Two- and Three-Dimensional Profilometer Assessments to Determine Titanium Roughness

被引:15
作者
Canabarro, A. [1 ]
Figueiredo, F. [1 ]
Paciornik, S. [2 ]
De-Deus, G. [3 ]
机构
[1] Univ Veiga de Almeida, Dept Periodontol, Rio De Janeiro, Brazil
[2] Pontificia Univ Catolica Rio de Janeiro, Dept Mat Sci & Met, Rio De Janeiro, Brazil
[3] Univ Veiga de Almeida, Dept Endodont, Rio De Janeiro, Brazil
关键词
titanium; dental implants; titanium surface; surface roughness; surface topography; SCREW-SHAPED IMPLANTS; HISTOMORPHOMETRIC ANALYSIS; SURFACE TREATMENTS; BONE INTEGRATION; TOPOGRAPHY;
D O I
10.1002/sca.20156
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this study, a comparative topography analysis of titanium (Ti) surfaces was performed using two- (2D) and three-dimensional (3D) profilometers. Ti samples were either only sandblasted (SB) using Al(2)O(3) particles or were SB and received an additional chemical treatment using a solution of 4% HF (SLA). Samples with no treatment were used as a control group (C). Therefore, three different surfaces were evaluated: SB, SLA and C. The Ti surface topographies were evaluated by scanning electron microscopy. An Ra roughness measurement was performed on each Ti sample by 2D and 3D profilometers. Surface roughness was also characterized using amplitude, spatial and hybrid 3D parameters. 2D and 3D profilometer analyses produced very close results. Mean Ra values range from 0.19 to 0.25 (C, p<0.05), 0.84 to 0.99 (SLA, p<0.05) and 0.98 to 1 mu m (SB, p>0.05). The statistically different Ra values depending on the surface studied may be explained by methodological and technical differences. Also, 3D profilometer seems to be the more appropriate analytical method for measuring the roughness of Ti surfaces because it also describes surface organization. SCANNING 31: 174-179, 2009. (c) 2009 Wiley Periodicals, Inc.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 22 条
  • [1] Al-Nawas B, 2001, SCANNING, V23, P227, DOI 10.1002/sca.4950230401
  • [2] OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN
    ALBREKTSSON, T
    BRANEMARK, PI
    HANSSON, HA
    LINDSTROM, J
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02): : 155 - 170
  • [3] Topography effects of pure titanium substrates on human osteoblast long-term adhesion
    Anselme, K
    Bigerelle, M
    [J]. ACTA BIOMATERIALIA, 2005, 1 (02) : 211 - 222
  • [4] Improvement in the morphology of Ti-based surfaces:: a new process to increase in vitro human osteoblast response
    Bigerelle, M
    Anselme, K
    Noël, B
    Ruderman, I
    Hardouin, P
    Iost, A
    [J]. BIOMATERIALS, 2002, 23 (07) : 1563 - 1577
  • [5] INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS
    BUSER, D
    SCHENK, RK
    STEINEMANN, S
    FIORELLINI, JP
    FOX, CH
    STICH, H
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07): : 889 - 902
  • [6] High concentration of residual aluminum oxide on titanium surface inhibits extracellular matrix mineralization
    Canabarro, A.
    Diniz, M. G.
    Paciornik, S.
    Carvalho, L.
    Sampaio, E. M.
    Beloti, M. M.
    Rosa, A. L.
    Fischer, R. G.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 87A (03) : 588 - 597
  • [7] Carlsson L, 1988, Int J Oral Maxillofac Implants, V3, P21
  • [8] Influence of different implant surfaces on peri-implant osteogenesis: Histomorphometric analysis in sheep
    Franchi, Marco
    Bacchelli, Beatrice
    Giavaresi, Gianluca
    De Pasquale, Viviana
    Martini, Desiree
    Fini, Milena
    Giardino, Roberto
    Ruggeri, Alessandro
    [J]. JOURNAL OF PERIODONTOLOGY, 2007, 78 (05) : 879 - 888
  • [9] Gotfredsen K, 1992, Clin Oral Implants Res, V3, P77, DOI 10.1034/j.1600-0501.1992.030205.x
  • [10] Histologic evaluation of the bone integration of TiO2 blasted and turned titanium microimplants in humans
    Ivanoff, CJ
    Hallgren, C
    Widmark, G
    Sennerby, L
    Wennerberg, A
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (02) : 128 - 134