 0.94 and 0.83%, respectively. The chromium(VI) in sample solution can be determined by reducing to chromium(III) by hydrogen peroxide in an acidic medium, which allows total chromium determination. The proposed method was successfully applied to the determination of chromium in certified reference materials of vehicle exhaust particulates (NIES no. 8) and river water (JSAC-0032). (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:167 / 176
页数:10
相关论文
共 35 条
[1]   MUTUAL CATALYSIS IN THE CHROMIUM(III)-EDTA HYDROGEN PEROXIDE SYSTEM [J].
BECK, MT ;
TOTH, Z .
BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1979, 52 (02) :598-600
[2]   INVESTIGATION OF CHROMIUM(III) AND CHROMIUM(VI) SPECIATION IN WATER BY ION CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION [J].
BEERE, HG ;
JONES, P .
ANALYTICA CHIMICA ACTA, 1994, 293 (03) :237-243
[3]  
DOLMANOV.IF, 1970, J ANAL CHEM-USSR+, V25, P2136
[4]  
DOLMANOVA IF, 1978, ZH ANAL KHIM, V33, P274
[5]  
DOLMANOVA IF, 1969, ZH ANAL KHIM, V24, P1035
[6]   FLOW-INJECTION CHEMILUMINESCENCE METHOD FOR THE SELECTIVE DETERMINATION OF CHROMIUM(III) [J].
ESCOBAR, R ;
LIN, QX ;
GUIRAUM, A ;
DELAROSA, FF .
ANALYST, 1993, 118 (06) :643-647
[7]   Determination of trivalent and hexavalent chromium in waste water by flow injection chemiluminescence analysis [J].
Escobar, R ;
Lin, Q ;
Guiraum, A ;
DeLaRosa, FF .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1995, 61 (03) :169-175
[8]   Catalytic determination of cobalt at sub-nanogram levels using the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone with N-ethyl-N-(2-hydroxy-3-sulfopropyl)-3,5-dimethoxyaniline by manual and flow-injection methods [J].
Fujimoto, T ;
Teshima, N ;
Kurihara, M ;
Nakano, S ;
Kawashima, T .
TALANTA, 1999, 49 (05) :1091-1098
[9]   REACTIONS OF HYDROGEN-PEROXIDE WITH METAL-COMPLEXES .3. THERMODYNAMIC AND KINETIC STUDIES ON FORMATION, DISSOCIATION, AND DECOMPOSITION OF PEROXOCHROMIUM(VI) COMPLEXES IN ACID-MEDIA [J].
FUNAHASHI, S ;
UCHIDA, F ;
TANAKA, M .
INORGANIC CHEMISTRY, 1978, 17 (10) :2784-2789