Multimodal Assessment of the Aortic Annulus Diameter Implications for Transcatheter Aortic Valve Implantation

被引:330
作者
Messika-Zeitoun, David [1 ,2 ]
Serfaty, Jean-Michel [3 ]
Brochet, Eric [1 ]
Ducrocq, Gregory [1 ]
Lepage, Laurent [1 ]
Detaint, Delphine [1 ]
Hyafil, Fabien [1 ]
Himbert, Dominique [1 ]
Pasi, Nicoletta [3 ]
Laissy, Jean-Pierre [3 ]
Iung, Bernard [1 ]
Vahanian, Alec [1 ]
机构
[1] Hop Xavier Bichat, AP HP, Dept Cardiol, F-75018 Paris, France
[2] Univ Paris 07, INSERM, U698, Paris, France
[3] Hop Xavier Bichat, AP HP, Dept Radiol, F-75018 Paris, France
关键词
aortic stenosis; transthoracic echocardiography; transesophageal echocardiography; multislice computed tomography; transcatheter aortic valve implantation; MULTISLICE COMPUTED-TOMOGRAPHY; VALVULAR HEART-DISEASE; EUROPEAN-SOCIETY; STENOSIS; ECHOCARDIOGRAPHY; RECOMMENDATIONS; REPLACEMENT; PROSTHESIS; MANAGEMENT; ACCURACY;
D O I
10.1016/j.jacc.2009.06.063
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We sought to compare 3 methods of measurements of the aortic annulus, transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and multislice computed tomography (MSCT), and to evaluate their potential clinical impact on transcatheter aortic valve implantation (TAVI) strategy. Background Exact measurement of the aortic annulus is critical for a patient's selection and successful implantation. Methods Annulus diameter was measured using TTE, TEE, and MSCT in 45 consecutive patients with severe aortic stenosis referred for TAVI. The TAVI strategy (decision to implant and choice of the prosthesis' size) was based on manufacturer's recommendations (Edwards-Sapien prosthesis, Edwards Lifesciences, Inc., Irvine, California). Results Correlations between methods were good but the difference between MSCT and TTE (1.22 +/- 1.3 mm) or TEE (1.52 +/- 1.1 mm) was larger than the difference between TTE and TEE (0.6 +/- 0.8 mm; p = 0.03 and p < 0.0001, respectively). Regarding TAVI strategy, agreement between TTE and TEE overall was good (kappa = 0.68), but TAVI strategy would have been different in 8 patients (17%). Agreement between MSCT and TTE or TEE was only modest (kappa = 0.28 and 0.27), and a decision based on MSCT measurements would have modified the TAVI strategy in a large number of patients (40% to 42%). Implantation, performed in 34 patients (76%) based on TEE measurements, was successful in all but 1 patient with grade 3/4 regurgitation. Conclusions In patients referred for TAVI, measurements of the aortic annulus using TTE, TEE, and MSCT were close but not identical, and the method used has important potential clinical implications on TAVI strategy. In the absence of a gold standard, a strategy based on TEE measurements provided good clinical results. (J Am Coll Cardiol 2010; 55: 186-94) (C) 2010 by the American College of Cardiology Foundation
引用
收藏
页码:186 / 194
页数:9
相关论文
共 31 条
[1]   Aortic root morphology in patients undergoing percutaneous aortic valve replacement: Evidence of aortic root remodeling [J].
Akhtar, Mateen ;
Tuzcu, E. Murat ;
Kapadia, Samir R. ;
Svensson, Lars G. ;
Greenberg, Roy K. ;
Roselli, Eric E. ;
Halliburton, Sandra ;
Kurra, Vikram ;
Schoenhagen, Paul ;
Sola, Srikanth .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (04) :950-956
[2]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[3]  
American College of Cardiology, 2006, J Am Coll Cardiol, V48, pe1, DOI 10.1016/j.jacc.2006.05.021
[4]   Can Balloon Aortic Valvuloplasty Help Determine Appropriate Transcatheter Aortic Valve Size? [J].
Babaliaros, Vasilis C. ;
Liff, David ;
Chen, Edward P. ;
Rogers, Jason H. ;
Brown, Ryan A. ;
Thourani, Vinod H. ;
Guyton, Robert A. ;
Lerakis, Stamatios ;
Stillman, Arthur E. ;
Raggi, Paolo ;
Cheesborough, Jennifer E. ;
Veladar, Emir ;
Green, Jacob T. ;
Block, Peter C. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (05) :580-586
[5]   Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice [J].
Baumgartner, Helmut ;
Hung, Judy ;
Bermejo, Javier ;
Chambers, John B. ;
Evangelista, Arturo ;
Griffin, Brian P. ;
Iung, Bernard ;
Otto, Catherine M. ;
Pellikka, Patricia A. ;
Quinones, Miguel .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01) :1-25
[6]   Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography [J].
Bouvier, Erik ;
Logeart, Damien ;
Sablayrolles, Jean-Louis ;
Feignoux, Jacques ;
Scheuble, Claude ;
Touche, Thierry ;
Thabut, Gabriel ;
Cohen-Solal, Alain .
EUROPEAN HEART JOURNAL, 2006, 27 (24) :3033-3038
[7]   Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[8]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[9]   Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[10]   Contemporary surgical or percutaneous management of severe aortic stenosis in the elderly [J].
Descoutures, Fleur ;
Himbert, Dominique ;
Lepage, Laurent ;
Iung, Bernard ;
Detaint, Delphine ;
Tchetche, Didier ;
Brochet, Eric ;
Castier, Yves ;
Depoix, Jean-Pol ;
Nataf, Patrick ;
Vahanian, Alec .
EUROPEAN HEART JOURNAL, 2008, 29 (11) :1410-1417