3D measurements in conventional X-ray imaging with RGB-D sensors

被引:3
作者
Albiol, Francisco [1 ]
Corbi, Alberto [1 ]
Albiol, Alberto [2 ]
机构
[1] Univ Valencia, CSIC, Inst Fis Corpuscular, E-46003 Valencia, Spain
[2] Univ Politecn Valencia, Inst Telecomunicac Aplicac Multimedia iTeam, E-46022 Valencia, Spain
关键词
X-ray; Depth cameras; Epipolar geometry; 3D reconstruction; Movement tracking; Dense surface mapping; MICROSOFT KINECT; CALIBRATION;
D O I
10.1016/j.medengphy.2017.01.024
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A method for deriving 3D internal information in conventional X-ray settings is presented. It is based on the combination of a pair of radiographs from a patient and it avoids the use of X-ray-opaque fiducials and external reference structures. To achieve this goal, we augment an ordinary X-ray device with a consumer RGB-D camera. The patient' s rotation around the craniocaudal axis is tracked relative to this camera thanks to the depth information provided and the application of a modern surface-mapping algorithm. The measured spatial information is then translated to the reference frame of the X-ray imaging system. By using the intrinsic parameters of the diagnostic equipment, epipolar geometry, and X-ray images of the patient at different angles, 3D internal positions can be obtained. Both the RGB-D and Xray instruments are first geometrically calibrated to find their joint spatial transformation. The proposed method is applied to three rotating phantoms. The first two consist of an anthropomorphic head and a torso, which are filled with spherical lead bearings at precise locations. The third one is made of simple foam and has metal needles of several known lengths embedded in it. The results show that it is possible to resolve anatomical positions and lengths with a millimetric level of precision. With the proposed approach, internal 3D reconstructed coordinates and distances can be provided to the physician. It also contributes to reducing the invasiveness of ordinary X-ray environments and can replace other types of clinical explorations that are mainly aimed at measuring or geometrically relating elements that are present inside the patient's body.(C) 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 23 条
  • [1] Geometrical Calibration of X-Ray Imaging With RGB Cameras for 3D Reconstruction
    Albiol, Francisco
    Corbi, Alberto
    Albiol, Alberto
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2016, 35 (08) : 1952 - 1961
  • [2] [Anonymous], 1998, Statistical shape analysis
  • [3] [Anonymous], 2011, P 5 IEEE INT C AUTOM
  • [4] [Anonymous], 2001, Robotica, DOI DOI 10.1017/S0263574700223217
  • [5] [Anonymous], P WORKSH COL DEPTH C
  • [6] Aoki M, 2013, P WORLD C MED PHYS B, P1456
  • [7] Badal A, 2013, P PHYS MED IMAGING S, P8668
  • [8] Bauer S., 2011, 2011 IEEE International Conference on Computer Vision Workshops (ICCV Workshops), P1175, DOI 10.1109/ICCVW.2011.6130383
  • [9] A METHOD FOR REGISTRATION OF 3-D SHAPES
    BESL, PJ
    MCKAY, ND
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) : 239 - 256
  • [10] Caponetti L, 1990, P 12 ANN INT C IEEE, P208