Near-patient testing of blood glucose using the Bayer Rapidlab 860 analyser in a regional neonatal unit

被引:10
作者
Peet, AC
Kennedy, DM
Hocking, MD
Ewer, AK
机构
[1] Birmingham Womens Hosp, Reg Neonatal Unit, Birmingham B15 2TG, W Midlands, England
[2] Birmingham Womens Hosp, Clin Chem Lab, Birmingham B15 2TG, W Midlands, England
关键词
D O I
10.1258/000456302320314520
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background We evaluated the use of the glucose biosensor on the Bayer Rapidlab 860 (BR 860) blood gas analyser for neonates and compared it with two laboratory-based methods for measuring blood glucose using the Yellow Springs Instruments 2300 STAT PLUS (YSI) analyser and the Vitros 750 XRC (Vitros) analyser. Methods Arterial, capillary and venous blood samples were taken from 50 neonates, and blood glucose was measured using all three instruments. Blood pH, PO2 haematocrit and plasma albumin data were also recorded. The effect of varying the degree of haemolysis and the haematocrit was examined using cord blood samples prepared in vitro. Results Day-to-day imprecision of the BR 860 was 4.90% at a mean glucose concentration of 2.55 mmol/L (n = 60), compared with 3.03% at 2.33 mmol/L (n = 34) for the YSI and 2.64% at 3.52 mmol/L for the Vitros (n = 59). Using Deming regression, the BR 860 results correlated well with results produced on both the YSI (r = 0.962, n = 47, P < 0.001) and Vitros (r = 0.980, n = 46, P < 0.001) analysers. Bland-Altman difference plots showed that he BR 860 had a mean of the differences of 0.30 mmol/L compared with the YSI and 0.09 mmol/L compared with the Vitros. The Bland-Altman standard deviation of the differences was 0.46 mmol/L when the BR 860 was compared with the YSI and 0.31 mmol/L when the BR 860 was compared with the Vitros. No significant correlation was found between the BR 860 glucose measurements and haematocrit, degree of sample haemolysis, plasma albumin, blood pH or PO2, Conclusions The BR 860 analyser provides neonatal blood glucose measurements in the clinical setting of a neonatal unit that compare well with results obtained using laboratory-based methods.
引用
收藏
页码:502 / 508
页数:7
相关论文
共 18 条
[1]  
BATKI AD, MDA9710
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
CHAN AYW, 1989, CLIN CHEM, V35, P315
[4]   CLINICAL-APPLICATION OF A NEW GLUCOSE ANALYZER IN THE NEONATAL INTENSIVE-CARE UNIT - COMPARISON WITH OTHER METHODS [J].
CONRAD, PD ;
SPARKS, JW ;
OSBERG, I ;
ABRAMS, L ;
HAY, WW .
JOURNAL OF PEDIATRICS, 1989, 114 (02) :281-287
[5]  
Deming W.E., 1943, STAT ADJUSTMENT DATA, P184
[6]  
DESHPANDE SA, 1996, ARCH DIS CHILD, V75, P202
[7]  
HAMEED M, 1996, BR J INTENS CARE, V6, P115
[8]   BLOOD-GLUCOSE DETERMINATION IN INFANTS AND CHILDREN - REFLECTANCE METER ENZYME TEST STRIP SYSTEM [J].
HAWORTH, JC ;
VANWOERT, M ;
DILLING, LA .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1972, 123 (05) :469-&
[9]   COMPARISON OF VARIOUS METHODS OF BLOOD-SUGAR SCREENING IN NEWBORN-INFANTS [J].
HERRERA, AJ ;
HSIANG, YH .
JOURNAL OF PEDIATRICS, 1983, 102 (05) :769-772
[10]   A COMPARISON OF CHROMOGEN TEST STRIP (CHEMSTRIP BG) AND SERUM GLUCOSE VALUES IN NEWBORNS [J].
HOLTROP, PC ;
MADISON, KA ;
KIECHLE, FL ;
KARCHER, RE ;
BATTON, DG .
AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1990, 144 (02) :183-185