Detection of chemical warfare agent simulants and hydrolysis products in biological samples by paper spray mass spectrometry

被引:61
|
作者
McKenna, Josiah [1 ]
Dhummakupt, Elizabeth S. [2 ]
Connell, Theresa [3 ]
Demond, Paul S. [3 ]
Miller, Dennis B. [2 ]
Nilles, J. Michael [3 ]
Manicke, Nicholas E. [1 ]
Glaros, Trevor [2 ]
机构
[1] Indiana Univ Purdue Univ Indianapolis, Dept Chem & Chem Biol, Indianapolis, IN 46202 USA
[2] US Army, BioSci Div, BioDef Branch, Edgewood Chem Biol Ctr, Aberdeen Proving Ground, MD 21010 USA
[3] Excet Inc, 6225 Brandon Ave,Suite 360, Springfield, VA 22150 USA
关键词
ELECTROSPRAY-IONIZATION; QUANTITATIVE-ANALYSIS; ELECTRIC-DISCHARGE; MS; DERIVATIZATION; SUPPRESSION; DRUGS;
D O I
10.1039/c7an00144d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Paper spray ionization coupled to a high resolution tandem mass spectrometer (a quadrupole orbitrap) was used to identify and quantitate chemical warfare agent (CWA) simulants and their hydrolysis products in blood and urine. Three CWA simulants, dimethyl methylphosphonate (DMMP), trimethyl phosphate (TMP), and diisopropyl methylphosphonate (DIMP), and their isotopically labeled standards were analyzed in human whole blood and urine. Calibration curves were generated and tested with continuing calibration verification standards. Limits of detection for these three compounds were in the low ng mL(-1) range for the direct analysis of both blood and urine samples. Five CWA hydrolysis products, ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), isobutyl methylphosphonic acid (iBuMPA), cyclohexyl methylphosphonic acid (CHMPA), and pinacolyl methylphosphonic acid (PinMPA), were also analyzed. Calibration curves were generated in both positive and negative ion modes. Limits of detection in the negative ion mode ranged from 0.36 ng mL(-1) to 1.25 ng mL(-1) in both blood and urine for the hydrolysis products. These levels were well below those found in victims of the Tokyo subway attack of 2 to 135 ng mL(-1.1) Improved stability and robustness of the paper spray technique in the negative ion mode was achieved by the addition of chlorinated solvents. These applications demonstrate that paper spray mass spectrometry (PS-MS) can be used for rapid, sample preparation-free detection of chemical warfare agents and their hydrolysis products at physiologically relevant concentrations in biological samples.
引用
收藏
页码:1442 / 1451
页数:10
相关论文
共 50 条
  • [11] Detection of Protein Toxin Simulants from Contaminated Surfaces by Paper Spray Mass Spectrometry
    Wichert, William R. A.
    Dhummakupt, Elizabeth S.
    Zhang, Chengsen
    Mach, Phillip M.
    Bernhards, Robert C.
    Glaros, Trevor
    Manicke, Nicholas E.
    Journal of the American Society for Mass Spectrometry, 2019, 30 (08): : 1406 - 1415
  • [12] Detection of Protein Toxin Simulants from Contaminated Surfaces by Paper Spray Mass Spectrometry
    Wichert, William R. A.
    Dhummakupt, Elizabeth S.
    Zhang, Chengsen
    Mach, Phillip M.
    Bernhards, Robert C.
    Glaros, Trevor
    Manicke, Nicholas E.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2019, 30 (08) : 1406 - 1415
  • [13] Structural Effect of Thioureas on the Detection of Chemical Warfare Agent Simulants
    Ha, Seonggyun
    Lee, Minhe
    Seo, Hyun Ook
    Song, Sun Gu
    Kim, Kyung-su
    Park, Chan Heum
    Kim, Il Hee
    Kim, Young Dok
    Song, Changsik
    ACS SENSORS, 2017, 2 (08): : 1146 - 1151
  • [14] Gold nanoparticles-enhanced ion-transmission mass spectrometry for highly sensitive detection of chemical warfare agent simulants
    Zhang, Lin
    Zhao, Xu
    Cheng, Huiyun
    Kong, Jinglin
    Zhao, Yaoyao
    Zhu, Xuewei
    Zhang, Sichun
    Zhang, Xinrong
    TALANTA, 2018, 190 : 403 - 409
  • [15] Direct detection of chemical warfare agent simulants in soil by thermal desorption-low temperature plasma-mass spectrometry
    Li, Baoqiang
    Kong, Jinglin
    Yang, Liu
    Zhang, Lin
    Zhang, Zhongyao
    Li, Cuiping
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2020, 451
  • [16] Paper spray mass spectrometry applied to the detection of cocaine in simulated samples
    Almeida de Paula, Camila Cristina
    Lordeiro, Rogerio Araujo
    Piccin, Evandro
    Augusti, Rodinei
    ANALYTICAL METHODS, 2015, 7 (21) : 9145 - 9149
  • [17] Detection of simulants and degradation products of Chemical Warfare Agents by vibrational spectroscopy
    Ruiz-Pesante, Orlando
    Pacheco-Londono, Leonardo C.
    Primera-Pedrozo, Oliva M.
    Ortiz, William
    Soto-Feliciano, Yadira M.
    Nieves, Deborah E.
    Ramirez, Michael L.
    Hernandez-Rivera, Samuel P.
    CHEMICAL AND BIOLOGICAL SENSING VIII, 2007, 6554
  • [18] Coordination-cage binding and catalysed hydrolysis of organophosphorus chemical warfare agent simulants
    Sudittapong, Burin
    Taylor, Christopher G. P.
    Williams, James
    Griffiths, Rebecca J.
    Hiscock, Jennifer R.
    Ward, Michael D.
    RSC ADVANCES, 2024, 14 (36) : 26032 - 26042
  • [19] Infrared signatures of thermal degradation products from chemical warfare agent simulants
    Gese, Natalie
    Eilers, Hergen
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES, CBRNE SENSING XXV, 2024, 13056
  • [20] Analysis of gaseous toxic industrial compounds and chemical warfare agent simulants by atmospheric pressure ionization mass spectrometry
    Cotte-Rodríguez, I
    Justes, DR
    Nanita, SC
    Noll, RJ
    Mulligan, CC
    Sanders, NL
    Cooks, RG
    ANALYST, 2006, 131 (04) : 579 - 589