A review on the application of Trombe wall system in buildings

被引:204
作者
Hu, Zhongting [1 ]
He, Wei [2 ]
Ji, Jie [1 ]
Zhang, Shengyao [3 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Peoples R China
[2] Hefei Univ Technol, Dept Bldg Environm & Equipment, Hefei 230009, Peoples R China
[3] Guangdong Five Star Solar Energy Co Ltd, Dongguan 523051, Peoples R China
关键词
Trombe wall; Building; Heating; Cooling; Trombe-wall efficiency; THERMAL-ENERGY STORAGE; PHASE-CHANGE MATERIALS; SOLAR CHIMNEY; SENSITIVITY-ANALYSIS; HEAT-TRANSFER; AIR-FLOW; PERFORMANCE; DESIGN; OPTIMIZATION; SIMULATION;
D O I
10.1016/j.rser.2016.12.003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A major portion of the total primary energy consumed by today's buildings is used in heating, ventilating, and air-conditioning (HVAC). Conventional heating and cooling systems are having an impact on operational cost, energy requirement and carbon dioxide emission. In this regard, Trombe walls are receiving considerable attention because of their potential ability for addressing the environmental and energy crisis. This paper reviews the most pertinent contents of studies on Trombe walls that have been carried out in the recent 15 years. According to utilizing functions of Trombe walls, they are divided into two major types: a heating-based type and a cooling-based type. In terms of content, we emphasize the introduction of three groups of parameters that be considered when designing Trombe walls: the 'Trombe wall' parameters, the `building' parameters and the 'site' parameters. Then different evaluation indicators on Trombe walls have been summarized from three points of view: energy, environment and economic. We hope that this review is useful to academic researchers and can provide a reference for architects or related engineering designers in the field of passive design.
引用
收藏
页码:976 / 987
页数:12
相关论文
共 84 条
[1]   Energetic study of a Trombe wall system under different Tunisian building configurations [J].
Abbassi, Fakhreddine ;
Dimassi, Narjes ;
Dehmani, Leila .
ENERGY AND BUILDINGS, 2014, 80 :302-308
[2]  
Adams S, 2010, SOLAR C COL ASES2010
[3]  
Agrawal B, 2011, RSC ENERGY SER, P1
[4]   Optimization and life-cycle cost of health clinic PV system for a rural area in southern Iraq using HOMER software [J].
Al-Karaghouli, Ali ;
Kazmerski, L. L. .
SOLAR ENERGY, 2010, 84 (04) :710-714
[5]   SOLAR HEAT GAIN FACTORS AND HEAT-LOSS COEFFICIENTS FOR PASSIVE HEATING CONCEPTS [J].
BHANDARI, MS ;
BANSAL, NK .
SOLAR ENERGY, 1994, 53 (02) :199-208
[6]  
Bin C, 2006, REN EN P
[7]   Optimizing energy and environmental performance of passive Trombe wall [J].
Bojic, Milorad ;
Johannes, Kevyn ;
Kuznik, Frederic .
ENERGY AND BUILDINGS, 2014, 70 :279-286
[8]   Energy performance of Trombe walls: Adaptation of ISO 13790:2008(E) to the Portuguese reality [J].
Briga-Sa, Ana ;
Martins, Analisa ;
Boaventura-Cunha, Jose ;
Lanzinha, Joao Carlos ;
Paiva, Anabela .
ENERGY AND BUILDINGS, 2014, 74 :111-119
[9]   Air flow and thermal efficiency characteristics in solar chimneys and Trombe Walls [J].
Burek, S. A. M. ;
Habeb, A. .
ENERGY AND BUILDINGS, 2007, 39 (02) :128-135
[10]   Use of microencapsulated PCM in concrete walls for energy savings [J].
Cabeza, Luisa F. ;
Castellon, Cecilia ;
Nogues, Miquel ;
Medrano, Marc ;
Leppers, Ron ;
Zubillaga, Oihana .
ENERGY AND BUILDINGS, 2007, 39 (02) :113-119