Real-time In Vivo Tissue Characterization with Diffuse Reflectance Spectroscopy during Transthoracic Lung Biopsy: A Clinical Feasibility Study

被引:55
|
作者
Spliethoff, Jarich W. [1 ]
Prevoo, Warner [2 ]
Meier, Mark A. J. [2 ]
de Jong, Jeroen [3 ]
Klomp, Houke M. [1 ]
Evers, Daniel J. [1 ]
Sterenborg, Hendricus J. C. M. [1 ,4 ]
Lucassen, Gerald W. [5 ]
Hendriks, Benno H. W. [5 ]
Ruers, Theodoor J. M. [1 ,6 ]
机构
[1] Netherlands Canc Inst, Dept Surg, Amsterdam, Netherlands
[2] Netherlands Canc Inst, Dept Radiol, Amsterdam, Netherlands
[3] Netherlands Canc Inst, Dept Pathol, NL-1066 CX Amsterdam, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Biomed Engn & Phys, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[5] Philips Res, Dept Minimally Invas Healthcare, Eindhoven, Netherlands
[6] Univ Twente, MIRA Inst, POB 217, NL-7500 AE Enschede, Netherlands
关键词
OPTICAL SPECTROSCOPY; BREAST-CANCER; DIAGNOSTIC-ACCURACY; NEEDLE-BIOPSY; OXYGENATION; LESIONS; TOOL;
D O I
10.1158/1078-0432.CCR-15-0807
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study presents the first in vivo real-time tissue characterization during image-guided percutaneous lung biopsies using diffuse reflectance spectroscopy (DRS) sensing at the tip of a biopsy needle with integrated optical fibers. Experimental Design: Tissues from 21 consented patients undergoing lung cancer surgery were measured intraoperatively using the fiber-optic platform capable of assessing various physical tissue properties highly correlated to tissue architecture and composition. In addition, the method was tested for clinical use by performing DRS tissue sensing during 11 routine biopsy procedures in patients with suspected lung cancer. Results: We found that water content and scattering amplitude are the primary discriminators for the transition from healthy lung tissue to tumor tissue and that the reliability of these para-meters is not affected by the amount of blood at the needle tip. In the 21 patients measured intraoperatively, the water-to-scattering ratio yielded a 56% to 81% contrast difference between tumor and surrounding tissue. Analysis of the 11 image-guided lung biopsy procedures showed that the tissue diagnosis derived from DRS was diagnostically discriminant in each clinical case. Conclusions: DRS tissue sensing integrated into a biopsy needle may be a powerful new tool for biopsy guidance that can be readily used in routine diagnostic lung biopsy procedures. This approach may not only help to increase the successful biopsy yield for histopathologic analysis, but may also allow specific sampling of vital tumor tissue for genetic profiling. (C)2015 AACR.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 50 条
  • [1] Diffuse reflectance spectroscopy as a tool for real-time tissue assessment during colorectal cancer surgery
    Baltussen, Elisabeth J. M.
    Snaebjornsson, Petur
    de Koning, Susan G. Brouwer
    Sterenborg, Henricus J. C. M.
    Aalbers, Arend G. J.
    Kok, Niels
    Beets, Geerard L.
    Hendriks, Benno H. W.
    Kuhlmann, Koert F. D.
    Ruers, Theo J. M.
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (10)
  • [2] In vivo Characterization of Epileptic Tissue with Time-Dependent, Diffuse Reflectance Spectroscopy
    Yadav, Nitin
    Oh, Sanghoon
    Bhatia, Sanjeev
    Ragheb, John
    Jayakar, Prasanna
    Duchowny, Michael
    Lin, Wei-Chiang
    26TH SOUTHERN BIOMEDICAL ENGINEERING CONFERENCE: SBEC 2010, 2010, 32 : 105 - +
  • [3] Real-Time In Vivo Characterization of Primary Liver Tumors With Diffuse Optical Spectroscopy During Percutaneous Needle Interventions Feasibility Study in Woodchucks
    Nachabe, Rami
    Hendriks, Benno H. W.
    Schierling, Ross
    Hales, Jasmine
    Racadio, Judy M.
    Rottenberg, Sven
    Ruers, Theo J. M.
    Babic, Drazenko
    Racadio, John M.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (07) : 443 - 448
  • [4] Towards the use of diffuse reflectance spectroscopy for real-time in vivo detection of breast cancer during surgery
    Lisanne L. de Boer
    Torre M. Bydlon
    Frederieke van Duijnhoven
    Marie-Jeanne T. F. D. Vranken Peeters
    Claudette E. Loo
    Gonneke A. O. Winter-Warnars
    Joyce Sanders
    Henricus J. C. M. Sterenborg
    Benno H. W. Hendriks
    Theo J. M. Ruers
    Journal of Translational Medicine, 16
  • [5] Towards the use of diffuse reflectance spectroscopy for real-time in vivo detection of breast cancer during surgery
    de Boer, Lisanne L.
    Bydlon, Torre M.
    van Duijnhoven, Frederieke
    Peeters, Marie-Jeanne T. F. D. Vranken
    Loo, Claudette E.
    Winter-Warnars, Gonneke A. O.
    Sanders, Joyce
    Sterenborg, Henricus J. C. M.
    Hendriks, Benno H. W.
    Ruers, Theo J. M.
    JOURNAL OF TRANSLATIONAL MEDICINE, 2018, 16
  • [6] Diffuse reflectance spectroscopy for colorectal cancer surgical guidance: towards real-time tissue characterization and new biomarkers
    Nogueira, Marcelo Saito
    Maryam, Siddra
    Amissah, Michael
    Killeen, Shane
    O'Riordain, Micheal
    Andersson-Engels, Stefan
    ANALYST, 2023, 149 (01) : 88 - 99
  • [7] REAL-TIME MONITORING OF THERMAL DAMAGE IN EX VIVO TISSUES USING DIFFUSE REFLECTANCE SPECTROSCOPY
    Nagarajan, Vivek Krishna
    Yu, Bing
    LASERS IN SURGERY AND MEDICINE, 2015, 47 : 12 - 12
  • [8] Multiexcitation fluorescence and reflectance spectroscopy as a real time guide to biopsy in vivo
    Müller, MG
    Georgakoudi, I
    Wax, A
    Dasari, R
    Jost, C
    Wallace, M
    Feld, MS
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING VIII, 2001, 4261 : 114 - 121
  • [9] Clinical feasibility of diffuse speckle contrast analysis for real-time tissue perfusion monitoring
    Awopetu, Ayoola, I
    Gohel, Manjit S.
    Sadat, Umar
    Hayes, Paul D.
    INTERNATIONAL ANGIOLOGY, 2022, 41 (01) : 82 - 89
  • [10] Diffuse reflectance spectroscopy: toward real-time quantification of steatosis in liver
    Evers, Daniel J.
    Westerkamp, Andrie C.
    Spliethoff, Jarich W.
    Pully, Vishnu V.
    Hompes, Daphne
    Hendriks, Benno H. W.
    Prevoo, Warner
    van Velthuysen, Marie-Louise F.
    Porte, Robert J.
    Ruers, Theo J. M.
    TRANSPLANT INTERNATIONAL, 2015, 28 (04) : 465 - 474