Impact of Body Size on Inferior Vena Cava Parameters for Estimating Right Atrial Pressure: A Need for Standardization?

被引:44
|
作者
Taniguchi, Tatsunori [1 ]
Ohtani, Tomohito [1 ]
Nakatani, Satoshi [1 ]
Hayashi, Kenichi [2 ]
Yamaguchi, Osamu [1 ]
Komuro, Issei [3 ]
Sakata, Yasushi [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Cardiovasc Med, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Biomed Stat, Suita, Osaka 5650871, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Cardiovasc Med, Tokyo, Japan
关键词
Inferior vena cava; Right atrial pressure; Two-dimensional imaging; Body surface area; HEART-FAILURE; NONINVASIVE ESTIMATION; RENAL-FUNCTION; SURFACE AREA; ECHOCARDIOGRAPHY; MORTALITY; CHILDREN; ADULTS; INDEX;
D O I
10.1016/j.echo.2015.07.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Inferior vena cava (IVC) diameter and its respiratory change, as determined using echocardiography, are commonly used to assess right atrial pressure (RAP). Despite the widespread use of the IVC approach for RAP assessment, the relations among body surface area (BSA), IVC diameter, and respirophasic change remain unclear. The aim of this study was to investigate the impact of BSA on IVC parameters for predicting elevated RAP. Methods: Ninety consecutive patients undergoing right-heart catheterization or central venous catheter insertion were prospectively included. To investigate the impact of BSA on IVC parameters, patients were divided into higher and lower BSA groups by comparing individual BSA measurements with the median value. Optimal cutoff points of IVC parameters for detecting RAP of >= 10 mm Hg were defined using receiver operating characteristic curves. Results: The median RAP and BSA were 8 mm Hg (range, 1-25 mm Hg) and 1.61 m(2) (range, 1.23-2.22 m(2)), respectively. In all patients, the optimal cutoff point for maximal IVC diameter (IVCDmax) and IVC collapsibility for the detection of RAP > 10 mm Hg were 20 mm and 49.0%, respectively. The optimal cutoff point of IVCDmax for predicting RAP of >= 10 mm Hg was significantly larger in patients with higher BSAs than in those with lower BSAs (21 vs 17 mm, P =.0342). No differences in collapsibility indices were detected between the two groups. IVCDmax was larger in men (1965 vs 17 +/- 5 mm in women, P =.0347) and weakly correlated with BSA (r = 0.35, P =.0007), whereas no relation was found between IVCDmax and age. However, the partial correlation coefficient of the entire cohort demonstrated that only BSA was still associated with IVCDmax after adjusting for age and gender (partial correlation coefficient = 0.32, P =.0020). Conclusions: Body size, measured as BSA, is important to consider when IVC diameter is used to assess RAP. The optimal cutoff point of IVCDmax was 21 mm for patients with larger BSAs and 17 mm for those with smaller BSAs. However, the cutoff point of IVC collapsibility was not influenced by the difference of BSA. (J Am Soc Echocardiogr 2015; 28: 1420-7.)
引用
收藏
页码:1420 / 1427
页数:8
相关论文
共 44 条
  • [41] Leiomyosarcoma of the inferior vena cava extending into the right atriumA rare differential diagnosis of a right atrial tumor with fatal outcomeLeiomyosarkom der V. cava inferior mit Ausdehnung bis in den rechten VorhofSeltene Differentialdiagnose eines rechtsatrialen Tumors mit letalem Ausgang
    U. Lotze
    J. Reponova
    G. Muth
    G. Oltmanns
    H.-C. Reich
    G. Etzrodt
    W.A. Kaiser
    O. Mutschke
    M Ortmann
    D. Stippel
    T. Wahlers
    Herz, 2012, 37 (5) : 573 - 578
  • [42] Right Ventricular End-Diastolic Wall Stress: Does It Impact on Right Atrial Size, and Does It Differ in Right Ventricular Pressure vs Volume Loading Conditions?
    Addetia, Karima
    Sebag, Igal A.
    Marelli, Ariane
    Do, Doan Hoa
    Afilalo, Jon
    Martucci, Guisseppe
    Therrien, Judith
    CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (07) : 858 - 865
  • [43] The Dilated Coronary Sinus: Utility of Coronary Sinus Cross-Sectional Area and Eccentricity Index in Differentiating Right Atrial Pressure Overload from Persistent Left Superior Vena Cava
    Kolski, Brian C.
    Khadivi, Bahram
    Anawati, Mirielle
    Daniels, Lori B.
    DeMaria, Anthony N.
    Blanchard, Daniel G.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2011, 28 (08): : 829 - 832
  • [44] Case report: Inferior vena-cava right atrial anastomotic stenosis after bicaval orthotopic heart transplantation[Présentation de cas : sténose anastomotique auriculaire droite de la veine cave inférieure à la suite d’une transplantation cardiaque orthotopique bicave]
    Eric Jacobsohn
    Michael S. Avidan
    Charles B. Hantler
    Frank Rosemeier
    Charl J. De Wet
    Canadian Journal of Anesthesia, 2006, 53 (10): : 1039 - 1043