Head-Up Tilt Rapidly Compromises Hemodynamics in Healthy Anesthetized Swine

被引:2
|
作者
Mlcek, M. [1 ]
Belohlavek, J. [2 ]
Huptych, M. [3 ]
Boucek, T. [2 ]
Belza, T. [2 ]
Lacko, S. [1 ]
Krupickova, P. [2 ]
Hrachovina, M. [3 ]
Popkova, M. [1 ]
Neuzil, P. [4 ]
Kittnar, O. [1 ]
机构
[1] Charles Univ Prague, Fac Med 1, Inst Physiol, Albertov 5, Prague 12800 2, Czech Republic
[2] Charles Univ Prague, Fac Med 1, Dept Med 2, Prague 12800 2, Czech Republic
[3] Czech Tech Univ, Fac Elect Engn, Dept Cybernet, CR-16635 Prague, Czech Republic
[4] Na Homolce Hosp, Dept Cardiol, Prague, Czech Republic
关键词
Head-up tilt; Hemodynamics; Pressure-volume loop / Cardiac output; Swine; Oximetry; POSITION; FLOW;
D O I
10.33549/physiolres.933229
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The aims were to explore the effect of head-up tilt (HUT) to 30 and 60 degrees on hemodynamics and tissue oxygenation in anesthetized healthy swine. The data serve as a reference for a study of resuscitation efficacy at HUT such as during transport. Nine healthy swine (49 +/- 4 kg) were anesthetized and multiple sensors including myocardial pressure-volume loops catheter, carotid flow probe, blood pressure catheters, near infrared spectroscopy (NIRS) tissue oximetry and mixed venous oximetry (SVO2) catheter were introduced and parameters continuously recorded. Experimental protocol consisted of baseline in supine position (15 min), 30 degrees HUT (15 min), recovery at supine position (15 min) and 60 degrees HUT (5 min). Vacuum mattress was used for body fixation during tilts. We found that 30 and 60 degrees inclination led to significant immediate reduction in hemodynamic and oximetry parameters. Mean arterial pressure (mm Hg) decreased from 98 at baseline to 53 and 39, respectively. Carotid blood flow dropped to 47 % and 22 % of baseline values, end diastolic volume to 49 % and 53 % and stroke volume to 47 % and 45 % of baseline. SVO2 and tissue oximetry decreased by 17 and 21 percentage points. The values are means. In conclusions, within minutes, both 30 and 60 degrees head-up tilting is poorly tolerated in anesthetized swine. Significant differences among individual animals exist.
引用
收藏
页码:S677 / S683
页数:7
相关论文
共 50 条
  • [21] High variability in the reproducibility of key hemodynamic responses to head-up tilt
    Bouquin, Heidi
    Suojanen, Lauri J.
    Koskela, Jenni K.
    Pietila, Essi
    Choudhary, Manoj Kumar
    Mustonen, Jukka T.
    Porsti, Ilkka H.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2025, 328 (03): : H387 - H392
  • [22] Head-up tilt table test: How far and how long?
    Khurana, RK
    Nicholas, EM
    CLINICAL AUTONOMIC RESEARCH, 1996, 6 (06) : 335 - 341
  • [23] Cardiac autonomic responses to progressive head-up tilt in individuals with paraplegia
    Wecht, JM
    De Meersman, RE
    Weir, JP
    Spungen, AM
    Bauman, WA
    CLINICAL AUTONOMIC RESEARCH, 2003, 13 (06) : 433 - 438
  • [24] IS ABSOLUTE HYPOVOLEMIA A RISK FACTOR FOR VASOVAGAL RESPONSE TO HEAD-UP TILT
    JAEGER, FJ
    MALONEY, JD
    CASTLE, LW
    FOUADTARAZI, FM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (04): : 743 - 750
  • [25] Impedance rheography of vascular response to head-up tilt maneuver in tetraplegia
    Pils, K
    Pils, P
    PERFUSION, 2000, 13 (09): : 380 - 382
  • [26] Blunted autonomic response to standing up and head-up tilt in individuals with intellectual disabilities
    Hilgenkamp, Thessa I. M.
    Lefferts, Elizabeth C.
    White, Daniel W.
    Baynard, Tracy
    Fernhall, Bo
    JOURNAL OF APPLIED PHYSIOLOGY, 2021, 130 (06) : 1778 - 1785
  • [27] Cardiac autonomic responses to progressive head-up tilt in individuals with paraplegia
    Jill M. Wecht
    Ronald E. De Meersman
    Joseph P. Weir
    Ann M. Spungen
    William A. Bauman
    Clinical Autonomic Research, 2003, 13 : 433 - 438
  • [28] Comparison of the sit-up test and head-up tilt test for assessing blood pressure and hemodynamic responses in healthy young individuals
    Oyake, Kazuaki
    Murayama, Jun
    Tateishi, Takaki
    Mochida, Ayumi
    Matsumoto, Mao
    Tsujikawa, Masahiro
    Kondo, Kunitsugu
    Otaka, Yohei
    Momose, Kimito
    BLOOD PRESSURE MONITORING, 2022, 27 (02) : 79 - 86
  • [29] Cardiovascular and humoral readjustment after different levels of head-up tilt in humans
    László, Z
    Rössler, A
    Hinghofer-Szalkay, HG
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 2001, 72 (03): : 193 - 201
  • [30] What is the minimum duration of head-up tilt necessary to detect orthostatic hypotension?
    Jade A. Gehrking
    Stacy M. Hines
    Lisa M. Benrud-Larson
    Tonette L. Opher-Gehrking
    Phillip A. Low
    Clinical Autonomic Research, 2005, 15 : 71 - 75