Metrological parameters of sulphur dioxide amperometric sensor containing addition of aprotic solvents

被引:7
作者
Gebicki, J. [1 ]
Chachulski, B. [1 ]
机构
[1] Gdansk Univ Technol, Fac Chem, Dept Chem & Proc Engn, PL-80233 Gdansk, Poland
关键词
Solid polymer electrolyte (SPE); Amperometric sensor; Aprotic solvents; MICROELECTRODE GAS SENSORS; DIMETHYL-SULFOXIDE; CO2; REDUCTION; ELECTRODES; GOLD; HYDROCARBONS; ODYSSEY; SAMPLES; O-2;
D O I
10.1016/j.snb.2009.06.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The paper presents the results of investigation on influence of aprotic solvents contained in ail internal electrolyte on metrological parameters of a prototype of sulphur dioxide sensor with Nafion membrane. Five sensors differing in composition of the internal electrolyte have been compared. Gold electrode vucuum sublimation deposited on the Nafion membrane Surface was a working electrode. The electrolytes were aqueous solutions of sulphuric acid of the Summary concentration 5 mol dm(-3) (electrolyte A). The electrolyte B contained ail addition of dimethylsulphoxide (DIVISC), the electrolyte C contained an addition of N,N-dimethylformamide (DMF), the electrolyte D contained an addition of acetonitrile (AC) and the electrolyte E contained ail addition of propylene carbonate (PC) water/solvent molar ratio in these solutions was 2: 1. Based oil a proposed equation ail influence of the analyte flow rate on the sensor signal and response time to changes Of SO2 concentration was investigated. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 25 条
[1]   Amperometric sulfur dioxide gas sensor with dimethyl sulfoxide as solvent for internal electrolyte solution [J].
Chachulski, B .
ANALYST, 1998, 123 (05) :1141-1144
[2]   Influence of aprotic solvent on a signal of an amperometric sensor with Nafion® membrane [J].
Chachulski, B. ;
Gebicki, J. .
SENSORS AND ACTUATORS B-CHEMICAL, 2006, 119 (02) :435-440
[3]  
Chachulski B, 2004, CHEM ANAL-WARSAW, V49, P803
[4]   AMBIENT-TEMPERATURE GAS-PHASE CO2 REDUCTION TO HYDROCARBONS AT SOLID POLYMER ELECTROLYTE CELLS [J].
COOK, RL ;
MACDUFF, RC ;
SAMMELLS, AF .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1988, 135 (06) :1470-1471
[5]  
Fatt I., 1976, Polarographic Oxygen Sensors
[6]   DETERMINATION OF ATMOSPHERIC SULFUR-DIOXIDE BY DIFFERENTIAL PULSE POLAROGRAPHY [J].
GARBER, RW ;
WILSON, CE .
ANALYTICAL CHEMISTRY, 1972, 44 (08) :1357-&
[7]   Impedance investigations of amperometric gas sensor containing aprotic solvent [J].
Gebicki, J. ;
Chachulski, R. .
ELECTROANALYSIS, 2006, 18 (24) :2413-2420
[8]  
Gnaiger E., 1983, POLAROGRAPHIC OXYGEN
[9]   THE DEVELOPMENT OF NEW MICROELECTRODE GAS SENSORS - AN ODYSSEY .1. O-2 AND CO2 REDUCTION AT UNSHIELDED GOLD MICRODISK ELECTRODES [J].
HAHN, CEW ;
MCPEAK, H ;
BOND, AM ;
CLARK, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 393 (1-2) :61-68
[10]  
Hahn CEW, 1998, ANALYST, V123, p57R