MRI-guided treatment-planning optimisation in intracavitary or combined intracavitary/interstitial PDR brachytherapy using tandem ovoid applicators in locally advanced cervical cancer

被引:95
作者
Jurgenliemk-Schulz, Ina M. [1 ]
Tersteeg, Robbert J. H. A. [1 ]
Roesink, Judith M. [1 ]
Bijmolt, Stefan [1 ]
Nomden, Christel N. [1 ]
Moerland, Marinus A. [1 ]
de Leeuw, Astrid A. C. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiat Oncol, NL-3584 CX Utrecht, Netherlands
关键词
PDR brachytherapy; Treatment-planning optimisation; Cervical cancer; MRI based; DOSE-VOLUME HISTOGRAMS; GYNECOLOGIC MALIGNANCIES; INTERSTITIAL BRACHYTHERAPY; RADIATION-THERAPY; EXTERNAL-BEAM; WORKING GROUP; HDR-BRACHYTHERAPY; VIENNA APPLICATOR; REFERENCE-POINT; SMALL-BOWEL;
D O I
10.1016/j.radonc.2009.08.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To study the impact of MRI-guided treatment planning on dose/volume parameters in pulsed dose rate (PDR) brachytherapy (BT) for cervical cancer. Additionally, we investigated the potential benefit of an intracavitary/interstitial (IC/IS) modification of the classical tandem ovoid applicator. Material and methods: For 24 patients we compared Standard PDR BT plans, Scaled Standard plans and MRI-guided Optimised plans. The total EBRT/BT prescribed dose to Manchester point A or to 90% of the HR-CTV (D90 HR-CTV) [1] expressed in EQD(2) was 80 Gy(alpha beta 10) in 17 patients (Period 1) and 84 Gy(alpha beta 10) in 7 patients (Period II). The constraints to 2 cm(3) of the OAR were 90 Gy(alpha beta 3) for bladder and 75 Gy(alpha beta 3) for rectum, sigmoid and bowel. Most cases were treated with a traditional intracavitary tandem ovoid applicator. In 6 patients we used a newly designed combined IC/IS modification for the second PDR fraction and investigated the benefit of the interstitial part. Results: The average gain of MRI-guided optimisation expressed in D90 HR-CTV was 4 +/- 9 Gy(alpha beta 10) (p < 0.001) and 10 +/- 7 Gy(alpha beta 10) (p = 0.003) in the two periods. The dose to 2 cm3 of the OAR met the constraints. In the group that was treated with the combined IC/IS approach, we could increase the D90 HR-CTV for the second PDR fraction with 5.4 +/- 4.2 Gy(alpha beta 10) (p =0.005) and the D100 with 4.8 +/- 3.1 Gy(alpha beta 10) (p = 0.07). Conclusions: Three-dimensional MRI-guided treatment planning and optimisation improves the DVH parameters compared to conventional planning strategies. Additional improvement can be achieved by using a combined IC/IS approach. (C) 2009 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and oncology 93 (2009) 322-330
引用
收藏
页码:322 / 330
页数:9
相关论文
共 37 条
  • [1] The dose-volume relationship of acute small bowel toxicity from concurrent 5-FU-based chemotherapy and radiation therapy for rectal cancer
    Baglan, KL
    Frazier, RC
    Yan, D
    Huang, RR
    Martinez, AA
    Robertson, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (01): : 176 - 183
  • [2] Bahena JH, 1998, INT J RADIAT ONCOL, V41, P13
  • [3] Bol GH, 2003, PHYS MEDICA, V19, P80
  • [4] DEBRABANDERE M, 2008, RADIOTHER ONCOL
  • [5] DELEEUW AAC, 2009, RADIOTHER ONCOL, DOI DOI 10.1016/JLRADONC.2009.05.00
  • [6] The Vienna applicator for combined intracavitary and interstitial brachytherapy of cervical cancer:: Clinical feasibility and preliminary results
    Dimopoulos, Johannes C. A.
    Kirisits, Christian
    Petric, Primoz
    Georg, Petra
    Lang, Stefan
    Berger, Daniel
    Poetter, Richard
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (01): : 83 - 90
  • [7] Erickson B, 1997, J SURG ONCOL, V66, P285, DOI 10.1002/(SICI)1096-9098(199712)66:4<285::AID-JSO14>3.3.CO
  • [8] 2-T
  • [9] COMBINED RADIOTHERAPY AND SURGERY - LOCAL-CONTROL AND COMPLICATIONS IN EARLY CARCINOMA OF THE UTERINE CERVIX - THE VILLEJUIF EXPERIENCE, 1975-1984
    GERBAULET, AL
    KUNKLER, IH
    KERR, GR
    HAIE, C
    MICHEL, G
    PRADE, M
    LHOMME, C
    MASSELOT, M
    ALBANO, M
    DUTREIX, A
    CHASSAGNE, D
    [J]. RADIOTHERAPY AND ONCOLOGY, 1992, 23 (02) : 66 - 73
  • [10] SOURCE CONFIGURATION AND DOSE-RATES FOR THE SELECTRON AFTERLOADING EQUIPMENT FOR GYNECOLOGIC APPLICATORS
    GRIGSBY, PW