Impact of Body Size on Inferior Vena Cava Parameters for Estimating Right Atrial Pressure: A Need for Standardization?

被引:44
|
作者
Taniguchi, Tatsunori [1 ]
Ohtani, Tomohito [1 ]
Nakatani, Satoshi [1 ]
Hayashi, Kenichi [2 ]
Yamaguchi, Osamu [1 ]
Komuro, Issei [3 ]
Sakata, Yasushi [1 ]
机构
[1] Osaka Univ, Grad Sch Med, Dept Cardiovasc Med, Suita, Osaka 5650871, Japan
[2] Osaka Univ, Grad Sch Med, Dept Biomed Stat, Suita, Osaka 5650871, Japan
[3] Univ Tokyo, Grad Sch Med, Dept Cardiovasc Med, Tokyo, Japan
关键词
Inferior vena cava; Right atrial pressure; Two-dimensional imaging; Body surface area; HEART-FAILURE; NONINVASIVE ESTIMATION; RENAL-FUNCTION; SURFACE AREA; ECHOCARDIOGRAPHY; MORTALITY; CHILDREN; ADULTS; INDEX;
D O I
10.1016/j.echo.2015.07.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Inferior vena cava (IVC) diameter and its respiratory change, as determined using echocardiography, are commonly used to assess right atrial pressure (RAP). Despite the widespread use of the IVC approach for RAP assessment, the relations among body surface area (BSA), IVC diameter, and respirophasic change remain unclear. The aim of this study was to investigate the impact of BSA on IVC parameters for predicting elevated RAP. Methods: Ninety consecutive patients undergoing right-heart catheterization or central venous catheter insertion were prospectively included. To investigate the impact of BSA on IVC parameters, patients were divided into higher and lower BSA groups by comparing individual BSA measurements with the median value. Optimal cutoff points of IVC parameters for detecting RAP of >= 10 mm Hg were defined using receiver operating characteristic curves. Results: The median RAP and BSA were 8 mm Hg (range, 1-25 mm Hg) and 1.61 m(2) (range, 1.23-2.22 m(2)), respectively. In all patients, the optimal cutoff point for maximal IVC diameter (IVCDmax) and IVC collapsibility for the detection of RAP > 10 mm Hg were 20 mm and 49.0%, respectively. The optimal cutoff point of IVCDmax for predicting RAP of >= 10 mm Hg was significantly larger in patients with higher BSAs than in those with lower BSAs (21 vs 17 mm, P =.0342). No differences in collapsibility indices were detected between the two groups. IVCDmax was larger in men (1965 vs 17 +/- 5 mm in women, P =.0347) and weakly correlated with BSA (r = 0.35, P =.0007), whereas no relation was found between IVCDmax and age. However, the partial correlation coefficient of the entire cohort demonstrated that only BSA was still associated with IVCDmax after adjusting for age and gender (partial correlation coefficient = 0.32, P =.0020). Conclusions: Body size, measured as BSA, is important to consider when IVC diameter is used to assess RAP. The optimal cutoff point of IVCDmax was 21 mm for patients with larger BSAs and 17 mm for those with smaller BSAs. However, the cutoff point of IVC collapsibility was not influenced by the difference of BSA. (J Am Soc Echocardiogr 2015; 28: 1420-7.)
引用
收藏
页码:1420 / 1427
页数:8
相关论文
共 44 条
  • [21] Transcatheter Arterial Chemoembolization for Advanced Hepatocellular Carcinoma with Inferior Vena Cava and Right Atrial Tumors
    M. C. Chern
    V. P. Chuang
    T. Cheng
    Z. H. Lin
    Y. M. Lin
    CardioVascular and Interventional Radiology, 2008, 31 : 735 - 744
  • [22] PERMANENT PACEMAKER POSITIONING VIA THE INFERIOR VENA-CAVA IN A CASE OF SINGLE VENTRICLE WITH LOSS OF RIGHT ATRIAL VENA-CAVA CONTINUITY
    WEST, JNW
    SHEARMANN, CP
    GAMMAGE, MD
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (08): : 1753 - 1755
  • [23] Discrepancy between inferior vena cava and right atrial oxygen saturations as a sign of ischemia in the mesenteric circulation
    Lyons, Kristopher S.
    Strange, John
    Clarke, Robert C. N.
    JOURNAL OF CRITICAL CARE, 2008, 23 (03) : 357 - 358
  • [24] Accuracy of right atrial pressure estimation using a multi-parameter approach derived from inferior vena cava semi-automated edge-tracking echocardiography: a pilot study in patients with cardiovascular disorders
    Albani, Stefano
    Pinamonti, Bruno
    Giovinazzo, Tatiana
    de Scordilli, Marco
    Fabris, Enrico
    Stolfo, Davide
    Perkan, Andrea
    Gregorio, Caterina
    Barbati, Giulia
    Geri, Pietro
    Confalonieri, Marco
    Lo Giudice, Francesco
    Aquaro, Giovanni D.
    Pasquero, Paolo
    Porta, Massimo
    Sinagra, Gianfranco
    Mesin, Luca
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (07) : 1213 - 1225
  • [25] Dynamics of nitroglycerin-induced changes in vena cava flows and right atrial pressure
    Tkachenko, BI
    Evlakhov, VI
    Poyasov, IZ
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2003, 136 (02) : 107 - 109
  • [26] Dynamics of Nitroglycerin-Induced Changes in Vena Cava Flows and Right Atrial Pressure
    B. I. Tkachenko
    V. I. Evlakhov
    I. Z. Poyasov
    Bulletin of Experimental Biology and Medicine, 2003, 136 : 107 - 109
  • [27] Leiomyosarcoma of the inferior vena cava extending into the right atrium. A rare differential diagnosis of a right atrial tumor with fatal outcome
    Lotze, U.
    Reponova, J.
    Muth, G.
    Oltmanns, G.
    Reich, H. -C.
    Etzrodt, G.
    Kaiser, W. A.
    Mutschke, O.
    Ortmann, M.
    Stippel, D.
    Wahlers, T.
    HERZ, 2012, 37 (05) : 573 - 578
  • [28] Continuous Flow from Inferior Vena Cava into the Right Atrium Predicts Normal Central Venous Pressure
    Ranjan, Rupesh
    Ipek, Esra Gucuk
    Toroghi, Hesam Mostafavi
    Schiller, Nelson B.
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2018, 12 (04) : 133 - 136
  • [29] Calcified inferior vena cava and right atrial myxoma in an 18-month-old male A case report
    Chen, Renwei
    Deng, Xicheng
    Luo, Jinwen
    Huang, Peng
    MEDICINE, 2018, 97 (25)
  • [30] Limited value of end-expiratory inferior vena cava diameter to predict fluid responsiveness impact of intra-abdominal pressure
    Vieillard-Baron, Antoine
    Evrard, Bruno
    Repesse, Xavier
    Maizel, Julien
    Jacob, Christophe
    Goudelin, Marine
    Charron, Cyril
    Prat, Gwenael
    Slama, Michel
    Geri, Guillaume
    Vignon, Philippe
    INTENSIVE CARE MEDICINE, 2018, 44 (02) : 197 - 203