Comparison of Current Control Strategies Based on FCS-MPC and D-PI-PWM Control for Actively Damped VSCs With LCL-Filters

被引:17
作者
Lim, Chee Shen [1 ]
Lee, Sze Sing [2 ]
Wong, Yi Chyn Cassandra [1 ]
Nutkani, Inam Ullah [3 ]
Goh, Hui Hwang [4 ]
机构
[1] Univ Southampton Malaysia, Iskandar Puteri 79200, Malaysia
[2] Newcastle Univ Singapore, Newcastle Res & Innovat Inst, Singapore 609607, Singapore
[3] RMIT Univ, Sch Engn, Melbourne, Vic 3000, Australia
[4] Guangxi Univ, Sch Elect Engn, Nanning 530015, Peoples R China
关键词
Model predictive control; cost function; LCL filter; active damping; derivative voltage feedback; MODEL-PREDICTIVE CONTROL; GRID-CONNECTED INVERTER; SYSTEMATIC DESIGN; ROBUSTNESS; CONVERTERS;
D O I
10.1109/ACCESS.2019.2934185
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a comparative study of the proportional-integral-based (PI-based) synchronous current control strategy with derivative-feedback-based active damping and the finite-control-set model-predictive-control-based (FCS-MPC-based) synchronous current control strategy with cost-function-based active damping. For a fair comparison, the sensor requirement and the average switching frequency of FCS-MPC are made equivalent to that of the pulse-width-modulation-based counterpart through internal model estimation and control sampling frequency adjustment. The comparative study considers gain/weighting-factor tuning, delay compensation, switching harmonics, and active damping performance at the critical frequency operating point. The overall performance of both schemes is validated through the same experimental setup and test scenarios. The results conclude that the emerging FCS-MPC has the potential to produce similar results as the classical PI-based counterpart while carrying some practical features. These include being intuitive in active damping design and tuning, guaranteeing fast dynamics, and being sufficiently robust to grid impedance shifting. These findings essentially justify the potential of model predictive control being a viable alternative for this area of application.
引用
收藏
页码:112410 / 112423
页数:14
相关论文
共 33 条
[1]   Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[2]   Filter-Based Active Damping of Voltage Source Converters With LCL Filter [J].
Dannehl, Joerg ;
Liserre, Marco ;
Fuchs, Friedrich Wilhelm .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2011, 58 (08) :3623-3633
[3]   Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters [J].
Dannehl, Joerg ;
Fuchs, Friedrich Wilhelm ;
Hansen, Steffan ;
Thogersen, Paul Bach .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2010, 46 (04) :1509-1517
[4]   Finite Control Set Model Predictive Control for Grid-Connected AC-DC Converters With LCL Filter [J].
Falkowski, Piotr ;
Sikorski, Andrzej .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2018, 65 (04) :2844-2852
[5]   Inverter-Side Current Control of Grid-Connected Voltage Source Inverters With LCL Filter Based on Generalized Predictive Control [J].
Gabriel Judewicz, Marcos ;
Alejandro Gonzalez, Sergio ;
Roberto Fischer, Jonatan ;
Francisco Martinez, Juan ;
Oscar Carrica, Daniel .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) :1732-1743
[6]   Receding-Horizon Model-Predictive Control for a Three-Phase VSI With an LCL Filter [J].
Guzman, Ramon ;
Garcia de Vicuna, Luis ;
Camacho, Antonio ;
Miret, Jaume ;
Rey, Juan M. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2019, 66 (09) :6671-6680
[7]   Passivity-Based Controller Design of Grid-Connected VSCs for Prevention of Electrical Resonance Instability [J].
Harnefors, Lennart ;
Yepes, Alejandro G. ;
Vidal, Ana ;
Doval-Gandoy, Jesus .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (02) :702-710
[8]   Capacitor-Current Proportional-Integral Positive Feedback Active Damping for LCL-Type Grid-Connected Inverter to Achieve High Robustness Against Grid Impedance Variation [J].
He, Yuying ;
Wang, Xuehua ;
Ruan, Xinbo ;
Pan, Donghua ;
Xu, Xingping ;
Liu, Fuxin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (12) :12423-12436
[9]   Internal Model-Based Active Resonance Damping Current Control of a Grid-Connected Voltage-Sourced Converter With an LCL Filter [J].
Leitner, Stefan ;
Yazdanian, Mehrdad ;
Ziaeinejad, Saleh ;
Mehrizi-Sani, Ali ;
Muetze, Annette .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (06) :6025-6036
[10]   Wide Damping Region for LCL-Type Grid-Connected Inverter With an Improved Capacitor-Current-Feedback Method [J].
Li, Xiaoqiang ;
Wu, Xiaojie ;
Geng, Yiwen ;
Yuan, Xibo ;
Xia, Chenyang ;
Zhang, Xue .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (09) :5247-5259