Allergic contact dermatitis from a disposable blood pressure cuff containing isobornyl acrylate and 2-phenoxyethyl acrylate

被引:13
作者
Renaudin, Helene [1 ]
Darrigade, Anne-Sophie [1 ]
Dendooven, Ella [2 ,3 ,4 ]
Foubert, Kenn [4 ]
Aerts, Olivier [2 ,3 ]
Milpied, Brigitte [1 ]
机构
[1] CHU Bordeaux, Dept Dermatol, Hop St Andre, Bordeaux, France
[2] Univ Antwerp, Univ Antwerp Hosp, Dept Dermatol, Antwerp, Belgium
[3] Univ Antwerp, Res Grp Immunol, Infla Med Ctr Excellence, Antwerp, Belgium
[4] Univ Antwerp, Dept Pharmaceut Sci, Res Grp Nat Prod & Food Res & Anal NatuRA, Antwerp, Belgium
关键词
2-phenoxyethyl acrylate; allergic contact dermatitis; case report; children; diabetes mellitus; disposable blood pressure cuff; FreeStyle Libre; isobornyl acrylate; lauryl acrylate; medical devices; LIBRE; GLUE;
D O I
10.1111/cod.13761
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
[No abstract available]
引用
收藏
页码:462 / 464
页数:3
相关论文
共 10 条
[1]   Isobornyl Acrylate [J].
Aerts, Olivier ;
Herman, Anne ;
Mowitz, Martin ;
Bruze, Magnus ;
Goossens, An .
DERMATITIS, 2020, 31 (01) :4-12
[2]   CONTACT ALLERGY TO COMPONENTS OF GLUE IN INSULIN PUMP INFUSION SETS [J].
BUSSCHOTS, AM ;
MEULEMAN, V ;
POESEN, N ;
DOOMSGOOSSENS, A .
CONTACT DERMATITIS, 1995, 33 (03) :205-206
[3]   Concomitant positive patch test reactions in FreeStyle-allergic patients sensitized to isobornyl acrylate [J].
Dendooven, Ella ;
Foubert, Kenn ;
Goossens, An ;
Gilles, Philippe ;
De Borggraeve, Wim ;
Pieters, Luc ;
Lambert, Julien ;
Aerts, Olivier .
CONTACT DERMATITIS, 2021, 84 (03) :166-174
[4]   Unexpected positive patch test reactions to sesquiterpene lactones in patients sensitized to the glucose sensor FreeStyle Libre [J].
Herman, Anne ;
Mowitz, Martin ;
Aerts, Olivier ;
Pyl, Jeroen ;
de Montjoye, Laurence ;
Goossens, An ;
Bruze, Magnus ;
Baeck, Marie .
CONTACT DERMATITIS, 2019, 81 (05) :354-367
[5]   Allergic contact dermatitis caused by isobornyl acrylate in Freestyle® Libre, a newly introduced glucose sensor [J].
Herman, Anne ;
Aerts, Olivier ;
Baeck, Marie ;
Bruze, Magnus ;
De Block, Christophe ;
Goossens, An ;
Hamnerius, Nils ;
Huygens, Sara ;
Maiter, Dominique ;
Tennstedt, Dominique ;
Vandeleene, Bernard ;
Mowitz, Martin .
CONTACT DERMATITIS, 2017, 77 (06) :367-373
[6]   European Society of Contact Dermatitis guideline for diagnostic patch testing - recommendations on best practice [J].
Johansen, Jeanne D. ;
Aalto-Korte, Kristiina ;
Agner, Tove ;
Andersen, Klaus E. ;
Bircher, Andreas ;
Bruze, Magnus ;
Cannavo, Alicia ;
Gimenez-Arnau, Ana ;
Goncalo, Margarida ;
Goossens, An ;
John, Swen M. ;
Liden, Carola ;
Lindberg, Magnus ;
Mahler, Vera ;
Matura, Mihly ;
Rustemeyer, Thomas ;
Serup, Jorgen ;
Spiewak, Radoslaw ;
Thyssen, Jacob P. ;
Vigan, Martine ;
White, Ian R. ;
Wilkinson, Mark ;
Uter, Wolfgang .
CONTACT DERMATITIS, 2015, 73 (04) :195-221
[7]   Allergic contact dermatitis from phenoxyethoxy ethylacrylates in optical fiber coating, and glue in an insulin pump set [J].
Jolanki, R ;
Kanerva, L ;
Estlander, T ;
Henriks-Eckerman, ML ;
Suhonen, R .
CONTACT DERMATITIS, 2001, 45 (01) :36-37
[8]   The Dexcom glucose monitoring system-An isobornyl acrylate-free alternative for diabetic patients [J].
Oppel, Eva ;
Kamann, Stefanie ;
Reichl, Franz-Xaver ;
Hoegg, Christof .
CONTACT DERMATITIS, 2019, 81 (01) :32-36
[9]   Prevalence and Prevention of Contact Dermatitis Caused by FreeStyle Libre: A Monocentric Experience [J].
Pyl, Jeroen ;
Dendooven, Ella ;
Van Eekelen, Ine ;
den Brinker, Marieke ;
Dotremont, Hilde ;
France, Annick ;
Foubert, Kenn ;
Pieters, Luc ;
Lambert, Julien ;
De Block, Christophe ;
Aerts, Olivier .
DIABETES CARE, 2020, 43 (04) :918-920
[10]  
Svedman C, 2020, J EUR ACAD DERMATOL