Sensor reduction of a PV-grid tied system with tripartite control based on LCL filter

被引:2
作者
Kumari, Khushboo [1 ]
Jain, Amit Kumar [1 ]
机构
[1] Indian Inst Technol, Elect Dept, New Delhi 110016, India
关键词
SOLAR PV; INVERTER; INTEGRATION; DESIGN;
D O I
10.1049/esi2.12072
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper deals with a tripartite control based on LCL-filter for a single-stage solar photovoltaic (PV) interconnected three-phase grid-tied system. This work proposes a novel tripartite control for LCL-filter based on sensing capacitor side voltage utilising two sensors. Conventionally, the control algorithm requires six sensors for sensing the inverter-side inductor current, capacitor side voltage, and grid-side inductor current. However, in this work, to execute the tripartite control algorithm, the only voltage across the filter capacitor need to be sensed. The voltage across the filter capacitor estimates inverter-side inductor current and grid-side inductor current. The proposed algorithm offers the advantage/benefit in reducing size, weight, and implemented cost. As an outcome, the reduction in the complexity of the hardware takes place. The implemented system is analysed for parametric variation to ensure the stability and robustness of the system. The system response is observed under digital control delay variation. The proposed method offers a cost-effective solution for meeting grid regulation. The implemented system is extensively tested and validated by simulation in the MATLAB/Simulink platform. The justification of the system is carried out by experimental results obtained from the prototype designed in the laboratory.
引用
收藏
页码:409 / 419
页数:11
相关论文
共 18 条
[1]   Direct power control with common mode voltage reduction of grid-connected three-level NPC inverter [J].
Ben Mahmoud, Zouhaira ;
Hamouda, Mahmoud ;
Khedher, Adel .
IET POWER ELECTRONICS, 2019, 12 (03) :400-409
[2]   Robust nested loop control scheme for LCL-filtered inverter-based DG unit in grid-connected and islanded modes [J].
Buduma, Parusharamulu ;
Panda, Gayadhar .
IET RENEWABLE POWER GENERATION, 2018, 12 (11) :1269-1285
[3]   Active damping of LCL filter at low switching to resonance frequency ratio [J].
Ghoshal, Anirban ;
John, Vinod .
IET POWER ELECTRONICS, 2015, 8 (04) :574-582
[4]   Design methodology of a passive damped modified LCL filter for leakage current reduction in grid-connected transformerless three-phase PV inverters [J].
Giacomini, Julian C. ;
Michels, Leandro ;
Pinheiro, Humberto ;
Rech, Cassiano .
IET RENEWABLE POWER GENERATION, 2017, 11 (14) :1769-1777
[5]   Integration of solar PV into grid using a new UPQC with differential inverter control [J].
Kakkattil Narayanan, Sivarajan ;
Sivarajan, Nirmal ;
Erakkath Abdu, Jasmin ;
Balakrishnan, Jayanand .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (19) :4254-4263
[6]   Multi-pulse AC-DC converter fed SVM controlled NPC inverter based VCIMD [J].
Kant, Piyush ;
Singh, Bhim .
IET POWER ELECTRONICS, 2018, 11 (14) :2204-2214
[7]   Sizing approaches for solar photovoltaic-based microgrids: A comprehensive review [J].
Mathew, Mobi ;
Hossain, Md Shafayet ;
Saha, Sajeeb ;
Mondal, Som ;
Haque, Md Enamul .
IET ENERGY SYSTEMS INTEGRATION, 2022, 4 (01) :1-27
[8]   Passivity-based output admittance shaping of the converter-side current-controlled grid-tied inverter to improve the robustness to the grid impedance [J].
Qian, Qiang ;
Xie, Shaojun ;
Xu, Jinming ;
Bian, Shenyiyang ;
Zhong, Nini .
IET POWER ELECTRONICS, 2020, 13 (10) :1956-1965
[9]   Enhanced control of grid-connected inverters with non-linear inductor in LCL filter [J].
Safamehr, Hossein ;
Najafabadi, Tooraj Abbasian ;
Salmasi, Farzad Rajaei .
IET POWER ELECTRONICS, 2016, 9 (10) :2111-2120
[10]   Iterated extended Kalman filter-based grid synchronisation control of a PV systemInspec keywordsOther keywords [J].
Swain, Sudarshan ;
Subudhi, Bidyadhar .
IET ENERGY SYSTEMS INTEGRATION, 2019, 1 (04) :219-228