Comparison of in-source collision-induced dissociation and beam-type collision-induced dissociation of emerging synthetic drugs using a high-resolution quadrupole time-of-flight mass spectrometer

被引:17
作者
Davidson, J. Tyler [1 ,3 ]
Sasiene, Zachary J. [2 ]
Jackson, Glen P. [1 ,2 ]
机构
[1] West Virginia Univ, Dept Forens & Invest Sci, Morgantown, WV 26506 USA
[2] West Virginia Univ, C Eugene Bennett Dept Chem, Morgantown, WV 26506 USA
[3] Sam Houston State Univ, Dept Forens Sci, Huntsville, TX 77340 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2021年 / 56卷 / 02期
关键词
forensic science; in‐ source CID; novel psychoactive substances; seized drugs; tandem mass spectrometry;
D O I
10.1002/jms.4679
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In-source collision-induced dissociation (CID) is commonly used with single-stage high-resolution mass spectrometers to gather both a molecular formula and structural information through the collisional activation of analytes with residual background gas in the source region of the mass spectrometer. However, unlike tandem mass spectrometry, in-source CID does not involve an isolation step prior to collisional activation leading to a product ion spectrum composed of fragment ions from any analyte present during the activation event. This work provides the first comparison of in-source CID and beam-type CID spectra of emerging synthetic drugs on the same instrument to understand the fragmentation differences between the two techniques and to contribute to the scientific foundations of in-source CID. Electrospray ionization-quadrupole time-of-flight (ESI-Q-TOF) mass spectrometry was used to generate product ion spectra from in-source CID and beam-type CID for a series of well-characterized fentanyl analogs and synthetic cathinones. A comparison between the fragmentation patterns and relative ion abundances for each technique was performed over a range of fragmentor offset voltages for in-source CID and a range of collision energies for beam-type CID. The results indicate that large fragmentor potentials for in-source CID tend to favor higher energy fragmentation pathways that result in both kinetically favored pathways and consecutive neutral losses, both of which produce more abundant lower mass product ions relative to beam-type CID. Although conditions can be found in which in-source CID and beam-type CID provide similar overall spectra, the in-source CID spectra tend to contain elevated noise and additional chemical background peaks relative to beam-type CID.
引用
收藏
页数:15
相关论文
共 80 条
[1]   In-source fragmentation and accurate mass analysis of multiclass flavonoid conjugates by electrospray ionization time-of-flight mass spectrometry [J].
Abranko, Laszlo ;
Garcia-Reyes, Juan F. ;
Molina-Diaz, Antonio .
JOURNAL OF MASS SPECTROMETRY, 2011, 46 (05) :478-488
[2]   Fragmentation pathways of drugs of abuse and their metabolites based on QTOF MS/MS and MSE accurate-mass spectra [J].
Bijlsma, Lubertus ;
Sancho, Juan V. ;
Hernandez, Felix ;
Niessen, Wilfried M. A. .
JOURNAL OF MASS SPECTROMETRY, 2011, 46 (09) :865-875
[3]   Poor reproducibility of in-source collisional atmospheric pressure ionization mass spectra of toxicologically relevant drugs [J].
Bogusz, MJ ;
Maier, RD ;
Krüger, KD ;
Webb, KS ;
Romeril, J ;
Miller, ML .
JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) :409-418
[4]   Evaluation of protocols for reproducible electrospray in-source collisionally induced dissociation on various liquid chromatography/mass spectrometry instruments and the development of spectral libraries [J].
Bristow, AWT ;
Nichols, WF ;
Webb, KS ;
Conway, B .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (24) :2374-2386
[5]   Direct Analysis in Real Time (DART) and a portable mass spectrometer for rapid identification of common and designer drugs on-site [J].
Brown, Hilary ;
Oktem, Berk ;
Windom, Ashley ;
Doroshenko, Vladimir ;
Evans-Nguyen, Kenyon .
FORENSIC CHEMISTRY, 2016, 1 :66-73
[6]   Comparison of dissociation of ions in an electrospray source, or a collision cell in tandem mass spectrometry [J].
Buré, C ;
Lange, C .
CURRENT ORGANIC CHEMISTRY, 2003, 7 (15) :1613-1624
[7]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[8]  
Collette C, 1998, RAPID COMMUN MASS SP, V12, P1673, DOI 10.1002/(SICI)1097-0231(19981130)12:22<1673::AID-RCM385>3.0.CO
[9]  
2-A
[10]  
Collette C, 1998, RAPID COMMUN MASS SP, V12, P165, DOI 10.1002/(SICI)1097-0231(19980227)12:4<165::AID-RCM140>3.0.CO