Development of a tactile sensor system (tactile warmth compared with PVDF sensor output)

被引:0
作者
Tanaka, Yoshihiro [1 ]
Tanaka, Mami [2 ]
Chonan, Seiji [3 ]
机构
[1] Nagoya Inst Technol, Dept Mech Engn, Showa Ku, Gokiso Cho, Nagoya, Aichi 4668555, Japan
[2] Tohoku Univ, Grad Sch Engn, Dept Bioengn & Robot, Sendai, Miyagi 9808579, Japan
[3] Akita Prefectural Univ, Fac Syst & Sci & Technol, Dept Machine Intelligence & Syst Engn, Akita 0150055, Japan
来源
FUTURE MEDICAL ENGINEERING BASED ON BIONANOTECHNOLOGY, PROCEEDINGS | 2006年
关键词
measurement; sensor system; tactile sensation; PVDF film;
D O I
10.1142/9781860948800_0118
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The purpose of this study is the development of a sensor system for measuring tactile sensation. In this paper, tactile warmth on fabrics is compared with PVDF (Polyvinylidene Fluoride) sensor output. First, warmth on each sample is collected through a questionnaire based on the paired comparison semantic differential method. Furthermore, human motion for the evaluation of tactile warmth and contact pressure applied to an object are investigated. Next, a sensor using the pyroelectric effect of a PVDF film is fabricated. The surface of the sensor is heated through temperature control. Then, the sensor is moved and contacted with a measurement object in order to collect pyroelectric output voltage. For the means of driving the sensor system, trajectory control of the contact pressure is introduced on the basis of the results of the examination of human motion. Finally, the measurement using the sensor system is carried out on the samples. Comparison with the results shows that the PVDF sensor system is useful for the evaluation of tactile warmth.
引用
收藏
页码:1095 / +
页数:2
相关论文
共 6 条
[1]   Piezoelectric and pyroelectric transient signal analysis for detection of the temperature of a contact object for robotic tactile sensing [J].
Dargahi, J .
SENSORS AND ACTUATORS A-PHYSICAL, 1998, 71 (1-2) :89-97
[2]  
Kawabata S., 1980, The Standardization and Analysis of Hand Evaluation, V2nd
[3]  
Lederman SJ, 1998, CLIN DEV MED, P16
[4]   New tactile sensor chip with silicone rubber cover [J].
Leineweber, M ;
Pelz, G ;
Schmidt, M ;
Kappert, H ;
Zimmer, G .
SENSORS AND ACTUATORS A-PHYSICAL, 2000, 84 (03) :236-245
[5]   Rating and valuation of human haptic sensation [J].
Tanaka, M ;
Numazawa, Y .
INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2004, 19 (1-4) :573-579
[6]  
TANAKA M, 2002, JSAEM STUDIES APPL E, V12, P53