Development of proficiency testing for detection of bacterial contamination of platelet products

被引:6
作者
Easley, Samantha
Yomtovian, Roslyn A.
Sullivan, Patricia
Jacobs, Michael R.
机构
[1] Case Western Reserve Univ, Dept Pathol, Cleveland, OH 44106 USA
[2] Univ Hosp Cleveland, Cleveland, OH 44106 USA
关键词
D O I
10.1111/j.1537-2995.2007.01096.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Accrediting agencies now require quality control for minimizing platelet (PLT) bacterial contamination (PBC). A proficiency testing (PT) strategy for PBC testing was developed. Study Design and Methods: During Phase 1, validation of the pH meter and an enhanced bacteria detection system (Pall eBDS)-methods used in our blood bank-was accomplished with two aliquots of an apheresis PLT unit inoculated with Escherichia coli (ATCC 25922, 70 CFU/mL) or Staphylococcus aureus (ATCC 27217, 46 CFU/mL) with an uninoculated aliquot serving as a negative control. Quantitative plate culture was the reference method. PLTs were stored on a rotator at 22 degrees C. Units were sampled in duplicate at 0, 24, and 48 hours. pH testing was considered positive when the pH value was less than 6.6. eBDS was positive when the oxygen concentration was less than 9.4 percent. During Phase 2, synchronized PT of pH and eBDS was performed at four independent sites. PLT samples were inoculated and incubated as above, and aliquots were removed at Time 0 for eBDS testing and at 48 hours for pH testing. Results: In Phase 1, on inoculated bags eBDS was positive at all time periods but pH was positive only at 48 hours. In Phase 2, synchronized results showed positive eBDS at Time 0 and positive pH at 48 hours on inoculated bags with agreement between paired sites. Conclusions: This strategy may serve as a useful model for developing PT materials for PBC detection. eBDS was able to identify low levels of PBC, and pH testing, only much higher levels. It is important to carefully coordinate and standardize handling of PT materials and reporting of results.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 16 条
[1]  
*AM ASS BLOOD BANK, 2003, AM ASS BLOOD BANKS A, V312
[2]  
[Anonymous], 2004, STANDARDS BLOOD BANK
[3]   Bacterial contamination of blood components [J].
Brecher, ME ;
Hay, SN .
CLINICAL MICROBIOLOGY REVIEWS, 2005, 18 (01) :195-+
[4]  
Burns KH, 2004, ARCH PATHOL LAB MED, V128, P279
[5]  
*CLSI, 2002, GP29A CLSI NCCLS
[6]   Detection of bacterial contamination in apheresis platelet products: American Red Cross experience, 2004 [J].
Fang, CT ;
Chambers, LA ;
Kennedy, J ;
Strupp, A ;
Fucci, MCH ;
Janas, JA ;
Tang, YL ;
Hapip, CA ;
Lawrence, TB ;
Dodd, RY .
TRANSFUSION, 2005, 45 (12) :1845-1852
[7]  
*FDA ADV COMM BLOO, 2005, CURR STAT BACT DET P
[8]  
Hillyer Christopher D, 2003, Hematology Am Soc Hematol Educ Program, P575
[9]   Enhancement of a culture-based bacterial detection system (eBDS) for platelet products based on measurement of oxygen consumption [J].
Holme, S ;
McAlister, MB ;
Ortolano, GA ;
Chong, C ;
Cortus, MA ;
Jacobs, MR ;
Yomtovian, R ;
Freundlich, LF ;
Wenz, B .
TRANSFUSION, 2005, 45 (06) :984-993
[10]   Estimation of bacterial risk in extending the shelf life of PLT concentrates from 5 to 7 days [J].
Lee, CK ;
Ho, PL ;
Lee, KY ;
Cheng, WW ;
Chan, NK ;
Tsoi, WC ;
Lin, CK .
TRANSFUSION, 2003, 43 (08) :1047-1052