Analysis of fiducial marker-based position verification in the external beam radiotherapy of patients with prostate cancer

被引:124
作者
van der Heide, Uutke A. [1 ]
Kotte, Alexis N. T. J. [1 ]
Dehnad, Homan [1 ]
Hofman, Pieter [1 ]
Lagenijk, Jan J. W. [1 ]
van Vupen, Marco [1 ]
机构
[1] Univ Utrecht, Dept Radiat Oncol, Ctr Med, NL-3584 CX Utrecht, Netherlands
关键词
fiducial markers; prostate; position verification;
D O I
10.1016/j.radonc.2006.11.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Evaluate the fiducial marker-based position verification in the external-beam radiotherapy of patients with prostate cancer. Methods: Four hundred and fifty-three patients with prostate cancer received an IMRT treatment combined with fiducial marker-based position verification. Portal images were taken in all 35 treatment fractions. This database was used to study the accuracy of detecting the prostate position as well as the presence of time trends and the effectiveness of commonly used off-line correction protocols. Results: The variation in inter-marker distance shows that the prostate position can be detected with an accuracy better than 0.6 mm. Significant time trends in prostate position occurred in 35%, 18% and 48% of the patients in the vertical, lateral and longitudinal directions, respectively, with 34%, 9% and 35% deviating more than 3 mm over the course of the treatment. Off-line correction protocols that estimate a deviation only in the first fractions of the treatment (shrinking action level (SAL), no action level (NAL)) are not effective in following these trends. With daily off-line position correction using an adapted SAL protocol we reduced systematic positioning errors in clinical practice to less than 0.8 mm in all directions. Conclusion: Fiducial markers are a reliable tool for prostate position verification. Time trends occur frequently. Correction procedures must take such trends into account. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:38 / 45
页数:8
相关论文
共 29 条
[1]   Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID [J].
Aubin, S ;
Beaulieu, L ;
Pouliot, S ;
Pouliot, J ;
Roy, R ;
Girouard, LM ;
Martel-Brisson, N ;
Vigneault, E ;
Laverdière, J .
MEDICAL PHYSICS, 2003, 30 (07) :1825-1832
[2]   Measurements of intrafraction motion and interfraction and intrafraction rotation of prostate by three-dimensional analysis of daily portal imaging with radiopaque markers [J].
Aubry, JF ;
Beaulieu, L ;
Girouard, LM ;
Aubin, S ;
Tremblay, D ;
Laverdière, J ;
Vigneault, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01) :30-39
[3]  
BAITER JM, 1995, INT J RADIAT ONCOL, V33, P1281
[4]   Performing daily prostate targeting with a standard V-EPID and an automated radio-opaque marker detection algorithm [J].
Beaulieu, L ;
Girouard, LM ;
Aubin, S ;
Aubry, JF ;
Brouard, L ;
Roy-Lacroix, L ;
Dumont, J ;
Tremblay, D ;
Laverdière, J ;
Vigneault, E .
RADIOTHERAPY AND ONCOLOGY, 2004, 73 (01) :61-64
[5]   High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging [J].
Bel, A ;
Vos, PH ;
Rodrigus, PTR ;
Creutzberg, CL ;
Visser, AG ;
Stroom, JC ;
Lebesque, JV .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 35 (02) :321-332
[6]   A VERIFICATION PROCEDURE TO IMPROVE PATIENT SET-UP ACCURACY USING PORTAL IMAGES [J].
BEL, A ;
VANHERK, M ;
BARTELINK, H ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (02) :253-260
[7]   On-line aSi portal imaging of implanted fiducial markers for the reduction of interfraction error during conformal radiotherapy of prostate carcinoma [J].
Chung, PWM ;
Haycocks, T ;
Brown, T ;
Cambridge, Z ;
Kelly, V ;
Alasti, H ;
Jaffray, DA ;
Catton, CN .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01) :329-334
[8]   Application of the no action level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers [J].
De Boer, HCJ ;
Van Os, MJH ;
Jansen, PP ;
Heumen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (04) :969-983
[9]   A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload [J].
De Boer, HCJ ;
Heijmen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (05) :1350-1365
[10]   Clinical feasibility study for the use of implanted gold seeds in the prostate as reliable positioning markers during megavoltage irradiation [J].
Dehnad, H ;
Nederveen, AJ ;
van der Heide, UA ;
van Moorselaar, RJA ;
Hofman, P ;
Lagendijk, JJW .
RADIOTHERAPY AND ONCOLOGY, 2003, 67 (03) :295-302