On-site polymer-coated hollow fiber membrane microextraction and gas chromatography-mass spectrometry of polychlorinated biphenyls and polybrominated diphenyl ethers

被引:48
作者
Basheer, Chanbasha
Vetrichelvan, Muthalagu
Valiyaveettil, Suresh [1 ]
Lee, Hian Kee
机构
[1] Natl Univ Singapore, Dept Chem, Singapore 117543, Singapore
[2] Natl Univ Singapore, Singapore MIT Alliance, Singapore 117543, Singapore
关键词
on-site sampling; trace level analysis; persisting organic pollutants and microextraction;
D O I
10.1016/j.chroma.2006.11.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
\Porous polypropylene hollow fiber membrane coated with a conjugated polymer was used as an on-site sampling device for the extraction of polychlorinated biphenyls and polybrominated biphenyl ethers from coastal sea water samples. The coated hollow fiber membrane was placed in a vial containing the sample, and the target compounds extracted via manual shaking of the vials at the site of sample collection. For each extraction, two fibers were used. After extraction, the fibers with the adsorbed analytes were brought back to the laboratory for further processing. Care was taken to preserve the integrity of the analytes and to avoid contamination during transport; after extraction, the fibers were carefully removed and placed in air-tight crimper vials which were stored in an ice-box. The analytes were desorbed by solvent in the laboratory and analyses were carried out using gas chromatography/mass spectrometry. This method was highly reproducible with relative standard deviations in the range of 1-9%. Recoveries from spiked water samples ranged from 83% to 98%. Low limits of detections between 0.04 and 0.21 ng l(-1) were achieved. The extraction efficiency was compared with solid-phase microextraction. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:157 / 164
页数:8
相关论文
共 35 条
[1]  
[Anonymous], 2000, HORMONALLY ACTIVE AG
[2]   Polymer-coated hollow-fiber microextraction of estrogens in water samples with analysis by gas chromatography-mass spectrometry [J].
Basheer, C ;
Jayaraman, A ;
Kee, MK ;
Valiyaveettil, S ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1100 (02) :137-143
[3]   Development and application of polymer-coated hollow fiber membrane microextraction to the determination of organochlorine pesticides in water [J].
Basheer, C ;
Suresh, V ;
Renu, R ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :213-220
[4]   Kinetics and the on-site application of standards in a solid-phase microextration fiber [J].
Chen, Y ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2004, 76 (19) :5807-5815
[5]   Time-weighted average passive sampling with a solid-phase microextraction device [J].
Chen, Y ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2003, 75 (09) :2004-2010
[6]   Determination of brominated flame retardants, with emphasis on polybrominated diphenyl ethers (PBDEs) in environmental and human samples - a review [J].
Covaci, A ;
Voorspoels, S ;
de Boer, J .
ENVIRONMENT INTERNATIONAL, 2003, 29 (06) :735-756
[7]   Polybrominated diphenyl ethers:: Occurrence, dietary exposure, and toxicology [J].
Darnerud, PO ;
Eriksen, GS ;
Jóhannesson, T ;
Larsen, PB ;
Viluksela, M .
ENVIRONMENTAL HEALTH PERSPECTIVES, 2001, 109 :49-68
[8]  
DELAPPE BW, 1983, CAN J FISH AQUAT SCI, V40, P322
[9]  
DEWIT C, 2000, CHEMOSPHERE, V46, P583
[10]   DISTRIBUTIONS OF PESTICIDES AND ORGANIC CONTAMINANTS BETWEEN WATER AND SUSPENDED SEDIMENT, SAN-FRANCISCO BAY, CALIFORNIA [J].
DOMAGALSKI, JL ;
KUIVILA, KM .
ESTUARIES, 1993, 16 (3A) :416-426