Comparative study on the performance and exergy efficiency of a solar hybrid heat pump using R22 and R744

被引:14
|
作者
Cho, Honghyun [1 ]
机构
[1] Chosun Univ, Dept Mech Engn, Gwangju 501759, South Korea
关键词
Solar; Heat pump; Exergy; Carbon dioxide; COP; ENERGY-STORAGE; SYSTEM;
D O I
10.1016/j.energy.2015.10.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
Solar energy has tremendous advantages including its low cost, cleanliness, and limitless supply. Specifically, the solar-hybrid heat pump system is a very safe system using the environment-friendly and harmless refrigerant R744. In this study, the analyses of the performances and exergy losses of the R22 and R744 solar-hybrid heat pump systems were carried out using experimental tests during a sunny and a cloudy day. As a result, the COP (coefficient of performance) values of the R22 and R744 heat pumps were approximately 3.21 and 2.75 during the cloudy day, respectively. On an average, these COP values increased by 20.2% compared with those elicited during the sunny day, whereas the efficiency of the solar collector decreased on average by 14.2%. In addition, the exergy loss of the solar collector during the cloudy day also increased 13.5% compared with that elicited during the sunny day. The second law efficiency of the entire R22 heat pump was 6.2% higher than that of the R744 because the irreversibility of the R744 heat pump was significantly higher and the cycle performance is very sensitive to the operating conditions compared with the subcritical cycles. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1267 / 1276
页数:10
相关论文
共 50 条
  • [31] Exergetic analysis of different R744 heat pump tumble dryer system topologies
    Brandt, Niklas
    Alpoegger, Thomas
    Tegethoff, Wilhelm
    Bockholt, Marcos
    Moehlenkamp, Andreas
    Koehler, Juergen
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [32] Comparative Study on Boiling Heat Transfer Characteristics and Performance of Low-Temperature Heating System of R744 and Its Azeotropic Refrigerant
    Sun, Dahan
    Zhang, Xin
    Liu, Zhongyan
    Zhang, Hao
    ENERGIES, 2023, 16 (03)
  • [33] Comparative analysis of the domestic hot water production with R290 and R744 heat pumps
    Masip, Ximo
    Hervas-Blasco, Estefania
    Navarro-Peris, Emilio
    Corberan, Jose M.
    14TH IIR GUSTAV-LORENTZEN CONFERENCE ON NATURAL FLUIDS, 2020, : 543 - 548
  • [34] Thermodynamic Comparative Analysis of Cascade Refrigeration System Pairing R744 with R404A, R448A and R449A with Internal Heat Exchanger: Part 2-Exergy Characteristics
    Jeon, Min-Ju
    Lee, Joon-Hyuk
    ENERGIES, 2024, 17 (18)
  • [35] Solar-assisted R22 and R134a heat pump systems for low-temperature applications
    AbouZiyan, HZ
    Ahmed, MF
    Metwally, MN
    ElHameed, HMA
    APPLIED THERMAL ENGINEERING, 1997, 17 (05) : 455 - 469
  • [36] Performance analysis of an R744 ground source heat pump system with air-cooled and water-cooled gas coolers
    Hu, Haitao
    Eikevik, Trygve Magne
    Neksa, Petter
    Hafner, Armin
    Ding, Guoliang
    Huang, Qingnan
    Ye, Jingjing
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 63 : 72 - 86
  • [37] CYCLE ANALYSIS AND HEAT-TRANSFER CHARACTERISTICS OF A HEAT-PUMP USING R22/R142B REFRIGERANT MIXTURES
    KIM, TS
    SHIN, JY
    KIM, MS
    RO, ST
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1994, 17 (06): : 391 - 399
  • [38] Recent Advances in Transcritical CO2 (R744) Heat Pump System: A Review
    Rony, Rajib Uddin
    Yang, Huojun
    Krishnan, Sumathy
    Song, Jongchul
    ENERGIES, 2019, 12 (03)
  • [40] Thermodynamic Performance Investigation of Commercial R744 Booster Refrigeration Plants Based on Advanced Exergy Analysis
    Gullo, Paride
    Hafner, Armin
    Banasiak, Krzysztof