Head-Up Tilt Rapidly Compromises Hemodynamics in Healthy Anesthetized Swine

被引:2
|
作者
Mlcek, M. [1 ]
Belohlavek, J. [2 ]
Huptych, M. [3 ]
Boucek, T. [2 ]
Belza, T. [2 ]
Lacko, S. [1 ]
Krupickova, P. [2 ]
Hrachovina, M. [3 ]
Popkova, M. [1 ]
Neuzil, P. [4 ]
Kittnar, O. [1 ]
机构
[1] Charles Univ Prague, Fac Med 1, Inst Physiol, Albertov 5, Prague 12800 2, Czech Republic
[2] Charles Univ Prague, Fac Med 1, Dept Med 2, Prague 12800 2, Czech Republic
[3] Czech Tech Univ, Fac Elect Engn, Dept Cybernet, CR-16635 Prague, Czech Republic
[4] Na Homolce Hosp, Dept Cardiol, Prague, Czech Republic
关键词
Head-up tilt; Hemodynamics; Pressure-volume loop / Cardiac output; Swine; Oximetry; POSITION; FLOW;
D O I
10.33549/physiolres.933229
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The aims were to explore the effect of head-up tilt (HUT) to 30 and 60 degrees on hemodynamics and tissue oxygenation in anesthetized healthy swine. The data serve as a reference for a study of resuscitation efficacy at HUT such as during transport. Nine healthy swine (49 +/- 4 kg) were anesthetized and multiple sensors including myocardial pressure-volume loops catheter, carotid flow probe, blood pressure catheters, near infrared spectroscopy (NIRS) tissue oximetry and mixed venous oximetry (SVO2) catheter were introduced and parameters continuously recorded. Experimental protocol consisted of baseline in supine position (15 min), 30 degrees HUT (15 min), recovery at supine position (15 min) and 60 degrees HUT (5 min). Vacuum mattress was used for body fixation during tilts. We found that 30 and 60 degrees inclination led to significant immediate reduction in hemodynamic and oximetry parameters. Mean arterial pressure (mm Hg) decreased from 98 at baseline to 53 and 39, respectively. Carotid blood flow dropped to 47 % and 22 % of baseline values, end diastolic volume to 49 % and 53 % and stroke volume to 47 % and 45 % of baseline. SVO2 and tissue oximetry decreased by 17 and 21 percentage points. The values are means. In conclusions, within minutes, both 30 and 60 degrees head-up tilting is poorly tolerated in anesthetized swine. Significant differences among individual animals exist.
引用
收藏
页码:S677 / S683
页数:7
相关论文
共 50 条
  • [31] Leg vasoconstriction during head-up tilt in patients with autonomic failure is not abolished
    Groothuis, Jan T.
    Thijssen, Dick H. J.
    Lenders, Jacques W. M.
    Deinum, Jaap
    Hopman, Maria T. E.
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 110 (02) : 416 - 422
  • [32] What is the minimum duration of head-up tilt necessary to detect orthostatic hypotension?
    Gehrking, JA
    Hines, SM
    Benrud-Larson, LM
    Opher-Gehrking, TL
    Low, PA
    CLINICAL AUTONOMIC RESEARCH, 2005, 15 (02) : 71 - 75
  • [33] Carotid duplex ultrasonography during head-up tilt in patients with orthostatic hypotension
    Hamaguchi, Tsuyoshi
    Iwasa, Kazuo
    Okino, Soichi
    Yamada, Masahito
    EUROPEAN NEUROLOGY, 2007, 57 (04) : 219 - 222
  • [34] An optimal control approach for blood pressure regulation during head-up tilt
    Nakeya D. Williams
    Jesper Mehlsen
    Hien T. Tran
    Mette S. Olufsen
    Biological Cybernetics, 2019, 113 : 149 - 159
  • [35] Hemodynamic Response to Head-Up Tilt of Patients Implanted with Biventricular Assist Device
    Nadeem, K.
    Lim, E.
    Ng, B. C.
    Mubin, M.
    INTERNATIONAL CONFERENCE FOR INNOVATION IN BIOMEDICAL ENGINEERING AND LIFE SCIENCES, ICIBEL2015, 2016, 56 : 150 - 154
  • [36] The effect of age on cerebrovascular reactivity to cold pressor test and head-up tilt
    Oblak, JP
    Zaletel, M
    Zvan, B
    Kiauta, T
    Pogacnik, T
    ACTA NEUROLOGICA SCANDINAVICA, 2002, 106 (01): : 30 - 33
  • [37] Hemodynamic alterations in hypertensive patients at rest and during passive head-up tilt
    Tikkakoski, Antti J.
    Tahvanainen, Anna M.
    Leskinen, Miia H.
    Koskela, Jenni K.
    Haring, Antti
    Viitala, Jani
    Kahonen, Mika A. P.
    Koobi, Tiit
    Niemela, Onni
    Mustonen, Jukka T.
    Porsti, Ilkka H.
    JOURNAL OF HYPERTENSION, 2013, 31 (05) : 906 - 915
  • [38] Increased Aldosterone Release During Head-Up Tilt in Early Primary Hypertension
    Reinold, Annemarie
    Schneider, Andreas
    Kalizki, Tatjana
    Raff, Ulrike
    Schneider, Markus P.
    Schmieder, Roland E.
    Schmidt, Bernhard M. W.
    AMERICAN JOURNAL OF HYPERTENSION, 2017, 30 (05) : 484 - 489
  • [39] Frontal lobe hemodynamics detected by functional near-infrared spectroscopy during head-up tilt table tests in patients with electrical burns
    Kim, Yoo Hwan
    Kim, Youngmin
    Yoon, Jaechul
    Cho, Yong Suk
    Kym, Dohern
    Hur, Jun
    Chun, Wook
    Kim, Byung-Jo
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [40] Arterial blood pressure response to head-up tilt test and orthostatic tolerance in nurses
    Onizuka, Chisato
    Niimi, Yuki
    Sato, Motohiko
    Sugenoya, Junichi
    ENVIRONMENTAL HEALTH AND PREVENTIVE MEDICINE, 2015, 20 (04) : 262 - 270