Transient analysis of single stage GM type double inlet pulse tube cryocooler

被引:4
作者
Gujarati, P. B. [1 ]
Desai, K. P. [1 ]
Naik, H. B. [1 ]
Atrey, M. D. [2 ]
机构
[1] SV Natl Inst Technol, Surat 395007, India
[2] Indian Inst Technol, Bombay 400076, Maharashtra, India
来源
ADVANCES IN CRYOGENIC ENGINEERING | 2015年 / 101卷
关键词
NUMERICAL-SIMULATION; REFRIGERATOR; FLOW;
D O I
10.1088/1757-899X/101/1/012033
中图分类号
O414.1 [热力学];
学科分类号
摘要
Transient analysis of single stage GM type double inlet pulse tube cryocooler is carried out using a one dimensional numerical model based on real gas properties of helium. The model solves continuity, momentum and energy equation for gas and solid to analyse the physical process occurring inside of the pulse tube cryocooler. Finite volume method is applied to discretize the governing equations with realistic initial and boundary conditions. Input data required for solving the model are the design data and operating parameters viz. pressure waveform from the compressor, regenerator matrix data, and system geometry including pulse tube, regenerator size and operating frequency for pulse tube cryocooler. The model investigates the effect of orifice opening, double inlet opening, pressure ratio, system geometry on no load temperature and refrigeration power at various temperatures for different charging pressure. The results are compared with experimental data and reasonable agreement is observed. The model can further be extended for designing two stage pulse tube cryocooler.
引用
收藏
页数:8
相关论文
共 35 条
[31]   Flow loss analysis of a two-stage axially split centrifugal pump with double inlet under different channel designs [J].
Osman, Majeed Koranteng ;
Wang, Wenjie ;
Yuan, Jianping ;
Zhao, Jiantao ;
Wang, Yiyun ;
Liu, Jun .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2019, 233 (15) :5316-5328
[32]   ANALYSIS OF FIV CHARACTERISTICS ON A COAXIAL DOUBLE-TUBE TYPE HOT GAS DUCT FOR THE VHTR [J].
Song, Kee-nam ;
Kim, Yong-wan ;
Park, S-C .
ICONE 17: PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 1, 2009, :779-785
[33]   Analysis of nozzle designs on zoned and staged double P-type gas-fired radiant tube [J].
Xu, Qian ;
Feng, Junxiao .
APPLIED THERMAL ENGINEERING, 2017, 114 :44-50
[34]   Experimental evaluation of the performance of two-stage hot cascade type vortex tube when the inlet pressure, length (L)/diameter (D) ratio and number of nozzles are varied [J].
Kumar, R. Madhu ;
Sudheer, N. V. V. S. ;
Babu, Katam Ganesh .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2019, :936-941
[35]   Design and optimization analysis of a new double-layer tube type heat exchanger for lead-bismuth reactors [J].
Qi, JingWen ;
Ai, QingSong ;
Zhao, PengCheng ;
Yang, Junkang ;
Wang, GuiMei .
FRONTIERS IN ENERGY RESEARCH, 2024, 12