Detection of chemical warfare agent simulants and hydrolysis products in biological samples by paper spray mass spectrometry

被引:61
|
作者
McKenna, Josiah [1 ]
Dhummakupt, Elizabeth S. [2 ]
Connell, Theresa [3 ]
Demond, Paul S. [3 ]
Miller, Dennis B. [2 ]
Nilles, J. Michael [3 ]
Manicke, Nicholas E. [1 ]
Glaros, Trevor [2 ]
机构
[1] Indiana Univ Purdue Univ Indianapolis, Dept Chem & Chem Biol, Indianapolis, IN 46202 USA
[2] US Army, BioSci Div, BioDef Branch, Edgewood Chem Biol Ctr, Aberdeen Proving Ground, MD 21010 USA
[3] Excet Inc, 6225 Brandon Ave,Suite 360, Springfield, VA 22150 USA
关键词
ELECTROSPRAY-IONIZATION; QUANTITATIVE-ANALYSIS; ELECTRIC-DISCHARGE; MS; DERIVATIZATION; SUPPRESSION; DRUGS;
D O I
10.1039/c7an00144d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Paper spray ionization coupled to a high resolution tandem mass spectrometer (a quadrupole orbitrap) was used to identify and quantitate chemical warfare agent (CWA) simulants and their hydrolysis products in blood and urine. Three CWA simulants, dimethyl methylphosphonate (DMMP), trimethyl phosphate (TMP), and diisopropyl methylphosphonate (DIMP), and their isotopically labeled standards were analyzed in human whole blood and urine. Calibration curves were generated and tested with continuing calibration verification standards. Limits of detection for these three compounds were in the low ng mL(-1) range for the direct analysis of both blood and urine samples. Five CWA hydrolysis products, ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), isobutyl methylphosphonic acid (iBuMPA), cyclohexyl methylphosphonic acid (CHMPA), and pinacolyl methylphosphonic acid (PinMPA), were also analyzed. Calibration curves were generated in both positive and negative ion modes. Limits of detection in the negative ion mode ranged from 0.36 ng mL(-1) to 1.25 ng mL(-1) in both blood and urine for the hydrolysis products. These levels were well below those found in victims of the Tokyo subway attack of 2 to 135 ng mL(-1.1) Improved stability and robustness of the paper spray technique in the negative ion mode was achieved by the addition of chlorinated solvents. These applications demonstrate that paper spray mass spectrometry (PS-MS) can be used for rapid, sample preparation-free detection of chemical warfare agents and their hydrolysis products at physiologically relevant concentrations in biological samples.
引用
收藏
页码:1442 / 1451
页数:10
相关论文
共 50 条
  • [21] Detection of Chemical Warfare Agent Simulants by UV Photoionization High-Field Asymmetric Ion Mobility Spectrometry
    Liu You-Jiang
    Chen Chi-Lai
    Zhang Le-Hua
    Zhang Xiao-Tian
    Wang Hong-Wei
    Kong De-Yi
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (09) : 1259 - 1263
  • [22] Rapidly Detection of Chemical Warfare Agent Simulants by Surface Enhanced Raman Spectroscopy
    Zhang Lin
    Wen Bao-ying
    Liu Wei-we
    Fu Wen-xiang
    Kong Jing-lin
    Li Jian-feng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2022, 42 (01) : 110 - 114
  • [23] Secondary ionization of chemical warfare agent simulants: Atmospheric pressure ion mobility time-of-flight mass spectrometry
    Steiner, WE
    Clowers, BH
    Haigh, PE
    Hill, HH
    ANALYTICAL CHEMISTRY, 2003, 75 (22) : 6068 - 6076
  • [24] A whole cell optical bioassay for the detection of chemical warfare mustard agent simulants
    Antonacci, Amina
    Lambreva, Maya D.
    Arduini, Fabiana
    Moscone, Danila
    Palleschi, Giuseppe
    Scognamiglio, Viviana
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 257 : 658 - 665
  • [25] Heating paper spray mass spectrometry for enhanced detection of propranolol in dried blood samples
    Huang, Huang
    Wu, Qicai
    Zeng, Liang
    Wan, Li
    Lai, Songqing
    Yin, Xiujie
    Huang, Jianfeng
    Yang, Bicheng
    Liu, Jichun
    ANALYTICAL METHODS, 2017, 9 (29) : 4282 - 4287
  • [26] Rapid Detection of Chemical Warfare Agent Simulants Using Gold Nanoparticles Substrate-assisted Enhanced Low Temperature Plasma-Mass Spectrometry
    Zhang, Lin
    Ma, Ming-Ying
    Li, Bao-Qiang
    Kong, Jing-Lin
    Zhang, Si-Chun
    Zhang, Xin-Rong
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (10) : 1416 - 1421
  • [27] MALDI-TOF Mass Spectrometric Analysis of Chemical Warfare Nerve Agent Simulants
    Kim, Eunhee
    Lee, Hyunji
    Choi, Sun-Kyung
    Yoon, Myung-Han
    Oh, Han Bin
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2016, 37 (03): : 316 - 320
  • [28] On-substrate derivatization for detection of highly volatile G-series chemical warfare agents via paper spray mass spectrometry
    Mach, Phillip M.
    Dhummakupt, Elizabeth S.
    Carmany, Daniel O.
    McBride, Ethan M.
    Busch, Michael W.
    Demond, Paul S.
    Rizzo, Gabrielle M.
    Hollinshead, Donna E.
    Glaros, Trevor
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (23) : 1979 - 1983
  • [29] Terahertz electronics for chemical and biological warfare agent detection
    Woolard, D
    Kaul, R
    Suenram, R
    Walker, AH
    Globus, T
    Samuels, A
    1999 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-4, 1999, : 925 - 928
  • [30] Detection of chemical warfare agent degradation products in foods using liquid chromatography coupled to inductively coupled plasma mass spectrometry and electrospray ionization mass spectrometry
    Kubachka, Kevin M.
    Richardson, Douglas D.
    Heitkemper, Douglas T.
    Caruso, Joseph A.
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (02) : 124 - 131