Measurement of vertical oil-in-water two-phase flow using dual-modality ERT EMF system

被引:36
作者
Faraj, Yousef [1 ]
Wang, Mi [1 ,2 ]
Jia, Jiabin [1 ]
Wang, Qiang [1 ]
Xie, Cheng-gang [3 ]
Oddie, Gary [3 ]
Primrose, Ken [4 ]
Qiu, Changhua [4 ]
机构
[1] Univ Leeds, Leeds LS2 9JT, W Yorkshire, England
[2] Southwest Petr Univ, Sate Key Lab O&G Reservoir Geol & Exploitat, Chengdu, Peoples R China
[3] Schlumberger Gould Res, Cambridge CB3 0EL, England
[4] Ind Tomog Syst Plc, Manchester M3 3JZ, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Electrical Resistance Tomography; Electromagnetic Flowmeter; Dual-modality measurement system; Two-phase flow metering; Oil-in-water flow; Vertical upward flow; ELECTROMAGNETIC FLOWMETER;
D O I
10.1016/j.flowmeasinst.2015.08.010
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Oil-in-water two-phase flows are often encountered in the upstream petroleum industry. The measurement of phase flow rates is of particular importance for managing oil production and water disposal and/or water reinjection. The complexity of oil-in-water flow structures creates a challenge to flow measurement. This paper proposes a new method of two-phase flow metering, which is based on the use of dual-modality system and multidimensional data fusion. The Electrical Resistance Tomography system (ERT) is used in combination with a commercial off-the-shelf Electromagnetic Flow meter (EMF) to measure the volumetric flow rate of each constituent phase. The water flow rate is determined from the EMF with an input of the mean oil-fraction measured by the ERT. The dispersed oil-phase flow rate is determined from the mean oil-fraction and the mean oil velocity Measured by the ERT cross-correlation velocity profiling. Experiments were carried out on a vertical upward oil-in-water pipe flow, 50 mm inner-diameter test section, at different total liquid flow rates covering the range of 8-16 m(3)/hr. The oil and water flow rate measurements obtained from the ERT and the EMF are compared to their respective references. The accuracy of these measurements is discussed and the capability of the measurement system is assessed. (C) 2015 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license.
引用
收藏
页码:255 / 261
页数:7
相关论文
共 17 条
[1]  
[Anonymous], PHILOS T R SOC LON A
[2]   USE OF THE ELECTROMAGNETIC FLOWMETER IN A 2-PHASE FLOW [J].
BERNIER, RN ;
BRENNEN, CE .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1983, 9 (03) :251-257
[3]  
Jia J., 2014, 5 INT WORKSH PROC TO
[4]   Evaluation of EIT systems and algorithms for handling full void fraction range in two-phase flow measurement [J].
Jia, Jiabin ;
Wang, Mi ;
Faraj, Yousef .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (01)
[5]   Measurement of velocity profiles in multiphase flow using a multi-electrode electromagnetic flow meter [J].
Leeungculsatien, T. ;
Lucas, G. P. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2013, 31 :86-95
[6]  
Lim KW, 1999, FLOW MEAS INSTRUM, V10, P167, DOI 10.1016/S0955-5986(98)00052-1
[7]   Row-rate measurement in two-phase flow [J].
Oddie, G ;
Pearson, JRA .
ANNUAL REVIEW OF FLUID MECHANICS, 2004, 36 :149-172
[8]   FLOW OF OIL-IN-WATER EMULSIONS THROUGH ORIFICE AND VENTURI METERS [J].
PAL, R .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1993, 32 (06) :1212-1217
[9]  
Shercliff J.A., 1962, THEORY ELECTROMAGNET
[10]   Effects of water in oil and oil in water on single-phase flowmeters [J].
Skea, AF ;
Hall, AWR .