Stability of the Baseline Holder in Readout Circuits for Radiation Detectors

被引:3
作者
Chen, Y. [1 ,2 ,3 ]
Cui, Y. [1 ]
O'Connor, P. [1 ]
Seo, Y. [4 ]
Camarda, G. S. [1 ]
Hossain, A. [1 ]
Roy, U. [1 ]
Yang, G. [1 ]
James, R. B. [1 ]
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Minist Educ, Key Lab Particle & Radiat Imaging, Beijing 100084, Peoples R China
[4] Univ Calif San Francisco, San Francisco, CA 94143 USA
基金
美国国家卫生研究院;
关键词
ASIC; baseline holder; large-signal analyses; stability; transient-noise analyses;
D O I
10.1109/TNS.2016.2516007
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Baseline holder (BLH) circuits are used widely to stabilize the analog output of application-specific integrated circuits (ASICs) for high-count-rate applications. The careful design of BLH circuits is vital to the overall stability of the analog-signal-processing chain in ASICs. Recently, we observed self-triggered fluctuations in an ASIC in which the shaping circuits have a BLH circuit in the feedback loop. In fact, further investigations showed that methods of enhancing small-signal stabilities cause an even worse situation. To resolve this problem, we used large-signal analyses to study the circuit's stability. We found that a relatively small gain for the error amplifier and a small current in the non-linear stage of the BLH are required to enhance stability in large-signal analysis, which will compromise the properties of the BLH. These findings were verified by SPICE simulations. In this paper, we present our detailed analysis of the BLH circuits, and propose an improved version of them that have only minimal self-triggered fluctuations. We summarize the design considerations both for the stability and the properties of the BLH circuits.
引用
收藏
页码:316 / 324
页数:9
相关论文
共 16 条
[1]  
Allen PhillipE., 2002, CMOS ANALOG CIRCUIT, V2nd
[2]  
[Anonymous], 2014, SMARTSPICE US MAN
[3]  
Bombelli L, 2011, IEEE NUCL SCI CONF R, P944, DOI 10.1109/NSSMIC.2011.6154300
[4]  
Celani A, 2010, IEEE NUCL SCI CONF R, P1382, DOI 10.1109/NSSMIC.2010.5873997
[5]  
Chiosso M., 2008, 2008 IEEE Nuclear Science Symposium Conference Record, P1495, DOI DOI 10.1109/NSSMIC.2008.4774697
[6]  
Corsi F., 2008, 2008 15th IEEE International Conference on Electronics, Circuits and Systems (ICECS 2008), P690, DOI 10.1109/ICECS.2008.4674947
[7]   MOSFET optimization in deep submicron technology for charge amplifiers [J].
De Geronimo, G ;
O'Connor, P .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (06) :3223-3232
[8]   A CMOS baseline holder (BLH) for readout ASICs [J].
De Geronimo, G ;
O'Connor, P ;
Grosholz, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) :818-822
[9]   ASIC with multiple energy discrimination for high-rate photon counting applications [J].
De Geronimo, Gianluigi ;
Dragone, Angelo ;
Grosholz, Joe ;
O'Connor, Paul ;
Vernon, Emerson .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (02) :303-312
[10]   Study of a high-resolution, 3D positioning cadmium zinc telluride detector for PET [J].
Gu, Y. ;
Matteson, J. L. ;
Skelton, R. T. ;
Deal, A. C. ;
Stephan, E. A. ;
Duttweiler, F. ;
Gasaway, T. M. ;
Levin, C. S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (06) :1563-1584